  "id": 3963,
  "url": "https://nnemf.org/research/3963-the-contribution-of-local-distribution-substations-and-associated",
  "title": "The contribution of local distribution substations and associated area distribution system to personal exposure to power frequency magnetic fields.",
  "authors": [
    "P Grainger",
    "A W Preece"
  ],
  "journal": "International journal of environmental health research",
  "year": "2000",
  "doi": "10.1080/09603120020011474",
  "pmid": "11260777",
  "abstract": "A number of epidemiological studies has shown a significant correlation between wire coding, magnetic fields and childhood cancer, although a more recent study has not [McBride et al. (1999) Am. J. Epidemiol. 149 (9), 831-842]. In the UK there is currently no equivalent to wire-codes and there is some uncertainty about the extent to which the UK medium-voltage electricity distribution systems contribute to personal exposure and how this compares with US overhead supply systems. Studies on four different area types were carried out to measure magnetic field intensities from typical electricity supply utility substations and cabling in the vicinity of domestic housing. Typically at distances of two metres from the substations mean magnetic field intensities were 20 nano teslas (nT) or less, increasing to 0.98 microT or less at the closest public access point. The mean magnetic field exposure level sampled around the four main test areas varied between 0.012 and 0.27 microT increasing to 0.30-0.80 microT at road junctions.",
  "effect": "unclear",
  "evidence": "low",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "unclear",
    "evidenceLabel": "Low",
    "population": "—",
    "sampleSize": "—",
    "exposure": "ELF <1 MHz",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "Measurements in four area types near domestic housing found mean magnetic field intensities typically ≤20 nT at 2 m from substations, rising to ≤0.98 µT at the closest public access point. Mean sampled exposure around the four test areas ranged from 0.012 to 0.27 µT, increasing to 0.30–0.80 µT at road junctions.",
    "outcomes": [
      "Magnetic field intensity levels (power frequency) in residential vicinity",
      "Area magnetic field exposure levels around test areas"
    ],
    "limitations": [
      "No sample size or detailed measurement protocol provided in the abstract",
      "Frequency (e.g.",
      "50 Hz) not explicitly stated in the abstract",
      "Population/personal monitoring details not described",
      "results appear to be area measurements rather than individual dosimetry"
    ],
    "keywords": [
      "power frequency",
      "ELF magnetic fields",
      "distribution substations",
      "medium-voltage distribution",
      "cabling",
      "residential exposure",
      "UK"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Focus is on utility distribution infrastructure; however measurements are described near domestic housing rather than workplaces."
      }
    ],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": \"local distribution substations and area distribution system (medium-voltage distribution; cabling near domestic housing)\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Magnetic field intensity levels (power frequency) in residential vicinity\",\n    \"Area magnetic field exposure levels around test areas\"\n  ],\n  \"main_findings\": \"Measurements in four area types near domestic housing found mean magnetic field intensities typically ≤20 nT at 2 m from substations, rising to ≤0.98 µT at the closest public access point. Mean sampled exposure around the four test areas ranged from 0.012 to 0.27 µT, increasing to 0.30–0.80 µT at road junctions.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No sample size or detailed measurement protocol provided in the abstract\",\n    \"Frequency (e.g., 50 Hz) not explicitly stated in the abstract\",\n    \"Population/personal monitoring details not described; results appear to be area measurements rather than individual dosimetry\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"power frequency\",\n    \"ELF magnetic fields\",\n    \"distribution substations\",\n    \"medium-voltage distribution\",\n    \"cabling\",\n    \"residential exposure\",\n    \"UK\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.1,\n      \"reason\": \"Focus is on utility distribution infrastructure; however measurements are described near domestic housing rather than workplaces.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/11260777/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3963",
  "updated": "2026-02-13 07:44:48"
}