  "abstract": "OBJECTIVE: To study the effect of extremely low frequency magnetic fields on intracellular calcium concentration ([Ca(2+)]i). METHODS: Fura-2 loaded HepG2 cells were exposed to 1.55 mT (average value), 16 Hz pulsed magnetic fields for 60 min and to 300 mT, 2 Hz rotating magnetic fields for 5 min, and then [Ca(2+)]i was measured by fluorescence spectrophotometer. [Ca(2+)]i of HepG2 cells was also measured when they were exposed to 0.9 mT [root mean square (rms)], 16 Hz sinusoidal magnetic fields in real time. RESULTS: The R values (F(340) nm/F(380) nm) of the control and the exposed group were 2.4519 +/- 0.2378 and 2.5266 +/- 0.2915 respectively after HepG2 cells were exposed to 1.55 mT, 16 Hz magnetic fields, 1.365 0 +/- 0.0626 and 1.3602 +/- 0.0771 respectively to 300 mT, 2 Hz rotating magnetic fields. The ratios of the trendline slope [r((501 - 1,000)) / r((0 - 500))] from the data of R values were 1.1213 +/- 0.4559 and 1.0727 +/- 0.1971 respectively (P > 0.05), and the ratios of the intercept [b((501 - 1,000)) / b((0 - 500))] from the trendline were 0.9912 +/- 0.0098 and 0.9979 +/- 0.0060 (P > 0.05) when HepG2 cells were exposed to the 0.9 mT, 16 Hz sinusoidal magnetic fields. CONCLUSION: The effect of extremely low frequency magnetic fields on [Ca(2+)]i of HepG2 cells under the experimental condition has not been found.",
  "effect": "no_effect",
  "evidence": "low",
  "extraction": {
    "studyType": "in_vitro",
    "studyTypeLabel": "In vitro study",
    "effectDirection": "no_effect",
    "evidenceLabel": "Low",
    "population": "HepG2 cells",
    "sampleSize": "—",
    "exposure": "ELF · 60 min (1.55 mT, 16 Hz pulsed); 5 min (300 mT, 2 Hz rotating); real-time measurement during 0.9 mT, 16 Hz sinusoidal exposure",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "No statistically significant differences in Fura-2 fluorescence ratio measures were observed between control and exposed HepG2 cells under 1.55 mT 16 Hz pulsed exposure, 300 mT 2 Hz rotating exposure, or during real-time 0.9 mT 16 Hz sinusoidal exposure (P > 0.05). The authors conclude no effect on intracellular free calcium under the experimental conditions.",
    "outcomes": [
      "intracellular free calcium concentration ([Ca2+]i)",
      "Fura-2 fluorescence ratio R (F340/F380)"
    ],
    "limitations": [
      "Sample size not reported in abstract",
      "Only one cell line (HepG2) studied",
      "Limited exposure conditions/durations reported (specific field types and short durations)"
    ],
    "keywords": [
      "extremely low frequency",
      "magnetic fields",
      "ELF",
      "HepG2",
      "intracellular calcium",
      "Fura-2",
      "fluorescence spectrophotometer",
      "pulsed magnetic field",
      "rotating magnetic field",
      "sinusoidal magnetic field"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Published in an industrial hygiene/occupational diseases journal and studies ELF magnetic field exposure effects (though in vitro)."
      }
    ],
    "raw": "{\n  \"study_type\": \"in_vitro\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": null,\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"60 min (1.55 mT, 16 Hz pulsed); 5 min (300 mT, 2 Hz rotating); real-time measurement during 0.9 mT, 16 Hz sinusoidal exposure\"\n  },\n  \"population\": \"HepG2 cells\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"intracellular free calcium concentration ([Ca2+]i)\",\n    \"Fura-2 fluorescence ratio R (F340/F380)\"\n  ],\n  \"main_findings\": \"No statistically significant differences in Fura-2 fluorescence ratio measures were observed between control and exposed HepG2 cells under 1.55 mT 16 Hz pulsed exposure, 300 mT 2 Hz rotating exposure, or during real-time 0.9 mT 16 Hz sinusoidal exposure (P > 0.05). The authors conclude no effect on intracellular free calcium under the experimental conditions.\",\n  \"effect_direction\": \"no_effect\",\n  \"limitations\": [\n    \"Sample size not reported in abstract\",\n    \"Only one cell line (HepG2) studied\",\n    \"Limited exposure conditions/durations reported (specific field types and short durations)\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"extremely low frequency\",\n    \"magnetic fields\",\n    \"ELF\",\n    \"HepG2\",\n    \"intracellular calcium\",\n    \"Fura-2\",\n    \"fluorescence spectrophotometer\",\n    \"pulsed magnetic field\",\n    \"rotating magnetic field\",\n    \"sinusoidal magnetic field\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.35,\n      \"reason\": \"Published in an industrial hygiene/occupational diseases journal and studies ELF magnetic field exposure effects (though in vitro).\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/14761392/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3731",
  "updated": "2026-02-13 07:34:46"
}