  "abstract": "OBJECTIVE: To study the effects of low frequency pulsed magnetic field on the proliferation and differentiation of HepG2 cells. METHODS: 3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium (MTS) colorimetry method and ELISA assay of alpha-fetoprotein (AFP) were used to determine the cell proliferation and differentiation after the cells were exposed to pulsed magnetic fields with different frequency but the same field intensity. RESULTS: There were no significant differences in cell proliferation between sham and treated groups exposed to the field of 80 Hz, 1.55 mT for 1, 4, 8, 12, 24 h (P > 0.05). There were also no significant differences in cell proliferation and AFP secretion between sham and treated groups exposed to 16 Hz, 1.55 mT pulsed magnetic fields for 1, 4, 8, 24 h (P > 0.05). CONCLUSION: There were no \"window effects\" found in HepG2 cells proliferation or AFP secretion at 16 Hz and 80 Hz pulsed magnetic fields.",
  "effect": "no_effect",
  "evidence": "low",
  "extraction": {
    "studyType": "in_vitro",
    "studyTypeLabel": "In vitro study",
    "effectDirection": "no_effect",
    "evidenceLabel": "Low",
    "population": "HepG2 cells",
    "sampleSize": "—",
    "exposure": "ELF pulsed magnetic field · 1, 4, 8, 12, 24 h (80 Hz); 1, 4, 8, 24 h (16 Hz)",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "No significant differences in cell proliferation were observed between sham and exposed groups at 80 Hz, 1.55 mT for 1–24 h. No significant differences in cell proliferation or AFP secretion were observed between sham and exposed groups at 16 Hz, 1.55 mT for 1–24 h; no “window effects” were found at 16 Hz or 80 Hz.",
    "outcomes": [
      "Cell proliferation (MTS assay)",
      "Alpha-fetoprotein (AFP) secretion (ELISA)",
      "Cell differentiation (via AFP secretion)"
    ],
    "limitations": [
      "In vitro study (HepG2 cell line)",
      "generalizability to humans not addressed",
      "Sample size not reported in abstract",
      "Only two frequencies tested at a single field intensity (1.55 mT)",
      "Limited endpoints reported (proliferation and AFP secretion)"
    ],
    "keywords": [
      "ELF",
      "pulsed magnetic field",
      "HepG2",
      "cell proliferation",
      "alpha-fetoprotein",
      "AFP",
      "MTS",
      "ELISA",
      "window effect",
      "16 Hz",
      "80 Hz",
      "1.55 mT"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Published in an industrial hygiene/occupational diseases journal and studies low-frequency magnetic field exposure."
      }
    ],
    "raw": "{\n  \"study_type\": \"in_vitro\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": \"pulsed magnetic field\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"1, 4, 8, 12, 24 h (80 Hz); 1, 4, 8, 24 h (16 Hz)\"\n  },\n  \"population\": \"HepG2 cells\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Cell proliferation (MTS assay)\",\n    \"Alpha-fetoprotein (AFP) secretion (ELISA)\",\n    \"Cell differentiation (via AFP secretion)\"\n  ],\n  \"main_findings\": \"No significant differences in cell proliferation were observed between sham and exposed groups at 80 Hz, 1.55 mT for 1–24 h. No significant differences in cell proliferation or AFP secretion were observed between sham and exposed groups at 16 Hz, 1.55 mT for 1–24 h; no “window effects” were found at 16 Hz or 80 Hz.\",\n  \"effect_direction\": \"no_effect\",\n  \"limitations\": [\n    \"In vitro study (HepG2 cell line); generalizability to humans not addressed\",\n    \"Sample size not reported in abstract\",\n    \"Only two frequencies tested at a single field intensity (1.55 mT)\",\n    \"Limited endpoints reported (proliferation and AFP secretion)\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"ELF\",\n    \"pulsed magnetic field\",\n    \"HepG2\",\n    \"cell proliferation\",\n    \"alpha-fetoprotein\",\n    \"AFP\",\n    \"MTS\",\n    \"ELISA\",\n    \"window effect\",\n    \"16 Hz\",\n    \"80 Hz\",\n    \"1.55 mT\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.35,\n      \"reason\": \"Published in an industrial hygiene/occupational diseases journal and studies low-frequency magnetic field exposure.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/14761390/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3732",
  "updated": "2026-02-13 07:34:46"
}