  "id": 4288,
  "url": "https://nnemf.org/research/4288-magnetic-field-effects-polarization-resonant-synchronous-fluorescence-spectrometry",
  "title": "Magnetic field effects-polarization-resonant synchronous fluorescence spectrometry for simultaneous analysis of polynuclear aromatic hydrocarbons in mixtures.",
  "authors": [
    "Y Zhang",
    "Y Zhu",
    "X Xue",
    "X Huang"
  ],
  "journal": "Talanta",
  "year": "1995",
  "doi": "10.1016/0039-9140(95)01629-5",
  "pmid": "18966418",
  "abstract": "The level and undulation of scattered light can be effectively suppressed by magnetic field effects-polarization-resonant synchronous fluorescence spectrometry. The established technique was used for simultaneous determination of a sample mixture containing fluorene, acenaphthene, anthracene, benzo-[a]-pyrene (B-[a]-P) and perylene. The detection limits were 0.23, 7.90, 0.13, 1.10, 0.0083 ng ml(-1) for fluorene, acenaphthene, anthracene, B-[a]-P and perylene, respectively. The relative standard deviations were less than 5%.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "magnetic field (instrumental/analytical method)",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "Magnetic field effects–polarization–resonant synchronous fluorescence spectrometry was reported to effectively suppress the level and undulation of scattered light and was used for simultaneous determination of a mixture of five polynuclear aromatic hydrocarbons. Reported detection limits were 0.23, 7.90, 0.13, 1.10, and 0.0083 ng ml(-1) for fluorene, acenaphthene, anthracene, benzo-[a]-pyrene, and perylene, respectively, with relative standard deviations <5%.",
    "outcomes": [
      "Suppression of scattered light level and undulation in fluorescence spectrometry",
      "Detection limits for fluorene",
      "acenaphthene",
      "anthracene",
      "benzo-[a]-pyrene",
      "and perylene",
      "Relative standard deviation (precision)"
    ],
    "limitations": [
      "No biological or health outcomes assessed (analytical chemistry method).",
      "Magnetic field parameters (strength",
      "frequency) not reported in the abstract.",
      "Sample type and number of measurements/replicates not stated."
    ],
    "keywords": [
      "magnetic field effects",
      "polarization",
      "resonant synchronous fluorescence spectrometry",
      "scattered light suppression",
      "polynuclear aromatic hydrocarbons",
      "fluorene",
      "acenaphthene",
      "anthracene",
      "benzo[a]pyrene",
      "perylene",
      "detection limit",
      "precision"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": null,\n    \"source\": \"magnetic field (instrumental/analytical method)\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Suppression of scattered light level and undulation in fluorescence spectrometry\",\n    \"Detection limits for fluorene, acenaphthene, anthracene, benzo-[a]-pyrene, and perylene\",\n    \"Relative standard deviation (precision)\"\n  ],\n  \"main_findings\": \"Magnetic field effects–polarization–resonant synchronous fluorescence spectrometry was reported to effectively suppress the level and undulation of scattered light and was used for simultaneous determination of a mixture of five polynuclear aromatic hydrocarbons. Reported detection limits were 0.23, 7.90, 0.13, 1.10, and 0.0083 ng ml(-1) for fluorene, acenaphthene, anthracene, benzo-[a]-pyrene, and perylene, respectively, with relative standard deviations <5%.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No biological or health outcomes assessed (analytical chemistry method).\",\n    \"Magnetic field parameters (strength, frequency) not reported in the abstract.\",\n    \"Sample type and number of measurements/replicates not stated.\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"magnetic field effects\",\n    \"polarization\",\n    \"resonant synchronous fluorescence spectrometry\",\n    \"scattered light suppression\",\n    \"polynuclear aromatic hydrocarbons\",\n    \"fluorene\",\n    \"acenaphthene\",\n    \"anthracene\",\n    \"benzo[a]pyrene\",\n    \"perylene\",\n    \"detection limit\",\n    \"precision\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/18966418/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=4288",
  "updated": "2026-02-13 08:06:04"
}