  "id": 3882,
  "url": "https://nnemf.org/research/3882-real-space-formulation-of-the-quantum-mechanical-electronic",
  "title": "Real-space formulation of the quantum-mechanical electronic scattering under static n-fold axially symmetric electric and magnetic fields in a projection microscope.",
  "authors": [
    "A Mayer"
  ],
  "journal": "Ultramicroscopy",
  "year": "2001",
  "doi": "10.1016/s0304-3991(01)00138-3",
  "pmid": "11942632",
  "abstract": "A numerical technique is developed to compute electronic propagation in three-dimensional potential-energy and vector-potential distributions, as required for the quantum-mechanical modelization of scattering in static electric and magnetic fields in a projection microscope. The technique is implemented in a transfer-matrix and Green's functions general procedure to simulate field-emission and electronic projection microscopy. In particular, simulated observations of a transverse magnetic field confirms the occurrence of diffraction fringes that are oriented in the direction of the field. These diffraction fringes are mainly associated with the detection of a magnetic flux and tend to be more pronounced as this quantity increases. In the conditions of this paper, the smallest magnetic flux that was detected could be associated with a phase shift of around 2pi/8 rad.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "projection microscope (static electric and magnetic fields)",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "A numerical technique (transfer-matrix and Green's functions) was developed to simulate electron propagation/scattering in 3D static electric and magnetic field distributions for field-emission and electronic projection microscopy. Simulations of a transverse magnetic field showed diffraction fringes oriented along the field direction, mainly associated with detection of magnetic flux, becoming more pronounced with increasing flux; the smallest detected flux corresponded to an estimated phase shift of about 2π/8 rad.",
    "outcomes": [
      "electron propagation/scattering simulation in static electric and magnetic fields",
      "diffraction fringes in transverse magnetic field",
      "magnetic flux detection sensitivity (phase shift)"
    ],
    "limitations": [
      "No biological/health outcomes assessed",
      "this is a computational/engineering simulation study.",
      "Exposure metrics relevant to EMF health research (e.g.",
      "frequency",
      "SAR",
      "field strength) are not reported in the abstract."
    ],
    "keywords": [
      "static electric field",
      "static magnetic field",
      "electron scattering",
      "projection microscopy",
      "field-emission microscopy",
      "transfer-matrix",
      "Green's functions",
      "diffraction fringes",
      "magnetic flux",
      "phase shift"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": null,\n    \"source\": \"projection microscope (static electric and magnetic fields)\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"electron propagation/scattering simulation in static electric and magnetic fields\",\n    \"diffraction fringes in transverse magnetic field\",\n    \"magnetic flux detection sensitivity (phase shift)\"\n  ],\n  \"main_findings\": \"A numerical technique (transfer-matrix and Green's functions) was developed to simulate electron propagation/scattering in 3D static electric and magnetic field distributions for field-emission and electronic projection microscopy. Simulations of a transverse magnetic field showed diffraction fringes oriented along the field direction, mainly associated with detection of magnetic flux, becoming more pronounced with increasing flux; the smallest detected flux corresponded to an estimated phase shift of about 2π/8 rad.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No biological/health outcomes assessed; this is a computational/engineering simulation study.\",\n    \"Exposure metrics relevant to EMF health research (e.g., frequency, SAR, field strength) are not reported in the abstract.\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"static electric field\",\n    \"static magnetic field\",\n    \"electron scattering\",\n    \"projection microscopy\",\n    \"field-emission microscopy\",\n    \"transfer-matrix\",\n    \"Green's functions\",\n    \"diffraction fringes\",\n    \"magnetic flux\",\n    \"phase shift\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/11942632/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3882",
  "updated": "2026-02-13 07:40:11"
}