  "id": 3893,
  "url": "https://nnemf.org/research/3893-evaluation-of-long-term-exposure-to-the-magnetic",
  "title": "Evaluation of long-term exposure to the magnetic field produced from power lines.",
  "authors": [
    "G Licitra",
    "N Colonna",
    "C Chiari"
  ],
  "journal": "Radiation protection dosimetry",
  "year": "2001",
  "doi": "10.1093/oxfordjournals.rpd.a006697",
  "pmid": "11878428",
  "abstract": "For some years, the Italian Regional Agencies for Environmental Protection (ARPA) have been engaged in the evaluation of long-term exposure to 50 Hz magnetic fields for receptors close to power lines. In this study, experiences and procedures are suggested in order to estimate long-term exposure levels in the case of magnetic induction produced contemporaneously by different power lines. In the simplest cases, the influence of a single line is evaluated by verifying the correlation factor between the variation of the current in each line and the measured magnetic induction. When the prevalence of a single line is not clear and systematic, much additional data (voltage, current, phases and geometrical configuration) have to be considered. The case of a school in Livomo near two lines. placed on the same supports, is described and a range of the most probable exposure values is given, corresponding to the phase change of the two current fluxes.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "receptors close to power lines; case example: a school in Livomo (Italy) near two power lines",
    "sampleSize": "—",
    "exposure": "ELF power lines · 0.05 MHz · long-term",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "The paper describes procedures to estimate long-term exposure to 50 Hz magnetic fields near power lines, including assessing correlation between line current variation and measured magnetic induction. For a school near two lines on the same supports, a range of most probable exposure values is provided corresponding to phase changes of the two current fluxes.",
    "outcomes": [
      "estimated long-term 50 Hz magnetic field exposure levels (magnetic induction) near power lines",
      "procedures for estimating exposure when multiple power lines contribute"
    ],
    "limitations": [
      "No health outcomes reported (exposure assessment only).",
      "Sample size and measurement duration/details are not provided in the abstract.",
      "Quantitative exposure values are not reported in the abstract."
    ],
    "keywords": [
      "ELF",
      "50 Hz",
      "magnetic field",
      "magnetic induction",
      "power lines",
      "long-term exposure",
      "exposure assessment",
      "Italy",
      "ARPA",
      "school"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Mentions environmental protection agencies evaluating exposure, but the described receptors include a school and nearby residents rather than workers; relevance is limited."
      }
    ],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": \"power lines\",\n    \"frequency_mhz\": 0.05,\n    \"sar_wkg\": null,\n    \"duration\": \"long-term\"\n  },\n  \"population\": \"receptors close to power lines; case example: a school in Livomo (Italy) near two power lines\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"estimated long-term 50 Hz magnetic field exposure levels (magnetic induction) near power lines\",\n    \"procedures for estimating exposure when multiple power lines contribute\"\n  ],\n  \"main_findings\": \"The paper describes procedures to estimate long-term exposure to 50 Hz magnetic fields near power lines, including assessing correlation between line current variation and measured magnetic induction. For a school near two lines on the same supports, a range of most probable exposure values is provided corresponding to phase changes of the two current fluxes.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No health outcomes reported (exposure assessment only).\",\n    \"Sample size and measurement duration/details are not provided in the abstract.\",\n    \"Quantitative exposure values are not reported in the abstract.\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"ELF\",\n    \"50 Hz\",\n    \"magnetic field\",\n    \"magnetic induction\",\n    \"power lines\",\n    \"long-term exposure\",\n    \"exposure assessment\",\n    \"Italy\",\n    \"ARPA\",\n    \"school\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.2,\n      \"reason\": \"Mentions environmental protection agencies evaluating exposure, but the described receptors include a school and nearby residents rather than workers; relevance is limited.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/11878428/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3893",
  "updated": "2026-02-13 07:40:22"
}