Exposure of rats to extremely low-frequency electromagnetic fields (ELF-EMF) alters cytokines production.

Iraj Salehi, Karim Ghazikhanlou Sani, Alireza Zamani

PAPERpubmedElectromagnetic biology and medicine2013Animal studyEffect: mixedEvidence: Low

Abstract

Investigations indicate a potential link between exposure to extremely low-frequency electromagnetic field (ELF-EMF) and some cancers. Carcinogenesis of ELF-EMF may be mediated by effect on the immune system. During an immune response, naïve T cells differentiate to effector type 1 helper T cells (T(H)1), T(H)2, or T(H)17 subsets according to existence of different cytokines and T(H)1 is important in defense against tumors. Therefore, it will be reasonable to test whether ELF-EMF can change cytokines like interferon gamma (IFN-γ), interleukin-4 (IL-4), IL-6, and IL-12 that regulate T(H)1/T(H)2/T(H)17 balance. Forty adult male rats were randomly separated into ELF-EMF-exposed and sham-exposed control groups. The ELF-EMF group was exposed to a flux density of 100 μT, frequency 50 Hz, 2 h/day for 3 months. The controls were placed in identical chamber without ELF-EMF. The results showed there were no significant differences between the mean mass of rats, thymuses, and spleens in ELF-EMF exposed group compared with controls. Serum IL-12 level was decreased from 418 ± 47 pg/ml in controls to 300 ± 23 pg/ml (p < 0.05) in ELF-EMF-exposed group. Phytohemagglutinin activated of in vitro production of IL-6 by the whole spleen culture (1356 ± 92 pg/ml) and total blood culture (418 ± 40 pg/ml) of ELF-EMF-exposed rats were higher (p < 0.001) comparing with controls (905 ± 74 pg/ml), (182 ± 26 pg/ml), respectively. However, the levels of IFN-γ, IL-4, and IL-6 of serum and IFN-γ, IL-4, and IL-12 in spleen culture and total blood culture of two groups were not significantly different. It seems that ELF-EMF may change T(H)1/T(H)2/T(H)17 balance toward down regulation of T(H)1 and upregulation T(H)17 type responses.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
mixed
Population
Forty adult male rats
Sample size
40
Exposure
ELF · 0.05 MHz · 2 h/day for 3 months
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Rats exposed to 50 Hz ELF-EMF at 100 μT for 2 h/day for 3 months showed no significant differences in body, thymus, or spleen mass versus sham controls. Serum IL-12 was lower in exposed rats (300±23 pg/ml) than controls (418±47 pg/ml; p<0.05), and phytohemagglutinin-stimulated IL-6 production was higher in spleen and blood cultures from exposed rats (p<0.001), while several other cytokine measures (including IFN-γ and IL-4) were not significantly different.

Outcomes measured

  • Serum cytokines (IL-12
  • IFN-γ
  • IL-4
  • IL-6)
  • In vitro cytokine production in whole spleen culture and total blood culture (IL-6
  • IL-12) after phytohemagglutinin activation
  • Body mass
  • Thymus mass
  • Spleen mass

Limitations

  • Only adult male rats were studied
  • Some outcomes showed no significant differences while others did
  • suggesting outcome-specific effects
  • In vitro cytokine production assays may not directly reflect in vivo immune function
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "ELF",
    "source": null,
    "frequency_mhz": 0.05,
    "sar_wkg": null,
    "duration": "2 h/day for 3 months"
  },
  "population": "Forty adult male rats",
  "sample_size": 40,
  "outcomes": [
    "Serum cytokines (IL-12, IFN-γ, IL-4, IL-6)",
    "In vitro cytokine production in whole spleen culture and total blood culture (IL-6, IFN-γ, IL-4, IL-12) after phytohemagglutinin activation",
    "Body mass",
    "Thymus mass",
    "Spleen mass"
  ],
  "main_findings": "Rats exposed to 50 Hz ELF-EMF at 100 μT for 2 h/day for 3 months showed no significant differences in body, thymus, or spleen mass versus sham controls. Serum IL-12 was lower in exposed rats (300±23 pg/ml) than controls (418±47 pg/ml; p<0.05), and phytohemagglutinin-stimulated IL-6 production was higher in spleen and blood cultures from exposed rats (p<0.001), while several other cytokine measures (including IFN-γ and IL-4) were not significantly different.",
  "effect_direction": "mixed",
  "limitations": [
    "Only adult male rats were studied",
    "Some outcomes showed no significant differences while others did, suggesting outcome-specific effects",
    "In vitro cytokine production assays may not directly reflect in vivo immune function"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "ELF-EMF",
    "50 Hz",
    "100 μT",
    "rats",
    "cytokines",
    "IL-12",
    "IL-6",
    "IFN-γ",
    "IL-4",
    "T(H)1",
    "T(H)2",
    "T(H)17",
    "immune system"
  ],
  "suggested_hubs": [
    {
      "slug": "elf-emf",
      "weight": 0.9,
      "reason": "Animal experiment with extremely low-frequency EMF exposure (50 Hz, 100 μT) assessing immune/cytokine outcomes."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 4502

Exposure of rats to extremely low-frequency electromagnetic fields (ELF-EMF) alters cytokines production. · Non-native EMF