  "title": "[Effect of handportable mobiletelephone microwave radiation on rat central neuron apoptosis].",
  "authors": [
    "Wei-guo Liu",
    "Xiao-feng Yang",
    "Yong-jian Zhu",
    "Hong Shen",
    "Xiu-yi Jiang",
    "Shi-ting Lu"
  ],
  "journal": "Zhonghua lao dong wei sheng zhi ye bing za zhi = Zhonghua laodong weisheng zhiyebing zazhi = Chinese journal of industrial hygiene and occupational diseases",
  "year": "2003",
  "doi": null,
  "pmid": "14761573",
  "abstract": "OBJECTIVE: To investigate the effect of handportable mobiletelephone microwave radiation on rat central nervous system by setting up rat model. METHODS: 80 healthy male SD rats (weighed about 200 g) were divided into 4 groups at random: control, radiation, decranium, decranium + radiation. TUNEL method was adopted used to detect the apoptosis of neurons after irradiation, then immunohistochemistry was used to detect Bcl-2, Bax expression in all brain tissue. RESULTS: TUNEL positive rate, Bax and Bcl-2 positive cell numbers could be found in decranium + radiation group [(26.45 +/- 9.27)%, (23.5 +/- 3.58), (11.1 +/- 2.55) respectively]. There were significant differences among control [(9.59 +/- 2.55)%, 14.2 +/- 2.46, 7.0 +/- 1.14 respectively], decranium group [(9.52 +/- 1.93)%, 15.5 +/- 1.77, 7.4 +/- 1.76], radiation group [(10.04 +/- 3.62)%, 15.9 +/- 2.02, 7.2 +/- 1.07] (P < 0.01). But the difference was not found in the ratio of Bax to Bcl-2. CONCLUSION: Microwave radiation did not affect the intact rat, but did promote the occurrence of neuron apoptosis in cranial defect rat. Bax, Bcl-2 gene participated in regulation of apoptosis. The intact cranium may be an important factor to protect the neurons against handportable mobiletelephone microwave radiation to some extent.",
  "effect": "mixed",
  "evidence": "low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "mixed",
    "evidenceLabel": "Low",
    "population": "Male SD rats (~200 g)",
    "sampleSize": "80",
    "exposure": "microwave 100–3000 MHz",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "In intact rats, the radiation group did not differ significantly from control on TUNEL positivity or Bax/Bcl-2-related measures. In rats with cranial defect (decranium + radiation), TUNEL positive rate and Bax and Bcl-2 positive cell numbers were higher than in control, decranium-only, and radiation-only groups (P<0.01), while the Bax/Bcl-2 ratio did not differ.",
    "outcomes": [
      "Neuron apoptosis (TUNEL positive rate)",
      "Bax expression (immunohistochemistry)",
      "Bcl-2 expression (immunohistochemistry)",
      "Bax/Bcl-2 ratio"
    ],
    "limitations": [
      "No exposure parameters reported (e.g.",
      "frequency",
      "SAR",
      "duration)",
      "Animal model with cranial defect may limit generalizability to intact organisms",
      "Outcome assessment limited to TUNEL and immunohistochemistry markers reported in abstract"
    ],
    "keywords": [
      "mobile phone",
      "microwave radiation",
      "rat",
      "central nervous system",
      "neuron apoptosis",
      "TUNEL",
      "Bax",
      "Bcl-2",
      "cranial defect"
    ],
    "hubs": [
      {
        "slug": "cell-phones",
        "weight": "0.7",
        "reason": "Exposure source is handportable mobile telephone microwave radiation."
      }
    ],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"microwave\",\n    \"source\": \"handportable mobiletelephone\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": \"Male SD rats (~200 g)\",\n  \"sample_size\": 80,\n  \"outcomes\": [\n    \"Neuron apoptosis (TUNEL positive rate)\",\n    \"Bax expression (immunohistochemistry)\",\n    \"Bcl-2 expression (immunohistochemistry)\",\n    \"Bax/Bcl-2 ratio\"\n  ],\n  \"main_findings\": \"In intact rats, the radiation group did not differ significantly from control on TUNEL positivity or Bax/Bcl-2-related measures. In rats with cranial defect (decranium + radiation), TUNEL positive rate and Bax and Bcl-2 positive cell numbers were higher than in control, decranium-only, and radiation-only groups (P<0.01), while the Bax/Bcl-2 ratio did not differ.\",\n  \"effect_direction\": \"mixed\",\n  \"limitations\": [\n    \"No exposure parameters reported (e.g., frequency, SAR, duration)\",\n    \"Animal model with cranial defect may limit generalizability to intact organisms\",\n    \"Outcome assessment limited to TUNEL and immunohistochemistry markers reported in abstract\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"mobile phone\",\n    \"microwave radiation\",\n    \"rat\",\n    \"central nervous system\",\n    \"neuron apoptosis\",\n    \"TUNEL\",\n    \"Bax\",\n    \"Bcl-2\",\n    \"cranial defect\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"mobile-phones\",\n      \"weight\": 0.9,\n      \"reason\": \"Exposure source is handportable mobile telephone microwave radiation.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/14761573/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3725",