  "id": 4275,
  "url": "https://nnemf.org/research/4275-orientation-of-purple-membrane-in-combined-electric-and",
  "title": "Orientation of purple membrane in combined electric and magnetic fields.",
  "authors": [
    "A Dér",
    "R Tóth-Boconádi",
    "L Keszthelyi",
    "H Kramer",
    "W Stoeckenius"
  ],
  "journal": "FEBS letters",
  "year": "1995",
  "doi": "10.1016/0014-5793(95)01365-2",
  "pmid": "8549767",
  "abstract": "The orientation of purple membrane in gels for photoelectric measurements is relatively poor, when they are prepared with the standard technique of applying a DC electric field and rapid polymerization. We have improved it by adding a high magnetic field (17.5 T) and increasing the viscosity of the membrane suspension. This process has resulted so far in a 3-fold increase of the photoelectric signals obtained. The magnetic susceptibility of purple membrane was determined.",
  "effect": "benefit",
  "evidence": "low",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "benefit",
    "evidenceLabel": "Low",
    "population": "—",
    "sampleSize": "—",
    "exposure": "combined electric and magnetic fields (DC electric field; high magnetic field)",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "Standard preparation using a DC electric field and rapid polymerization produced relatively poor orientation of purple membrane in gels. Adding a high magnetic field (17.5 T) and increasing suspension viscosity improved orientation and resulted in a 3-fold increase in photoelectric signals; magnetic susceptibility of purple membrane was determined.",
    "outcomes": [
      "orientation of purple membrane in gels",
      "photoelectric signal amplitude",
      "magnetic susceptibility of purple membrane"
    ],
    "limitations": [
      "No sample size or quantitative statistical details provided in the abstract.",
      "Exposure parameters for the DC electric field (strength",
      "duration) are not described in the abstract.",
      "Study is on purple membrane in gels (non-human",
      "non-animal biological material)",
      "limiting generalizability to health outcomes."
    ],
    "keywords": [
      "purple membrane",
      "orientation",
      "DC electric field",
      "magnetic field",
      "17.5 T",
      "viscosity",
      "photoelectric measurements",
      "magnetic susceptibility"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": null,\n    \"source\": \"combined electric and magnetic fields (DC electric field; high magnetic field)\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"orientation of purple membrane in gels\",\n    \"photoelectric signal amplitude\",\n    \"magnetic susceptibility of purple membrane\"\n  ],\n  \"main_findings\": \"Standard preparation using a DC electric field and rapid polymerization produced relatively poor orientation of purple membrane in gels. Adding a high magnetic field (17.5 T) and increasing suspension viscosity improved orientation and resulted in a 3-fold increase in photoelectric signals; magnetic susceptibility of purple membrane was determined.\",\n  \"effect_direction\": \"benefit\",\n  \"limitations\": [\n    \"No sample size or quantitative statistical details provided in the abstract.\",\n    \"Exposure parameters for the DC electric field (strength, duration) are not described in the abstract.\",\n    \"Study is on purple membrane in gels (non-human, non-animal biological material), limiting generalizability to health outcomes.\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"purple membrane\",\n    \"orientation\",\n    \"DC electric field\",\n    \"magnetic field\",\n    \"17.5 T\",\n    \"viscosity\",\n    \"photoelectric measurements\",\n    \"magnetic susceptibility\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/8549767/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=4275",
  "updated": "2026-02-13 08:05:54"
}