{
  "id": 4362,
  "url": "https://nnemf.org/research/4362-effects-of-exposure-to-gsm-mobile-phone-base",
  "title": "Effects of exposure to GSM mobile phone base station signals on salivary cortisol, alpha-amylase, and immunoglobulin A.",
  "authors": [
    "Christoph Augner",
    "Gerhard W Hacker",
    "Gerd Oberfeld",
    "Matthias Florian",
    "Wolfgang Hitzl",
    "Jörg Hutter",
    "Gernot Pauser"
  ],
  "journal": "Biomedical and environmental sciences : BES",
  "year": "2010",
  "doi": "10.1016/s0895-3988(10)60053-0",
  "pmid": "20708499",
  "abstract": "OBJECTIVE: The present study aimed to test whether exposure to radiofrequency electromagnetic fields (RF-EMF) emitted by mobile phone base stations may have effects on salivary alpha-amylase, immunoglobulin A (IgA), and cortisol levels. METHODS: Fifty seven participants were randomly allocated to one of three different experimental scenarios (22 participants to scenario 1, 26 to scenario 2, and 9 to scenario 3). Each participant went through five 50-minute exposure sessions. The main RF-EMF source was a GSM-900-MHz antenna located at the outer wall of the building. In scenarios 1 and 2, the first, third, and fifth sessions were \"low\" (median power flux density 5.2 microW/m(2)) exposure. The second session was \"high\" (2126.8 microW/m(2)), and the fourth session was \"medium\" (153.6 microW/m(2)) in scenario 1, and vice versa in scenario 2. Scenario 3 had four \"low\" exposure conditions, followed by a \"high\" exposure condition. Biomedical parameters were collected by saliva samples three times a session. Exposure levels were created by shielding curtains. RESULTS: In scenario 3 from session 4 to session 5 (from \"low\" to \"high\" exposure), an increase of cortisol was detected, while in scenarios 1 and 2, a higher concentration of alpha-amylase related to the baseline was identified as compared to that in scenario 3. IgA concentration was not significantly related to the exposure. CONCLUSIONS: RF-EMF in considerably lower field densities than ICNIRP-guidelines may influence certain psychobiological stress markers.",
  "effect": "mixed",
  "evidence": "low",
  "extraction": {
    "studyType": "randomized_trial",
    "studyTypeLabel": "randomized trial",
    "effectDirection": "mixed",
    "evidenceLabel": "Low",
    "population": "57 participants",
    "sampleSize": "57",
    "exposure": "RF mobile phone base station · 900 MHz · five 50-minute exposure sessions",
    "confidencePct": "40",
    "peerReviewed": "yes",
    "mainFindings": "An increase in cortisol was detected when exposure changed from low to high in one scenario. Higher alpha-amylase concentrations were found in two scenarios compared to a third. IgA concentration was not significantly related to exposure.",
    "outcomes": [
      "salivary cortisol",
      "alpha-amylase",
      "immunoglobulin A (IgA)"
    ],
    "limitations": [
      "Small sample size in one scenario (9 participants)",
      "Only short-term exposure assessed",
      "Exposure levels were lower than ICNIRP guidelines"
    ],
    "keywords": [
      "RF-EMF",
      "GSM-900 MHz",
      "mobile phone base station",
      "cortisol",
      "alpha-amylase",
      "immunoglobulin A",
      "psychobiological stress markers"
    ],
    "hubs": [
      {
        "slug": "5g-policy",
        "weight": "0.7",
        "reason": "Study involves mobile phone base station RF exposure relevant to wireless communication policy."
      }
    ],
    "raw": "{\n  \"study_type\": \"randomized_trial\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"mobile phone base station\",\n    \"frequency_mhz\": 900,\n    \"sar_wkg\": null,\n    \"duration\": \"five 50-minute exposure sessions\"\n  },\n  \"population\": \"57 participants\",\n  \"sample_size\": 57,\n  \"outcomes\": [\n    \"salivary cortisol\",\n    \"alpha-amylase\",\n    \"immunoglobulin A (IgA)\"\n  ],\n  \"main_findings\": \"An increase in cortisol was detected when exposure changed from low to high in one scenario. Higher alpha-amylase concentrations were found in two scenarios compared to a third. IgA concentration was not significantly related to exposure.\",\n  \"effect_direction\": \"mixed\",\n  \"limitations\": [\n    \"Small sample size in one scenario (9 participants)\",\n    \"Only short-term exposure assessed\",\n    \"Exposure levels were lower than ICNIRP guidelines\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.4,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"RF-EMF\",\n    \"GSM-900 MHz\",\n    \"mobile phone base station\",\n    \"cortisol\",\n    \"alpha-amylase\",\n    \"immunoglobulin A\",\n    \"psychobiological stress markers\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"5g-policy\",\n      \"weight\": 0.3,\n      \"reason\": \"Study involves mobile phone base station RF exposure relevant to wireless communication policy.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/20708499/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=4362",
  "updated": "2026-02-14 06:55:05"
}