Share

Effect of electromagnetic fields and early postoperative 5-fluorouracil on the healing of colonic anastomoses.

Ali Nayci, Murat Cakmak, Nurten Renda, Selim Aksoyek, Selcuk Yucesan

PAPERpubmedInternational journal of colorectal disease2003Animal studyEffect: benefitEvidence: Low

Abstract

BACKGROUND AND AIMS: Studies have indicated a deleterious effect of perioperative 5-fluorouracil (5-FU) administration on the healing of intestinal anastomoses. This study examined the effect of early postoperative 5-FU on the healing of colonic anastomoses and investigated the effect of electromagnetic fields (EMF) on colonic anastomotic repair under normal physiological conditions and in the presence of 5-FU therapy in a rat model. MATERIALS AND METHODS: Forty male Wistar rats were randomly assigned into four groups and underwent a standardized left colonic resection and anastomoses. The animals then served as control or received intraperitoneal 5-FU (20 mg/kg per day, 5 days), EMF stimulation (10.76 mT, 50 Hz; 2-h on/10-h off cycles, 7 days) or both, starting on the day of surgery. After 7 days anastomotic healing was assessed by measurement of hydroxyproline content and breaking strength. RESULTS: Hydroxyproline content increased in EMF exposed group (1.53+/-0.11 to 1.92+/-0.11 microg/mg) and in EMF + 5-FU group (1.53+/-0.11 to 1.89+/-0.12 microg/mg). Breaking strength also increased in the EMF group (0.23+/-0.02 to 0.27+/-0.01 MPa) and in the EMF + 5-FU group (0.23+/-0.02 to 0.28+/-0.01 MPa. No differences were found in hydroxyproline content or breaking strength between the 5-FU group and controls. CONCLUSION: Early postoperative 5-FU administration did not impair the healing of colonic anastomoses in rats. Additionally, EMF stimulation provided a significant gain in colonic anastomotic strength, in rat intestines in control animals and in animals exposed to 5-FU.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
benefit
Population
Male Wistar rats with standardized left colonic resection and anastomosis
Sample size
40
Exposure
ELF other · 2-h on/10-h off cycles for 7 days (starting day of surgery)
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

In rats, EMF stimulation (10.76 mT, 50 Hz) increased hydroxyproline content and anastomotic breaking strength compared with baseline/control values. No differences in hydroxyproline content or breaking strength were found between the 5-FU-only group and controls. EMF plus 5-FU also showed increased hydroxyproline and breaking strength.

Outcomes measured

  • Anastomotic healing (hydroxyproline content)
  • Anastomotic breaking strength

Limitations

  • Animal (rat) model
  • may not generalize to humans
  • Short follow-up (7 days)
  • Exposure source/device not described beyond field strength and frequency
  • Outcomes limited to hydroxyproline content and breaking strength
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "ELF",
    "source": "other",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": "2-h on/10-h off cycles for 7 days (starting day of surgery)"
  },
  "population": "Male Wistar rats with standardized left colonic resection and anastomosis",
  "sample_size": 40,
  "outcomes": [
    "Anastomotic healing (hydroxyproline content)",
    "Anastomotic breaking strength"
  ],
  "main_findings": "In rats, EMF stimulation (10.76 mT, 50 Hz) increased hydroxyproline content and anastomotic breaking strength compared with baseline/control values. No differences in hydroxyproline content or breaking strength were found between the 5-FU-only group and controls. EMF plus 5-FU also showed increased hydroxyproline and breaking strength.",
  "effect_direction": "benefit",
  "limitations": [
    "Animal (rat) model; may not generalize to humans",
    "Short follow-up (7 days)",
    "Exposure source/device not described beyond field strength and frequency",
    "Outcomes limited to hydroxyproline content and breaking strength"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "electromagnetic fields",
    "ELF",
    "50 Hz",
    "10.76 mT",
    "colonic anastomosis",
    "wound healing",
    "hydroxyproline",
    "breaking strength",
    "5-fluorouracil",
    "rat model"
  ],
  "suggested_hubs": [
    {
      "slug": "elF-emf",
      "weight": 0.8,
      "reason": "Exposure is 50 Hz, 10.76 mT electromagnetic field stimulation in an animal model."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 3847

Effect of electromagnetic fields and early postoperative 5-fluorouracil on the healing of colonic anastomoses. · Non-native EMF