Study of the effects of 50 Hz homogeneous magnetic field on apoptosis and proliferation of SNU cells in vitro.

Hongyong Guo, Mo Zheng, Lingxiao Xing, Ying Li, Manling Ge, Xianghong Zhang, Weili Yan

PAPERpubmedConference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference2004In vitro studyEffect: mixedEvidence: Low

Abstract

The biological effects of magnetic field on SNU (human low differentiated gastric adenocarcinoma cell line) cells are studied in this paper. SNU cells were randomly divided into control groups and four treatment groups, the treatment groups were respectively irradiated by 50 Hz ferromagnetic field (0.097 T) 5 min., 30 min., 60 min., and 120 min. We observed the effects on proliferation and apoptosis of SNU cells after the treatment of magnetic field by flow cytometric (FCM) DNA analysis and electron microscope observation. The apoptosis rate in treatment groups are 4.75% +/- 1.24%, 6.50% +/- 0.61%, 9.20% +/- 1.76% and 6.26% +/- 2.95% respectively and significantly higher than that in control group. In the irradiation time range from 5 min to 60 min, there is a significant time-depended response correlation of apoptosis rate( r = 0.97, P < 0.01), but FCM results showed that the effects of 50 Hz homogeneous ferromagnetic field on the proliferation and distribution of cell cycle of SNU cells is not significant. We concluded that irradiation of 50 Hz homogeneous ferromagnetic field could promote apoptosis of SNU cells.

AI evidence extraction

At a glance
Study type
In vitro study
Effect direction
mixed
Population
SNU (human low differentiated gastric adenocarcinoma cell line) cells
Sample size
—
Exposure
ELF · 0.05 MHz · 5, 30, 60, or 120 min
Evidence strength
Low
Confidence: 86% · Peer-reviewed: yes

Main findings

SNU cells exposed to a 50 Hz homogeneous ferromagnetic field (0.097 T) for 5–120 minutes had significantly higher apoptosis rates than controls, with a time-dependent increase from 5 to 60 minutes (r=0.97, P<0.01). Flow cytometry indicated no significant effects on proliferation or cell-cycle distribution.

Outcomes measured

  • Apoptosis rate
  • Cell proliferation
  • Cell cycle distribution

Limitations

  • Sample size not reported in abstract
  • In vitro cell-line study
  • generalizability to humans not addressed
  • Exposure described as 0.097 T ferromagnetic field
  • dosimetry beyond field strength not provided
  • Only short-term exposures (minutes) assessed
View raw extracted JSON
{
  "study_type": "in_vitro",
  "exposure": {
    "band": "ELF",
    "source": null,
    "frequency_mhz": 0.05,
    "sar_wkg": null,
    "duration": "5, 30, 60, or 120 min"
  },
  "population": "SNU (human low differentiated gastric adenocarcinoma cell line) cells",
  "sample_size": null,
  "outcomes": [
    "Apoptosis rate",
    "Cell proliferation",
    "Cell cycle distribution"
  ],
  "main_findings": "SNU cells exposed to a 50 Hz homogeneous ferromagnetic field (0.097 T) for 5–120 minutes had significantly higher apoptosis rates than controls, with a time-dependent increase from 5 to 60 minutes (r=0.97, P<0.01). Flow cytometry indicated no significant effects on proliferation or cell-cycle distribution.",
  "effect_direction": "mixed",
  "limitations": [
    "Sample size not reported in abstract",
    "In vitro cell-line study; generalizability to humans not addressed",
    "Exposure described as 0.097 T ferromagnetic field; dosimetry beyond field strength not provided",
    "Only short-term exposures (minutes) assessed"
  ],
  "evidence_strength": "low",
  "confidence": 0.86,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "50 Hz",
    "ELF magnetic field",
    "homogeneous magnetic field",
    "ferromagnetic field",
    "0.097 T",
    "SNU cells",
    "gastric adenocarcinoma cell line",
    "apoptosis",
    "proliferation",
    "cell cycle",
    "flow cytometry",
    "electron microscopy"
  ],
  "suggested_hubs": [
    {
      "slug": "elf-emf",
      "weight": 0.9,
      "reason": "Study examines biological effects of 50 Hz magnetic field exposure."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 3618

Study of the effects of 50 Hz homogeneous magnetic field on apoptosis and proliferation of SNU cells in vitro. · Non-native EMF