Share

A 1-μT extremely low-frequency electromagnetic field vs. sham control for mild-to-moderate hypertension: a double-blind, randomized study.

Tsutomu Nishimura, Harue Tada, Xinfeng Guo, Toshinori Murayama, Satoshi Teramukai, Hideyuki Okano, Junichi Yamada, Kaneo Mohri, Masanori Fukushima

PAPERpubmedHypertension research : official journal of the Japanese Society of Hypertension2011randomized trialEffect: benefitEvidence: Low

Abstract

The effects of extremely low-frequency electromagnetic fields (ELF-EMFs) on blood pressure (BP) are controversial. In this double-blind, randomized, sham-controlled study, we examined the effects of repeated exposure to a 1-μT ELF-EMF on BP in 20 humans with mild-to-moderate hypertension. Subjects were randomly assigned to either the ELF-EMF group or the sham group. Subjects in the ELF-EMF group were exposed to an ELF-EMF (6- and 8 Hz, respectively, peak magnetic field 1 μT, peak electric field 10 Vm(-1)) for at least two 10- to 15-min sessions per week, over a period of 4 weeks. In the sham group, the EMF-generating apparatus was not active. We obtained systolic and diastolic BP (SBP and DBP, respectively) measurements at registration and before and after each ELF-EMF exposure session. Subjects in the ELF-EMF and sham groups had mean ages of 52.8 and 55.1 years, and were exposed to a mean of 9.9 and 9.0 sessions, respectively. There was a significant difference between the ELF-EMF and sham groups with respect to change in SBP value between baseline and the end of the exposure regimen (P=0.02), but not with respect to change in DBP (P=0.21). There were no adverse events other than mild paresthesia of the hands of two subjects in the ELF-EMF group. Our results suggest that repeated exposure to an ELF-EMF has a BP-lowering effect on humans with mild-to-moderate hypertension.

AI evidence extraction

At a glance
Study type
randomized trial
Effect direction
benefit
Population
Humans with mild-to-moderate hypertension
Sample size
20
Exposure
ELF other · At least two 10–15 min sessions per week for 4 weeks (mean 9.9 sessions in ELF-EMF group; 9.0 in sham)
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Compared with sham, the ELF-EMF group showed a significant difference in change in systolic blood pressure from baseline to end of the 4-week regimen (P=0.02), but not in diastolic blood pressure (P=0.21). Two participants in the ELF-EMF group reported mild hand paresthesia; no other adverse events were reported.

Outcomes measured

  • Systolic blood pressure (SBP)
  • Diastolic blood pressure (DBP)
  • Adverse events (paresthesia)

Limitations

  • Small sample size (n=20)
  • Short intervention/follow-up period (4 weeks)

Suggested hubs

  • who-icnirp (0.7)
    Study concerns health effects of ELF electromagnetic field exposure, relevant to general EMF health guidance discussions.
View raw extracted JSON
{
  "study_type": "randomized_trial",
  "exposure": {
    "band": "ELF",
    "source": "other",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": "At least two 10–15 min sessions per week for 4 weeks (mean 9.9 sessions in ELF-EMF group; 9.0 in sham)"
  },
  "population": "Humans with mild-to-moderate hypertension",
  "sample_size": 20,
  "outcomes": [
    "Systolic blood pressure (SBP)",
    "Diastolic blood pressure (DBP)",
    "Adverse events (paresthesia)"
  ],
  "main_findings": "Compared with sham, the ELF-EMF group showed a significant difference in change in systolic blood pressure from baseline to end of the 4-week regimen (P=0.02), but not in diastolic blood pressure (P=0.21). Two participants in the ELF-EMF group reported mild hand paresthesia; no other adverse events were reported.",
  "effect_direction": "benefit",
  "limitations": [
    "Small sample size (n=20)",
    "Short intervention/follow-up period (4 weeks)"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "extremely low-frequency electromagnetic fields",
    "ELF-EMF",
    "1 μT",
    "6 Hz",
    "8 Hz",
    "hypertension",
    "blood pressure",
    "double-blind",
    "randomized",
    "sham-controlled",
    "systolic blood pressure",
    "diastolic blood pressure",
    "paresthesia"
  ],
  "suggested_hubs": [
    {
      "slug": "who-icnirp",
      "weight": 0.2,
      "reason": "Study concerns health effects of ELF electromagnetic field exposure, relevant to general EMF health guidance discussions."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 4475

A 1-μT extremely low-frequency electromagnetic field vs. sham control for mild-to-moderate hypertension: a double-blind, randomized study. · Non-native EMF