Share

Uniaxial alignment of the smallest diamagnetic susceptibility axis using time-dependent magnetic fields.

Tsunehisa Kimura, Masashi Yoshino, Tsutomu Yamane, Masafumi Yamato, Masayuki Tobita

PAPERpubmedLangmuir : the ACS journal of surfaces and colloids2004engineeringEffect: unclearEvidence: Insufficient

Abstract

A diamagnetic particle with magnetic susceptibilities chi3 < chi2 = chi1 < 0 was subjected to a rotating magnetic field to obtain an alignment of the chi3 axis (the smallest susceptibility axis) in the direction perpendicular to the plane of the rotating magnetic field. A polymer short fiber, whose fiber axis coincides with the chi3 axis, was suspended in a fluid with the same density, and then a rotating magnetic field generated by a rotation of a pair of permanent magnets was applied. The fiber axis, rotating following the applied field, finally ended up with an alignment perpendicular to the plane of the rotating magnetic field. The experimental data on the time course of the alignment was in good agreement with the numerical calculation based on the equation of rotation.

AI evidence extraction

At a glance
Study type
engineering
Effect direction
unclear
Population
—
Sample size
—
Exposure
rotating magnetic field (pair of permanent magnets)
Evidence strength
Insufficient
Confidence: 74% · Peer-reviewed: yes

Main findings

A polymer short fiber (with its axis coinciding with the smallest diamagnetic susceptibility axis, chi3) suspended in a density-matched fluid aligned perpendicular to the plane of an applied rotating magnetic field generated by rotating permanent magnets. The measured time course of alignment agreed well with numerical calculations based on an equation of rotation.

Outcomes measured

  • Alignment of diamagnetic particle/fiber axis (chi3 axis) relative to rotating magnetic field plane
  • Time course of alignment compared with numerical calculation
View raw extracted JSON
{
  "study_type": "engineering",
  "exposure": {
    "band": null,
    "source": "rotating magnetic field (pair of permanent magnets)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "Alignment of diamagnetic particle/fiber axis (chi3 axis) relative to rotating magnetic field plane",
    "Time course of alignment compared with numerical calculation"
  ],
  "main_findings": "A polymer short fiber (with its axis coinciding with the smallest diamagnetic susceptibility axis, chi3) suspended in a density-matched fluid aligned perpendicular to the plane of an applied rotating magnetic field generated by rotating permanent magnets. The measured time course of alignment agreed well with numerical calculations based on an equation of rotation.",
  "effect_direction": "unclear",
  "limitations": [],
  "evidence_strength": "insufficient",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "diamagnetic susceptibility",
    "uniaxial alignment",
    "rotating magnetic field",
    "permanent magnets",
    "polymer short fiber",
    "numerical calculation",
    "equation of rotation"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 3632

Uniaxial alignment of the smallest diamagnetic susceptibility axis using time-dependent magnetic fields. · Non-native EMF