  "id": 3812,
  "url": "https://nnemf.org/research/3812-constant-scaled-energy-spectroscopy-of-rydberg-atoms-in",
  "title": "[Constant scaled-energy spectroscopy of Rydberg atoms in a static electric field].",
  "authors": [
    "Jun-wen Cao",
    "Xiao-jun Liu",
    "Zhi Zhao",
    "Ming-sheng Zhan"
  ],
  "journal": "Guang pu xue yu guang pu fen xi = Guang pu",
  "year": "2002",
  "doi": null,
  "pmid": "12940013",
  "abstract": "In the past years, scaled energy spectroscopy is under active investigation because this method can simplify the analysis of atomic spectra in the external field based on classic mechanics. A fully computer-controlled experimental system to study the constant scaled-energy spectroscopy was established and described in this paper. The excitation energy E and the strength of the external electric field F were controlled synchronously to keep the scaled-energy epsilon = E/square root of F constant. With this system, constant scaled-energy spectra of Strontium Rydberg atoms at epsilon = -3.0 in a static electric field were successfully recorded for the first time, and the recurrence spectra were obtained by a Fourier transform.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "static electric field",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "A fully computer-controlled experimental system was established to study constant scaled-energy spectroscopy by synchronously controlling excitation energy and static electric field strength to keep scaled-energy constant. Using this system, constant scaled-energy spectra of Strontium Rydberg atoms at epsilon = -3.0 in a static electric field were recorded and recurrence spectra were obtained via Fourier transform.",
    "outcomes": [
      "constant scaled-energy spectra of Strontium Rydberg atoms",
      "recurrence spectra (Fourier transform)"
    ],
    "limitations": [
      "No biological/health outcomes described",
      "No quantitative field strength values reported in the abstract",
      "Sample size and experimental replication not reported"
    ],
    "keywords": [
      "scaled energy spectroscopy",
      "Rydberg atoms",
      "static electric field",
      "Strontium",
      "Fourier transform",
      "recurrence spectra"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": null,\n    \"source\": \"static electric field\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"constant scaled-energy spectra of Strontium Rydberg atoms\",\n    \"recurrence spectra (Fourier transform)\"\n  ],\n  \"main_findings\": \"A fully computer-controlled experimental system was established to study constant scaled-energy spectroscopy by synchronously controlling excitation energy and static electric field strength to keep scaled-energy constant. Using this system, constant scaled-energy spectra of Strontium Rydberg atoms at epsilon = -3.0 in a static electric field were recorded and recurrence spectra were obtained via Fourier transform.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No biological/health outcomes described\",\n    \"No quantitative field strength values reported in the abstract\",\n    \"Sample size and experimental replication not reported\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"scaled energy spectroscopy\",\n    \"Rydberg atoms\",\n    \"static electric field\",\n    \"Strontium\",\n    \"Fourier transform\",\n    \"recurrence spectra\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/12940013/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3812",
  "updated": "2026-02-13 07:37:55"
}