Abstract

BACKGROUND: Chronic hip pain is often a debilitating problem and many patients are not good surgical candidates. Furthermore, hip replacement surgery has significant associated risks. We offer a conservative approach to hip replacement using radiofrequency lesioning. METHODS: This is a case series of 4 patients who had anterior and or medial hip pain who underwent percutaneous radiofrequency lesioning of the sensory branches of the obturator and femoral nerves. All of the patients had significant co-morbidities and the risks out weighed the benefits of surgery. All the patients had diagnostic blocks with local anesthetic to the sensory articular branches of the obturator and femoral nerves and showed temporary benefit. Continuous radiofrequency lesioning was performed from 60 degrees C to 80 degrees C for 90 seconds. The outcome measures were improvement in visual analogue scale (VAS), improvement in function and the decreased use of pain medications. RESULTS: All four patients had reduction in pain, while 3 of 4 patients had improved functioning. Two of the four patients had decreased use of their pain medication. One of the four patients reported numbness at the hip and there were no other side effects. CONCLUSION: Percutaneous radiofrequency lesioning of the sensory branches of the obturator and femoral nerves appears to be a safe alternative to hip replacement, especially in those patients where surgery is not an option. Further studies are needed to confirm our results.

AI evidence extraction

At a glance
Study type
Case report
Effect direction
benefit
Population
Patients with chronic anterior and/or medial hip pain who were not good surgical candidates (significant co-morbidities)
Sample size
4
Exposure
medical radiofrequency lesioning (percutaneous radiofrequency lesioning of sensory nerve branches) · 90 seconds (continuous radiofrequency lesioning)
Evidence strength
Very low
Confidence: 74% · Peer-reviewed: yes

Main findings

In a case series of 4 patients, all reported reduced pain after percutaneous radiofrequency lesioning of sensory branches of the obturator and femoral nerves. Function improved in 3/4 patients and pain medication use decreased in 2/4; one patient reported hip numbness and no other side effects were reported.

Outcomes measured

  • Pain reduction (VAS)
  • Function improvement
  • Decreased use of pain medications
  • Adverse effects (numbness/side effects)

Limitations

  • Case series with very small sample size (n=4)
  • No control/comparator group
  • Short/unspecified follow-up duration in abstract
  • Outcomes largely patient-reported and not fully quantified beyond counts
View raw extracted JSON
{
  "study_type": "case_report",
  "exposure": {
    "band": null,
    "source": "medical radiofrequency lesioning (percutaneous radiofrequency lesioning of sensory nerve branches)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": "90 seconds (continuous radiofrequency lesioning)"
  },
  "population": "Patients with chronic anterior and/or medial hip pain who were not good surgical candidates (significant co-morbidities)",
  "sample_size": 4,
  "outcomes": [
    "Pain reduction (VAS)",
    "Function improvement",
    "Decreased use of pain medications",
    "Adverse effects (numbness/side effects)"
  ],
  "main_findings": "In a case series of 4 patients, all reported reduced pain after percutaneous radiofrequency lesioning of sensory branches of the obturator and femoral nerves. Function improved in 3/4 patients and pain medication use decreased in 2/4; one patient reported hip numbness and no other side effects were reported.",
  "effect_direction": "benefit",
  "limitations": [
    "Case series with very small sample size (n=4)",
    "No control/comparator group",
    "Short/unspecified follow-up duration in abstract",
    "Outcomes largely patient-reported and not fully quantified beyond counts"
  ],
  "evidence_strength": "very_low",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "hip pain",
    "radiofrequency lesioning",
    "obturator nerve",
    "femoral nerve",
    "pain management",
    "case series",
    "visual analogue scale"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.