  "id": 4475,
  "url": "https://nnemf.org/research/4475-a-1-t-extremely-low-frequency-electromagnetic-field",
  "title": "A 1-μT extremely low-frequency electromagnetic field vs. sham control for mild-to-moderate hypertension: a double-blind, randomized study.",
  "authors": [
    "Tsutomu Nishimura",
    "Harue Tada",
    "Xinfeng Guo",
    "Toshinori Murayama",
    "Satoshi Teramukai",
    "Hideyuki Okano",
    "Junichi Yamada",
    "Kaneo Mohri",
    "Masanori Fukushima"
  ],
  "journal": "Hypertension research : official journal of the Japanese Society of Hypertension",
  "year": "2011",
  "doi": "10.1038/hr.2010.246",
  "pmid": "21248759",
  "abstract": "The effects of extremely low-frequency electromagnetic fields (ELF-EMFs) on blood pressure (BP) are controversial. In this double-blind, randomized, sham-controlled study, we examined the effects of repeated exposure to a 1-μT ELF-EMF on BP in 20 humans with mild-to-moderate hypertension. Subjects were randomly assigned to either the ELF-EMF group or the sham group. Subjects in the ELF-EMF group were exposed to an ELF-EMF (6- and 8 Hz, respectively, peak magnetic field 1 μT, peak electric field 10 Vm(-1)) for at least two 10- to 15-min sessions per week, over a period of 4 weeks. In the sham group, the EMF-generating apparatus was not active. We obtained systolic and diastolic BP (SBP and DBP, respectively) measurements at registration and before and after each ELF-EMF exposure session. Subjects in the ELF-EMF and sham groups had mean ages of 52.8 and 55.1 years, and were exposed to a mean of 9.9 and 9.0 sessions, respectively. There was a significant difference between the ELF-EMF and sham groups with respect to change in SBP value between baseline and the end of the exposure regimen (P=0.02), but not with respect to change in DBP (P=0.21). There were no adverse events other than mild paresthesia of the hands of two subjects in the ELF-EMF group. Our results suggest that repeated exposure to an ELF-EMF has a BP-lowering effect on humans with mild-to-moderate hypertension.",
  "effect": "benefit",
  "evidence": "low",
  "extraction": {
    "studyType": "randomized_trial",
    "studyTypeLabel": "randomized trial",
    "effectDirection": "benefit",
    "evidenceLabel": "Low",
    "population": "Humans with mild-to-moderate hypertension",
    "sampleSize": "20",
    "exposure": "ELF other · At least two 10–15 min sessions per week for 4 weeks (mean 9.9 sessions in ELF-EMF group; 9.0 in sham)",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "Compared with sham, the ELF-EMF group showed a significant difference in change in systolic blood pressure from baseline to end of the 4-week regimen (P=0.02), but not in diastolic blood pressure (P=0.21). Two participants in the ELF-EMF group reported mild hand paresthesia; no other adverse events were reported.",
    "outcomes": [
      "Systolic blood pressure (SBP)",
      "Diastolic blood pressure (DBP)",
      "Adverse events (paresthesia)"
    ],
    "limitations": [
      "Small sample size (n=20)",
      "Short intervention/follow-up period (4 weeks)"
    ],
    "keywords": [
      "extremely low-frequency electromagnetic fields",
      "ELF-EMF",
      "1 μT",
      "6 Hz",
      "8 Hz",
      "hypertension",
      "blood pressure",
      "double-blind",
      "randomized",
      "sham-controlled",
      "systolic blood pressure",
      "diastolic blood pressure",
      "paresthesia"
    ],
    "hubs": [
      {
        "slug": "who-icnirp",
        "weight": "0.7",
        "reason": "Study concerns health effects of ELF electromagnetic field exposure, relevant to general EMF health guidance discussions."
      }
    ],
    "raw": "{\n  \"study_type\": \"randomized_trial\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": \"other\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"At least two 10–15 min sessions per week for 4 weeks (mean 9.9 sessions in ELF-EMF group; 9.0 in sham)\"\n  },\n  \"population\": \"Humans with mild-to-moderate hypertension\",\n  \"sample_size\": 20,\n  \"outcomes\": [\n    \"Systolic blood pressure (SBP)\",\n    \"Diastolic blood pressure (DBP)\",\n    \"Adverse events (paresthesia)\"\n  ],\n  \"main_findings\": \"Compared with sham, the ELF-EMF group showed a significant difference in change in systolic blood pressure from baseline to end of the 4-week regimen (P=0.02), but not in diastolic blood pressure (P=0.21). Two participants in the ELF-EMF group reported mild hand paresthesia; no other adverse events were reported.\",\n  \"effect_direction\": \"benefit\",\n  \"limitations\": [\n    \"Small sample size (n=20)\",\n    \"Short intervention/follow-up period (4 weeks)\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"extremely low-frequency electromagnetic fields\",\n    \"ELF-EMF\",\n    \"1 μT\",\n    \"6 Hz\",\n    \"8 Hz\",\n    \"hypertension\",\n    \"blood pressure\",\n    \"double-blind\",\n    \"randomized\",\n    \"sham-controlled\",\n    \"systolic blood pressure\",\n    \"diastolic blood pressure\",\n    \"paresthesia\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"who-icnirp\",\n      \"weight\": 0.2,\n      \"reason\": \"Study concerns health effects of ELF electromagnetic field exposure, relevant to general EMF health guidance discussions.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/21248759/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=4475",
  "updated": "2026-02-14 07:55:41"
}