  "id": 3610,
  "url": "https://nnemf.org/research/3610-a-portable-low-power-wireless-two-lead-ekg",
  "title": "A portable, low-power, wireless two-lead EKG system.",
  "authors": [
    "Thaddeus R F Fulford-Jones",
    "Gu-Yeon Wei",
    "Matt Welsh"
  ],
  "journal": "Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference",
  "year": "2004",
  "doi": "10.1109/iembs.2004.1403627",
  "pmid": "17272147",
  "abstract": "Sensor devices (\"motes\") which integrate an embedded microprocessor, low-power radio and a limited amount of storage have the potential to significantly enhance the provision of emergency medical care. Wearable vital sign sensors can wirelessly monitor patient condition, alerting healthcare providers to changes in status while simultaneously delivering data to a backend archival system for longer-term storage. As part of the CodeBlue initiative at Harvard University, we previously developed a mote-based pulse oximetry module which gathers data from a noninvasive finger sensor and transmits it wirelessly to a base station. To expand the capabilities of the mote for healthcare applications we now introduce EKG on Mica2, the first custom-designed electrocardiograph sensor board to interface with this platform. We additionally present VitalEKG, a collection of software components which allow the capture and wireless transmission of heart activity traces. We present preliminary test results which validate our approach and suggest the feasibility of future enhancements.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "RF",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "The authors describe a custom-designed electrocardiograph sensor board (EKG on Mica2) and accompanying software (VitalEKG) to capture and wirelessly transmit heart activity traces. Preliminary test results are reported to validate the approach and suggest feasibility of future enhancements.",
    "outcomes": [
      "Feasibility of a portable",
      "low-power wireless two-lead EKG system",
      "Wireless capture and transmission of EKG/heart activity traces",
      "Preliminary test validation of the approach"
    ],
    "limitations": [
      "No EMF exposure parameters (e.g.",
      "frequency",
      "power",
      "SAR) are provided in the abstract.",
      "No health effects assessment is described",
      "the focus is on device design and feasibility.",
      "Sample size and testing conditions are not reported in the abstract."
    ],
    "keywords": [
      "wireless",
      "low-power radio",
      "motes",
      "wearable sensors",
      "EKG",
      "electrocardiograph",
      "CodeBlue",
      "Mica2",
      "VitalEKG",
      "emergency medical care"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": null,\n    \"source\": \"low-power radio (wireless transmission)\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Feasibility of a portable, low-power wireless two-lead EKG system\",\n    \"Wireless capture and transmission of EKG/heart activity traces\",\n    \"Preliminary test validation of the approach\"\n  ],\n  \"main_findings\": \"The authors describe a custom-designed electrocardiograph sensor board (EKG on Mica2) and accompanying software (VitalEKG) to capture and wirelessly transmit heart activity traces. Preliminary test results are reported to validate the approach and suggest feasibility of future enhancements.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No EMF exposure parameters (e.g., frequency, power, SAR) are provided in the abstract.\",\n    \"No health effects assessment is described; the focus is on device design and feasibility.\",\n    \"Sample size and testing conditions are not reported in the abstract.\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"wireless\",\n    \"low-power radio\",\n    \"motes\",\n    \"wearable sensors\",\n    \"EKG\",\n    \"electrocardiograph\",\n    \"CodeBlue\",\n    \"Mica2\",\n    \"VitalEKG\",\n    \"emergency medical care\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/17272147/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3610",
  "updated": "2026-02-13 07:30:50"
}