  "id": 3883,
  "url": "https://nnemf.org/research/3883-inhibition-of-proliferation-of-human-lymphoma-cells-u937",
  "title": "Inhibition of proliferation of human lymphoma cells U937 by a 50 Hz electromagnetic field.",
  "authors": [
    "B Glück",
    "V Güntzschel",
    "H Berg"
  ],
  "journal": "Cellular and molecular biology (Noisy-le-Grand, France)",
  "year": "2001",
  "doi": null,
  "pmid": "11936855",
  "abstract": "Weak pulsating electromagnetically induced fields (PEMF) by Helmholtz coils changes cell metabolism, if cells are treated with a certain range of frequency and amplitude. The influence on proliferation of human histiocytic lymphoma cells U937 has been studied applying a sinusoidal 50 Hz field with amplitudes of the flux density B = 0.3 to 4.7 mT for 4 days. No difference between experiment and control was found in the region 0.3 and 2 mT. However, stronger fields (> or =2.5 mT) inhibit cell division. Fields > or =3.5 mT treatment kill > or =80% of the cell number at the beginning (1.5 x 10(5)/ml). This effect may be an electromagnetocally induced cell death as the first step for a non-invasive application on cell proliferation process.",
  "effect": "mixed",
  "evidence": "low",
  "extraction": {
    "studyType": "in_vitro",
    "studyTypeLabel": "In vitro study",
    "effectDirection": "mixed",
    "evidenceLabel": "Low",
    "population": "—",
    "sampleSize": "—",
    "exposure": "ELF Helmholtz coils (PEMF/sinusoidal field) · 0.00005 MHz · 4 days",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "Human histiocytic lymphoma cells (U937) exposed to a 50 Hz sinusoidal magnetic field (0.3–4.7 mT) for 4 days showed no difference vs control at 0.3–2 mT. Stronger fields (≥2.5 mT) inhibited cell division, and fields ≥3.5 mT reportedly killed ≥80% of cells at the starting density (1.5×10^5/ml).",
    "outcomes": [
      "Cell proliferation/cell division",
      "Cell death/viability"
    ],
    "limitations": [
      "In vitro study (cell line)",
      "not directly generalizable to humans.",
      "Sample size/replication not reported in the abstract.",
      "Exposure characterization is limited to frequency and flux density range",
      "other parameters (e.g.",
      "waveform details beyond sinusoidal",
      "exposure uniformity) not provided in the abstract.",
      "Mechanism is speculative in the abstract (\"may be\" electromagnetically induced cell death)."
    ],
    "keywords": [
      "ELF",
      "50 Hz",
      "pulsating electromagnetic field",
      "PEMF",
      "Helmholtz coils",
      "magnetic flux density",
      "mT",
      "U937",
      "human lymphoma cells",
      "cell proliferation",
      "cell death"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"in_vitro\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": \"Helmholtz coils (PEMF/sinusoidal field)\",\n    \"frequency_mhz\": 0.00005,\n    \"sar_wkg\": null,\n    \"duration\": \"4 days\"\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Cell proliferation/cell division\",\n    \"Cell death/viability\"\n  ],\n  \"main_findings\": \"Human histiocytic lymphoma cells (U937) exposed to a 50 Hz sinusoidal magnetic field (0.3–4.7 mT) for 4 days showed no difference vs control at 0.3–2 mT. Stronger fields (≥2.5 mT) inhibited cell division, and fields ≥3.5 mT reportedly killed ≥80% of cells at the starting density (1.5×10^5/ml).\",\n  \"effect_direction\": \"mixed\",\n  \"limitations\": [\n    \"In vitro study (cell line), not directly generalizable to humans.\",\n    \"Sample size/replication not reported in the abstract.\",\n    \"Exposure characterization is limited to frequency and flux density range; other parameters (e.g., waveform details beyond sinusoidal, exposure uniformity) not provided in the abstract.\",\n    \"Mechanism is speculative in the abstract (\\\"may be\\\" electromagnetically induced cell death).\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"ELF\",\n    \"50 Hz\",\n    \"pulsating electromagnetic field\",\n    \"PEMF\",\n    \"Helmholtz coils\",\n    \"magnetic flux density\",\n    \"mT\",\n    \"U937\",\n    \"human lymphoma cells\",\n    \"cell proliferation\",\n    \"cell death\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"elf-emf\",\n      \"weight\": 0.9,\n      \"reason\": \"In vitro exposure to 50 Hz (ELF) magnetic field with mT flux densities.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/11936855/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3883",
  "updated": "2026-02-13 07:40:12"
}