A practically zero horizontal magnetic field in a planar undulator used in the Tristan Super Light Facility.

S Yamamoto, K Tsuchiya, T Shioya, D Amano, H Sugiyama

PAPERpubmedJournal of synchrotron radiation1998engineeringEffect: no_effectEvidence: Insufficient

Abstract

The Tristan Main Ring (MR) at KEK (High Energy Accelerator Research Organization) has been used as a third-generation synchrotron radiation ring with an undulator installed in the MR as a third-generation light source. The magnetic field irregularities of the undulator were examined precisely. Measurement of the magnetic field after synchrotron radiation experiments showed that the magnetic irregularities in both the horizontal and vertical directions are negligibly small. This result suggests that our previous estimates of emittance, made using the measured undulator spectrum, should correctly represent the properties of the electron beam in the MR.

AI evidence extraction

At a glance
Study type
engineering
Effect direction
no_effect
Population
—
Sample size
—
Exposure
planar undulator (synchrotron radiation facility)
Evidence strength
Insufficient
Confidence: 74% · Peer-reviewed: yes

Main findings

Precise measurements of the undulator magnetic field after synchrotron radiation experiments indicated that magnetic irregularities in both horizontal and vertical directions were negligibly small. The authors suggest this supports the correctness of prior emittance estimates based on the measured undulator spectrum.

Outcomes measured

  • magnetic field irregularities (horizontal and vertical)
  • undulator magnetic field measurements
  • electron beam emittance estimates (via measured undulator spectrum)
View raw extracted JSON
{
  "study_type": "engineering",
  "exposure": {
    "band": null,
    "source": "planar undulator (synchrotron radiation facility)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "magnetic field irregularities (horizontal and vertical)",
    "undulator magnetic field measurements",
    "electron beam emittance estimates (via measured undulator spectrum)"
  ],
  "main_findings": "Precise measurements of the undulator magnetic field after synchrotron radiation experiments indicated that magnetic irregularities in both horizontal and vertical directions were negligibly small. The authors suggest this supports the correctness of prior emittance estimates based on the measured undulator spectrum.",
  "effect_direction": "no_effect",
  "limitations": [],
  "evidence_strength": "insufficient",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "planar undulator",
    "synchrotron radiation",
    "magnetic field",
    "field irregularities",
    "horizontal magnetic field",
    "vertical magnetic field",
    "emittance",
    "Tristan Main Ring",
    "KEK"
  ],
  "suggested_hubs": [
    {
      "slug": "engineering-measurement",
      "weight": 0.62,
      "reason": "Engineering-focused magnetic field measurement and characterization of an undulator in a synchrotron facility."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 4046

A practically zero horizontal magnetic field in a planar undulator used in the Tristan Super Light Facility. · Non-native EMF