  "id": 3633,
  "url": "https://nnemf.org/research/3633-ensuring-transmurality-using-irrigated-radiofrequency-modified-maze-in",
  "title": "Ensuring transmurality using irrigated radiofrequency modified maze in surgery for atrial fibrillation--a simple and effective way.",
  "authors": [
    "James W W Wong"
  ],
  "journal": "Heart, lung & circulation",
  "year": "2004",
  "doi": "10.1016/j.hlc.2004.03.017",
  "pmid": "16352212",
  "abstract": "Transmural lesions are ensured with the cut and sew technique and with bipolar delivery of radiofrequency (RF) energy [Ann. Thorac. Surg. 74 (2002) 2210]. Unipolar sources of energy such as radiofrequency and microwave do not guarantee transmurality and may require intraoperative testing to evaluate complete lesion depth. Transmural lesions are generally effective electrophysiological lesions and are desirable as it does not allow atrial fibrillation (AF) breakthrough or development of atrial flutter in most instances. We describe a simple and effective way of ensuring transmurality using irrigated radiofrequency in the modified maze surgery for AF.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "other",
    "studyTypeLabel": "Other",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "microwave",
    "confidencePct": "62",
    "peerReviewed": "yes",
    "mainFindings": "The abstract states that unipolar energy sources (including radiofrequency and microwave) do not guarantee transmurality and may require intraoperative testing. It describes a simple and effective method to ensure transmurality using irrigated radiofrequency in modified maze surgery for atrial fibrillation.",
    "outcomes": [
      "transmural lesion creation (lesion depth/completeness)",
      "atrial fibrillation breakthrough",
      "atrial flutter development"
    ],
    "limitations": [
      "No quantitative results are provided in the abstract.",
      "No sample size or patient characteristics are reported.",
      "Study design details are not stated."
    ],
    "keywords": [
      "radiofrequency",
      "irrigated radiofrequency",
      "modified maze",
      "atrial fibrillation",
      "transmurality",
      "surgery",
      "lesion depth"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"other\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"surgical radiofrequency ablation (irrigated RF)\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"transmural lesion creation (lesion depth/completeness)\",\n    \"atrial fibrillation breakthrough\",\n    \"atrial flutter development\"\n  ],\n  \"main_findings\": \"The abstract states that unipolar energy sources (including radiofrequency and microwave) do not guarantee transmurality and may require intraoperative testing. It describes a simple and effective method to ensure transmurality using irrigated radiofrequency in modified maze surgery for atrial fibrillation.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No quantitative results are provided in the abstract.\",\n    \"No sample size or patient characteristics are reported.\",\n    \"Study design details are not stated.\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.62,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"radiofrequency\",\n    \"irrigated radiofrequency\",\n    \"modified maze\",\n    \"atrial fibrillation\",\n    \"transmurality\",\n    \"surgery\",\n    \"lesion depth\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/16352212/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3633",
  "updated": "2026-02-13 07:31:13"
}