  "id": 4502,
  "url": "https://nnemf.org/research/4502-exposure-of-rats-to-extremely-low-frequency-electromagnetic",
  "title": "Exposure of rats to extremely low-frequency electromagnetic fields (ELF-EMF) alters cytokines production.",
  "authors": [
    "Iraj Salehi",
    "Karim Ghazikhanlou Sani",
    "Alireza Zamani"
  ],
  "journal": "Electromagnetic biology and medicine",
  "year": "2013",
  "doi": "10.3109/15368378.2012.692343",
  "pmid": "23046051",
  "abstract": "Investigations indicate a potential link between exposure to extremely low-frequency electromagnetic field (ELF-EMF) and some cancers. Carcinogenesis of ELF-EMF may be mediated by effect on the immune system. During an immune response, naïve T cells differentiate to effector type 1 helper T cells (T(H)1), T(H)2, or T(H)17 subsets according to existence of different cytokines and T(H)1 is important in defense against tumors. Therefore, it will be reasonable to test whether ELF-EMF can change cytokines like interferon gamma (IFN-γ), interleukin-4 (IL-4), IL-6, and IL-12 that regulate T(H)1/T(H)2/T(H)17 balance. Forty adult male rats were randomly separated into ELF-EMF-exposed and sham-exposed control groups. The ELF-EMF group was exposed to a flux density of 100 μT, frequency 50 Hz, 2 h/day for 3 months. The controls were placed in identical chamber without ELF-EMF. The results showed there were no significant differences between the mean mass of rats, thymuses, and spleens in ELF-EMF exposed group compared with controls. Serum IL-12 level was decreased from 418 ± 47 pg/ml in controls to 300 ± 23 pg/ml (p < 0.05) in ELF-EMF-exposed group. Phytohemagglutinin activated of in vitro production of IL-6 by the whole spleen culture (1356 ± 92 pg/ml) and total blood culture (418 ± 40 pg/ml) of ELF-EMF-exposed rats were higher (p < 0.001) comparing with controls (905 ± 74 pg/ml), (182 ± 26 pg/ml), respectively. However, the levels of IFN-γ, IL-4, and IL-6 of serum and IFN-γ, IL-4, and IL-12 in spleen culture and total blood culture of two groups were not significantly different. It seems that ELF-EMF may change T(H)1/T(H)2/T(H)17 balance toward down regulation of T(H)1 and upregulation T(H)17 type responses.",
  "effect": "mixed",
  "evidence": "low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "mixed",
    "evidenceLabel": "Low",
    "population": "Forty adult male rats",
    "sampleSize": "40",
    "exposure": "ELF · 0.05 MHz · 2 h/day for 3 months",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "Rats exposed to 50 Hz ELF-EMF at 100 μT for 2 h/day for 3 months showed no significant differences in body, thymus, or spleen mass versus sham controls. Serum IL-12 was lower in exposed rats (300±23 pg/ml) than controls (418±47 pg/ml; p<0.05), and phytohemagglutinin-stimulated IL-6 production was higher in spleen and blood cultures from exposed rats (p<0.001), while several other cytokine measures (including IFN-γ and IL-4) were not significantly different.",
    "outcomes": [
      "Serum cytokines (IL-12",
      "IFN-γ",
      "IL-4",
      "IL-6)",
      "In vitro cytokine production in whole spleen culture and total blood culture (IL-6",
      "IL-12) after phytohemagglutinin activation",
      "Body mass",
      "Thymus mass",
      "Spleen mass"
    ],
    "limitations": [
      "Only adult male rats were studied",
      "Some outcomes showed no significant differences while others did",
      "suggesting outcome-specific effects",
      "In vitro cytokine production assays may not directly reflect in vivo immune function"
    ],
    "keywords": [
      "ELF-EMF",
      "50 Hz",
      "100 μT",
      "rats",
      "cytokines",
      "IL-12",
      "IL-6",
      "IFN-γ",
      "IL-4",
      "T(H)1",
      "T(H)2",
      "T(H)17",
      "immune system"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": null,\n    \"frequency_mhz\": 0.05,\n    \"sar_wkg\": null,\n    \"duration\": \"2 h/day for 3 months\"\n  },\n  \"population\": \"Forty adult male rats\",\n  \"sample_size\": 40,\n  \"outcomes\": [\n    \"Serum cytokines (IL-12, IFN-γ, IL-4, IL-6)\",\n    \"In vitro cytokine production in whole spleen culture and total blood culture (IL-6, IFN-γ, IL-4, IL-12) after phytohemagglutinin activation\",\n    \"Body mass\",\n    \"Thymus mass\",\n    \"Spleen mass\"\n  ],\n  \"main_findings\": \"Rats exposed to 50 Hz ELF-EMF at 100 μT for 2 h/day for 3 months showed no significant differences in body, thymus, or spleen mass versus sham controls. Serum IL-12 was lower in exposed rats (300±23 pg/ml) than controls (418±47 pg/ml; p<0.05), and phytohemagglutinin-stimulated IL-6 production was higher in spleen and blood cultures from exposed rats (p<0.001), while several other cytokine measures (including IFN-γ and IL-4) were not significantly different.\",\n  \"effect_direction\": \"mixed\",\n  \"limitations\": [\n    \"Only adult male rats were studied\",\n    \"Some outcomes showed no significant differences while others did, suggesting outcome-specific effects\",\n    \"In vitro cytokine production assays may not directly reflect in vivo immune function\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"ELF-EMF\",\n    \"50 Hz\",\n    \"100 μT\",\n    \"rats\",\n    \"cytokines\",\n    \"IL-12\",\n    \"IL-6\",\n    \"IFN-γ\",\n    \"IL-4\",\n    \"T(H)1\",\n    \"T(H)2\",\n    \"T(H)17\",\n    \"immune system\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"elf-emf\",\n      \"weight\": 0.9,\n      \"reason\": \"Animal experiment with extremely low-frequency EMF exposure (50 Hz, 100 μT) assessing immune/cytokine outcomes.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/23046051/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=4502",
  "updated": "2026-02-14 07:59:04"
}