  "id": 3693,
  "url": "https://nnemf.org/research/3693-laparoscopic-radiofrequency-assisted-liver-resection",
  "title": "Laparoscopic radiofrequency-assisted liver resection.",
  "authors": [
    "J C Weber",
    "G Navarra",
    "N A Habib",
    "P Bachellier",
    "D Jaeck"
  ],
  "journal": "Surgical endoscopy",
  "year": "2003",
  "doi": "10.1007/s00464-002-4263-9",
  "pmid": "15768457",
  "abstract": "Laparoscopic liver resection has not yet gained wide acceptance among hepatic surgeons, mainly because of the difficulties encountered in dealing with possible intraoperative bleeding. A new technique of laparoscopic liver resection is presented. A 43-year-old man with a large and symptomatic hemangioma underwent a laparoscopic radiofrequency energy-assisted liver resection. After induction of pneumoperitoneum, four trocars were introduced and intraoperative ultrasonography and coagulative desiccation were performed along a plane of tissue 1 cm away from the edge of the lesion using the Cool-Tip radiofrequency probe and a 500-kHz, radiofrequency generator. The necrosed band of parenchyma then was divided and the specimen removed. The operative time was 300 min with a resection time of 240 min. The intraoperative blood loss was 75 ml. The postoperative course was uneventful and the patient was discharged on postoperative day 6. Laparoscopic radiofrequency-assisted liver resection is feasible, and with greater experience may contribute to the wider use of mini-invasive video-assisted liver surgery.",
  "effect": "unclear",
  "evidence": "very_low",
  "extraction": {
    "studyType": "case_report",
    "studyTypeLabel": "Case report",
    "effectDirection": "unclear",
    "evidenceLabel": "Very low",
    "population": "43-year-old man with a large symptomatic hemangioma",
    "sampleSize": "1",
    "exposure": "RF medical device (radiofrequency generator/probe) · 0.5 MHz",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "A laparoscopic radiofrequency energy-assisted liver resection was performed using a 500-kHz radiofrequency generator and Cool-Tip probe. Operative time was 300 minutes (resection time 240 minutes), blood loss was 75 ml, postoperative course was uneventful, and discharge occurred on postoperative day 6.",
    "outcomes": [
      "Feasibility of laparoscopic radiofrequency-assisted liver resection",
      "Operative time",
      "Resection time",
      "Intraoperative blood loss",
      "Postoperative course",
      "Length of hospital stay"
    ],
    "limitations": [
      "Single-patient case report",
      "No comparator/control group",
      "No quantitative assessment of EMF exposure beyond device frequency"
    ],
    "keywords": [
      "laparoscopic liver resection",
      "radiofrequency-assisted resection",
      "Cool-Tip probe",
      "500-kHz generator",
      "hemangioma",
      "blood loss",
      "feasibility"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"case_report\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"medical device (radiofrequency generator/probe)\",\n    \"frequency_mhz\": 0.5,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": \"43-year-old man with a large symptomatic hemangioma\",\n  \"sample_size\": 1,\n  \"outcomes\": [\n    \"Feasibility of laparoscopic radiofrequency-assisted liver resection\",\n    \"Operative time\",\n    \"Resection time\",\n    \"Intraoperative blood loss\",\n    \"Postoperative course\",\n    \"Length of hospital stay\"\n  ],\n  \"main_findings\": \"A laparoscopic radiofrequency energy-assisted liver resection was performed using a 500-kHz radiofrequency generator and Cool-Tip probe. Operative time was 300 minutes (resection time 240 minutes), blood loss was 75 ml, postoperative course was uneventful, and discharge occurred on postoperative day 6.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"Single-patient case report\",\n    \"No comparator/control group\",\n    \"No quantitative assessment of EMF exposure beyond device frequency\"\n  ],\n  \"evidence_strength\": \"very_low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"laparoscopic liver resection\",\n    \"radiofrequency-assisted resection\",\n    \"Cool-Tip probe\",\n    \"500-kHz generator\",\n    \"hemangioma\",\n    \"blood loss\",\n    \"feasibility\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/15768457/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3693",
  "updated": "2026-02-13 07:34:13"
}