{
  "id": 4061,
  "url": "https://nnemf.org/research/4061-mechanical-properties-of-resin-composites-with-filler-particles",
  "title": "Mechanical properties of resin composites with filler particles aligned by an electric field.",
  "authors": [
    "C Park",
    "R E Robertson"
  ],
  "journal": "Dental materials : official publication of the Academy of Dental Materials",
  "year": "1998",
  "doi": "10.1016/s0300-5712(99)00011-1",
  "pmid": "10483399",
  "abstract": "OBJECTIVES: To explore possible enhancement of the mechanical properties of resin composites by aligning the filler particles. METHODS: The resin for the composites consisted of urethane dimethacrylate (UDMA) and 1,6-hexanediol dimethacrylate (HDDMA) mixed in the ratio of 90 to 10; the filler was silica-zirconia in two particle sizes, 1.7 microns (P50), which was mixed with the resin in the volume fractions of 29 and 48 vol%, and 0.7 micron (Z100), which was mixed with the resin in the volume fractions of 37 and 57 vol%. Particle alignment was obtained by applying a 60 Hz AC electric field across the composite before the resin was photopolymerized. The stress-strain behavior and the elastic modulus of the hardened composite were measured along the alignment axis in compression. RESULTS: The elastic moduli of the aligned composites increased by as much as 20%, and the maximum stress sustainable in compression before significant deformation occurred was elevated. An electric field strength of the order of 1 kV mm-1 was required to obtain sufficient alignment. SIGNIFICANCE: Besides conferring a structure to resin composites that is more like that of the natural tooth, particle alignment increased some of the mechanical properties and may have improved durability.",
  "effect": "benefit",
  "evidence": "low",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "benefit",
    "evidenceLabel": "Low",
    "population": "—",
    "sampleSize": "—",
    "exposure": "ELF <1 MHz",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "Silica-zirconia filler particles were aligned in resin composites using a 60 Hz AC electric field prior to photopolymerization. Aligned composites showed elastic modulus increases up to about 20% and higher maximum compressive stress before significant deformation; field strength on the order of 1 kV/mm was reported as required for sufficient alignment.",
    "outcomes": [
      "Elastic modulus",
      "Compressive stress/maximum sustainable stress before significant deformation",
      "Stress-strain behavior"
    ],
    "limitations": [
      "No sample size reported in abstract",
      "No details provided on experimental replication/variability or statistical testing in abstract",
      "Exposure duration and exact field parameters beyond frequency and approximate strength not reported in abstract"
    ],
    "keywords": [
      "resin composites",
      "dental materials",
      "filler particle alignment",
      "electric field",
      "60 Hz",
      "AC electric field",
      "elastic modulus",
      "compression"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": \"other\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Elastic modulus\",\n    \"Compressive stress/maximum sustainable stress before significant deformation\",\n    \"Stress-strain behavior\"\n  ],\n  \"main_findings\": \"Silica-zirconia filler particles were aligned in resin composites using a 60 Hz AC electric field prior to photopolymerization. Aligned composites showed elastic modulus increases up to about 20% and higher maximum compressive stress before significant deformation; field strength on the order of 1 kV/mm was reported as required for sufficient alignment.\",\n  \"effect_direction\": \"benefit\",\n  \"limitations\": [\n    \"No sample size reported in abstract\",\n    \"No details provided on experimental replication/variability or statistical testing in abstract\",\n    \"Exposure duration and exact field parameters beyond frequency and approximate strength not reported in abstract\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"resin composites\",\n    \"dental materials\",\n    \"filler particle alignment\",\n    \"electric field\",\n    \"60 Hz\",\n    \"AC electric field\",\n    \"elastic modulus\",\n    \"compression\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/10483399/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=4061",
  "updated": "2026-02-13 07:48:15"
}