{
  "id": 3746,
  "url": "https://nnemf.org/research/3746-a-radiofrequency-modified-maze-and-valve-procedure-through",
  "title": "A radiofrequency modified maze and valve procedure through a port-access approach.",
  "authors": [
    "Mustafa Güden",
    "Belhhan Akpinar",
    "Ertan Sagbas",
    "Ilhan Sanisoglu",
    "Mehmet U Ergenoglu",
    "Ugur Ozbek"
  ],
  "journal": "The heart surgery forum",
  "year": "2003",
  "doi": null,
  "pmid": "14721796",
  "abstract": "BACKGROUND: The aim of the study was to assess the feasibility and effectiveness of the irrigated radiofrequency modified maze procedure through a port-access approach during mitral valve surgery. METHODS: Forty-three patients with atrial fibrillation (AF) and mitral valve disease underwent a combined procedure through a port-access approach. The indication was a history of continuous AF for more than 6 months in patients eligible for minimally invasive mitral valve surgery. RESULTS: The incidence of early mortality was 1 patient (2.3%), and that of freedom from AF was 100% at the end of the operation (70% of patients with normal sinus rhythm, 30% with a pacemaker). One patient (2.3%) required permanent pacemaker implantation after surgery. One patient (2.3%) required reoperation for bleeding. There were no reoperations for failed valve repairs. The incidences of freedom from AF were 87% and 92% at 6 and 12 months, respectively. At 12 months, functional capacity had improved significantly (P < .05). There were no procedure-related complications. No thromboembolic events were detected during follow-up. CONCLUSION: The port-access approach provided a good access for both valve surgery and the radiofrequency maze procedure. The combination of direct and videoscopic vision allowed an adequate view and led to a safe and efficient combined procedure. Short- and intermediate-term follow-up results were favorable.",
  "effect": "benefit",
  "evidence": "low",
  "extraction": {
    "studyType": "other",
    "studyTypeLabel": "Other",
    "effectDirection": "benefit",
    "evidenceLabel": "Low",
    "population": "Patients with atrial fibrillation and mitral valve disease undergoing minimally invasive mitral valve surgery",
    "sampleSize": "43",
    "exposure": "RF",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "In 43 patients, early mortality was 2.3%. Freedom from AF was reported as 100% at the end of the operation and 87% and 92% at 6 and 12 months, respectively; functional capacity improved significantly at 12 months (P<.05). One patient required permanent pacemaker implantation and one required reoperation for bleeding; no procedure-related complications or thromboembolic events were detected during follow-up.",
    "outcomes": [
      "Feasibility of port-access approach for irrigated radiofrequency modified maze during mitral valve surgery",
      "Early mortality",
      "Freedom from atrial fibrillation (end of operation",
      "6 and 12 months)",
      "Need for permanent pacemaker implantation",
      "Reoperation for bleeding",
      "Reoperation for failed valve repair",
      "Functional capacity at 12 months",
      "Procedure-related complications",
      "Thromboembolic events during follow-up"
    ],
    "limitations": [
      "No control/comparator group described in the abstract",
      "Follow-up limited to short/intermediate term (reported to 12 months)",
      "Frequency/dose parameters of radiofrequency energy not reported in the abstract"
    ],
    "keywords": [
      "radiofrequency",
      "modified maze procedure",
      "port-access",
      "minimally invasive",
      "mitral valve surgery",
      "atrial fibrillation",
      "pacemaker",
      "follow-up"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"other\",\n  \"exposure\": {\n    \"band\": null,\n    \"source\": \"medical radiofrequency ablation (surgical maze procedure)\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": \"Patients with atrial fibrillation and mitral valve disease undergoing minimally invasive mitral valve surgery\",\n  \"sample_size\": 43,\n  \"outcomes\": [\n    \"Feasibility of port-access approach for irrigated radiofrequency modified maze during mitral valve surgery\",\n    \"Early mortality\",\n    \"Freedom from atrial fibrillation (end of operation; 6 and 12 months)\",\n    \"Need for permanent pacemaker implantation\",\n    \"Reoperation for bleeding\",\n    \"Reoperation for failed valve repair\",\n    \"Functional capacity at 12 months\",\n    \"Procedure-related complications\",\n    \"Thromboembolic events during follow-up\"\n  ],\n  \"main_findings\": \"In 43 patients, early mortality was 2.3%. Freedom from AF was reported as 100% at the end of the operation and 87% and 92% at 6 and 12 months, respectively; functional capacity improved significantly at 12 months (P<.05). One patient required permanent pacemaker implantation and one required reoperation for bleeding; no procedure-related complications or thromboembolic events were detected during follow-up.\",\n  \"effect_direction\": \"benefit\",\n  \"limitations\": [\n    \"No control/comparator group described in the abstract\",\n    \"Follow-up limited to short/intermediate term (reported to 12 months)\",\n    \"Frequency/dose parameters of radiofrequency energy not reported in the abstract\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"radiofrequency\",\n    \"modified maze procedure\",\n    \"port-access\",\n    \"minimally invasive\",\n    \"mitral valve surgery\",\n    \"atrial fibrillation\",\n    \"pacemaker\",\n    \"follow-up\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/14721796/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3746",
  "updated": "2026-02-13 07:34:56"
}