  "title": "Improved resolution in the gel electrophoresis of proteins by a periodically interrupted electric field.",
  "authors": [
    "N Chen",
    "A Chrambach"
  ],
  "journal": "Journal of biochemical and biophysical methods",
  "year": "1996",
  "doi": "10.1016/s0165-022x(96)00021-8",
  "pmid": "9029260",
  "abstract": "The capability of the commercial gel electrophoresis apparatus with intermittent scanning of fluorescence (HPGE-1000, LabIntelligence) to provide time-dependent zone dispersion allows one to quantitate resolution. Using a model protein separation, that between phycoerythrin and fluorescein-labeled conalbumin, resolution was compared between separations conducted at a constant field strength of 80 V/cm and one conducted in 10-s pulses of the same field strength, interrupted periodically by 120 s in the absence of an electric field. Resolution was improved by a factor of two in the discontinuous application of the electric field compared to that obtained in its continuous application. Similarly, the intermittent application of 80 V/cm for 10 s, followed by 120-s pauses, gave rise to twice the resolution obtained from a continuous application of 7 V/cm.",
  "effect": "benefit",
  "evidence": "low",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "benefit",
    "evidenceLabel": "Low",
    "population": "—",
    "sampleSize": "—",
    "exposure": "gel electrophoresis apparatus (electric field) · 10-s pulses interrupted by 120 s without field (also compared to continuous application)",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "In a model protein separation (phycoerythrin vs fluorescein-labeled conalbumin), applying an electric field discontinuously (80 V/cm in 10-s pulses with 120-s pauses) produced about twice the resolution compared with continuous application of 80 V/cm. The same intermittent 80 V/cm protocol also yielded about twice the resolution compared with continuous application of 7 V/cm.",
    "outcomes": [
      "Protein separation resolution (zone dispersion-based quantitated resolution)"
    ],
    "limitations": [
      "No sample size or number of runs reported in the abstract",
      "Study is a methodological/engineering application in gel electrophoresis rather than a health-effects study",
      "Limited to a specific model protein separation and specific apparatus/protocol described"
    ],
    "keywords": [
      "gel electrophoresis",
      "electric field",
      "pulsed field",
      "intermittent field",
      "protein separation",
      "resolution",
      "zone dispersion",
      "fluorescence scanning"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": null,\n    \"source\": \"gel electrophoresis apparatus (electric field)\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"10-s pulses interrupted by 120 s without field (also compared to continuous application)\"\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Protein separation resolution (zone dispersion-based quantitated resolution)\"\n  ],\n  \"main_findings\": \"In a model protein separation (phycoerythrin vs fluorescein-labeled conalbumin), applying an electric field discontinuously (80 V/cm in 10-s pulses with 120-s pauses) produced about twice the resolution compared with continuous application of 80 V/cm. The same intermittent 80 V/cm protocol also yielded about twice the resolution compared with continuous application of 7 V/cm.\",\n  \"effect_direction\": \"benefit\",\n  \"limitations\": [\n    \"No sample size or number of runs reported in the abstract\",\n    \"Study is a methodological/engineering application in gel electrophoresis rather than a health-effects study\",\n    \"Limited to a specific model protein separation and specific apparatus/protocol described\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"gel electrophoresis\",\n    \"electric field\",\n    \"pulsed field\",\n    \"intermittent field\",\n    \"protein separation\",\n    \"resolution\",\n    \"zone dispersion\",\n    \"fluorescence scanning\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/9029260/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=4172",
  "updated": "2026-02-13 07:56:08"
}