{
  "id": 4025,
  "url": "https://nnemf.org/research/4025-magnetic-field-induced-alignment-of-the-directors-of",
  "title": "Magnetic field induced alignment of the directors of a smectic-A liquid crystal.",
  "authors": [
    "J W Emsley",
    "J E Long",
    "G R Luckhurst",
    "P Pedrielli"
  ],
  "journal": "Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics",
  "year": "1999",
  "doi": "10.1103/physreve.60.1831",
  "pmid": "11969970",
  "abstract": "Deuterium NMR is used to monitor the magnetic field induced alignment of the directors in the smectic A phase of 4-octyl-4(')-cyanobiphenyl. The experiments consist of first preparing the sample as a monodomain by cooling slowly from the nematic phase in the magnetic field of the NMR spectrometer. The tube containing the sample is then rotated quickly through an angle theta(+), and the subsequent field induced alignment process followed by recording deuterium spectra over a period of time. The results obtained show that the magnetic field induced alignment of the directors in a smectic-A sample is qualitatively different from that of nematic samples. Results are reported for the pure mesogen containing deuteriums at the alpha chain position, and these are compared with data obtained on the alignment process by monitoring the deuterium spectrum of a small amount of an added solute, p-xylene-d(10).",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "other",
    "studyTypeLabel": "Other",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "magnetic field of the NMR spectrometer · spectra recorded over a period of time following sample rotation",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "Deuterium NMR monitoring indicated that magnetic-field-induced alignment of directors in a smectic-A sample is qualitatively different from that in nematic samples. Results for the pure mesogen (deuterated at the alpha chain position) were compared with alignment data obtained using deuterium spectra of a small amount of added p-xylene-d(10) solute.",
    "outcomes": [
      "magnetic-field-induced alignment of directors in smectic-A liquid crystal",
      "deuterium NMR spectra changes over time during alignment process",
      "comparison of alignment behavior between smectic-A and nematic samples"
    ],
    "limitations": [
      "No magnetic field strength or NMR operating frequency reported in the abstract.",
      "No quantitative results or effect sizes described in the abstract.",
      "Not a health/biological effects study",
      "focuses on liquid-crystal director alignment behavior."
    ],
    "keywords": [
      "deuterium NMR",
      "magnetic field",
      "director alignment",
      "smectic-A",
      "nematic",
      "4-octyl-4'-cyanobiphenyl",
      "p-xylene-d10"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"other\",\n  \"exposure\": {\n    \"band\": null,\n    \"source\": \"magnetic field of the NMR spectrometer\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"spectra recorded over a period of time following sample rotation\"\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"magnetic-field-induced alignment of directors in smectic-A liquid crystal\",\n    \"deuterium NMR spectra changes over time during alignment process\",\n    \"comparison of alignment behavior between smectic-A and nematic samples\"\n  ],\n  \"main_findings\": \"Deuterium NMR monitoring indicated that magnetic-field-induced alignment of directors in a smectic-A sample is qualitatively different from that in nematic samples. Results for the pure mesogen (deuterated at the alpha chain position) were compared with alignment data obtained using deuterium spectra of a small amount of added p-xylene-d(10) solute.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No magnetic field strength or NMR operating frequency reported in the abstract.\",\n    \"No quantitative results or effect sizes described in the abstract.\",\n    \"Not a health/biological effects study; focuses on liquid-crystal director alignment behavior.\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"deuterium NMR\",\n    \"magnetic field\",\n    \"director alignment\",\n    \"smectic-A\",\n    \"nematic\",\n    \"4-octyl-4'-cyanobiphenyl\",\n    \"p-xylene-d10\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/11969970/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=4025",
  "updated": "2026-02-13 07:47:17"
}