{
  "id": 3846,
  "url": "https://nnemf.org/research/3846-design-of-mc-iii-low-frequency-pulsed-strong",
  "title": "[Design of MC-III low frequency pulsed strong magnetic fields generator].",
  "authors": [
    "Jun Wen",
    "Lisheng Zhong",
    "Hengkun Xie",
    "Xuemin Qu",
    "Hongbo Ju",
    "Jiqing Yang",
    "Sigang Wang"
  ],
  "journal": "Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi",
  "year": "2002",
  "doi": null,
  "pmid": "12561349",
  "abstract": "In this paper, We designed and accomplished a low frequency pulsed strong magnetic fields generator, which provides a pulsed magnetic field with the intensity range from 0.1-2.5 T and the adjusted time interval of pulse. This device is easy to operate and performs reliably. It can work steady for a long time and has been successful used in the experiments of biological effects of electromagnetics.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "ELF pulsed strong magnetic field generator · adjusted time interval of pulse",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "The authors designed and built a low-frequency pulsed strong magnetic field generator producing pulsed magnetic fields with intensity 0.1–2.5 T and adjustable pulse intervals. The device is described as easy to operate, reliable, and capable of steady long-term operation, and it has been used in experiments on biological effects of electromagnetics.",
    "outcomes": [
      "Device design/performance (generation of low-frequency pulsed strong magnetic fields)",
      "Magnetic field intensity range (0.1–2.5 T)",
      "Operational reliability/long-term steady operation",
      "Use in experiments on biological effects of electromagnetics (mentioned)"
    ],
    "limitations": [
      "No biological experiment methods or results are provided in the abstract.",
      "Frequency and waveform parameters beyond 'low frequency' and 'pulsed' are not specified.",
      "No quantitative performance metrics (e.g.",
      "field uniformity",
      "rise time) are reported in the abstract."
    ],
    "keywords": [
      "low frequency",
      "pulsed magnetic field",
      "strong magnetic field generator",
      "0.1-2.5 T",
      "device design",
      "biomedical engineering"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Engineering of a strong magnetic field generator could be relevant to laboratory/occupational exposure contexts, though no specific occupational setting is described."
      }
    ],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": \"pulsed strong magnetic field generator\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"adjusted time interval of pulse\"\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Device design/performance (generation of low-frequency pulsed strong magnetic fields)\",\n    \"Magnetic field intensity range (0.1–2.5 T)\",\n    \"Operational reliability/long-term steady operation\",\n    \"Use in experiments on biological effects of electromagnetics (mentioned)\"\n  ],\n  \"main_findings\": \"The authors designed and built a low-frequency pulsed strong magnetic field generator producing pulsed magnetic fields with intensity 0.1–2.5 T and adjustable pulse intervals. The device is described as easy to operate, reliable, and capable of steady long-term operation, and it has been used in experiments on biological effects of electromagnetics.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No biological experiment methods or results are provided in the abstract.\",\n    \"Frequency and waveform parameters beyond 'low frequency' and 'pulsed' are not specified.\",\n    \"No quantitative performance metrics (e.g., field uniformity, rise time) are reported in the abstract.\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"low frequency\",\n    \"pulsed magnetic field\",\n    \"strong magnetic field generator\",\n    \"0.1-2.5 T\",\n    \"device design\",\n    \"biomedical engineering\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.2,\n      \"reason\": \"Engineering of a strong magnetic field generator could be relevant to laboratory/occupational exposure contexts, though no specific occupational setting is described.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/12561349/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3846",
  "updated": "2026-02-13 07:38:18"
}