  "id": 3587,
  "url": "https://nnemf.org/research/3587-theoretical-and-experimental-investigation-of-the-relationship-among",
  "title": "Theoretical and experimental investigation of the relationship among SAR, tissues and radio frequencies in MRI.",
  "authors": [
    "Chunsheng Wang",
    "Gary X Shen",
    "Jin Yuan",
    "Peng Qu",
    "Bing Wu"
  ],
  "journal": "Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)",
  "year": "2005",
  "doi": "10.1016/s1120-1797(05)80020-1",
  "pmid": "18348846",
  "abstract": "The specific absorption rates (SAR) of three tissues (muscle, brain, bone) are investigated both theoretically and experimentally for MRI at the first time. Finite difference time domain (FDTD) analysis is used to simulate the average SAR of three tissues at three magnetic field strengths (0.5 T, 1.5 T, 3T). Simulations show that the SAR of muscle, brain and bone increase 7.49 folds, 10.87 folds and 12.92 folds respectively when the magnetic field strength increases from 0.5 T to 3 T. Experiments are carried out to measure SRAS of different phantoms which simulate the three human tissues at 1.5T and 3T. The experiment results agree with the simulation data very well and within only 11% difference.",
  "effect": "unclear",
  "evidence": "low",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "unclear",
    "evidenceLabel": "Low",
    "population": "—",
    "sampleSize": "—",
    "exposure": "MRI",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "Using FDTD simulations, average SAR in muscle, brain, and bone increased by 7.49-fold, 10.87-fold, and 12.92-fold, respectively, when magnetic field strength increased from 0.5 T to 3 T. Phantom experiments at 1.5 T and 3 T agreed with simulations within 11% difference.",
    "outcomes": [
      "Specific absorption rate (SAR) in muscle",
      "brain",
      "and bone (simulated and phantom-measured)",
      "Relationship between SAR and MRI magnetic field strength (0.5 T",
      "1.5 T",
      "3 T)"
    ],
    "limitations": [
      "Radiofrequency (MHz) not reported in abstract",
      "SAR values (e.g.",
      "W/kg) not reported",
      "only fold-changes are provided",
      "Experimental measurements were performed on phantoms rather than human tissues",
      "Only three tissue types and limited field strengths (0.5 T",
      "1.5 T",
      "3 T) described"
    ],
    "keywords": [
      "MRI",
      "specific absorption rate",
      "SAR",
      "FDTD",
      "phantom",
      "muscle",
      "brain",
      "bone",
      "magnetic field strength",
      "0.5 T",
      "1.5 T",
      "3 T"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": null,\n    \"source\": \"MRI\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Specific absorption rate (SAR) in muscle, brain, and bone (simulated and phantom-measured)\",\n    \"Relationship between SAR and MRI magnetic field strength (0.5 T, 1.5 T, 3 T)\"\n  ],\n  \"main_findings\": \"Using FDTD simulations, average SAR in muscle, brain, and bone increased by 7.49-fold, 10.87-fold, and 12.92-fold, respectively, when magnetic field strength increased from 0.5 T to 3 T. Phantom experiments at 1.5 T and 3 T agreed with simulations within 11% difference.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"Radiofrequency (MHz) not reported in abstract\",\n    \"SAR values (e.g., W/kg) not reported; only fold-changes are provided\",\n    \"Experimental measurements were performed on phantoms rather than human tissues\",\n    \"Only three tissue types and limited field strengths (0.5 T, 1.5 T, 3 T) described\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"MRI\",\n    \"specific absorption rate\",\n    \"SAR\",\n    \"FDTD\",\n    \"phantom\",\n    \"muscle\",\n    \"brain\",\n    \"bone\",\n    \"magnetic field strength\",\n    \"0.5 T\",\n    \"1.5 T\",\n    \"3 T\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/18348846/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3587",
  "updated": "2026-02-13 07:29:04"
}