  "id": 4571,
  "url": "https://nnemf.org/research/4571-use-of-portable-exposure-meters-for-comparing-mobile",
  "title": "Use of portable exposure meters for comparing mobile phone base station radiation in different types of areas in the cities of Basel and Amsterdam.",
  "authors": [
    "Damiano Urbinello",
    "Anke Huss",
    "Johan Beekhuizen",
    "Roel Vermeulen",
    "Martin Röösli"
  ],
  "journal": "The Science of the total environment",
  "year": "2014",
  "doi": "10.1016/j.scitotenv.2013.09.012",
  "pmid": "24091124",
  "abstract": "BACKGROUND: Radiofrequency electromagnetic fields (RF-EMF) are highly variable and differ considerably within as well as between areas. Exposure assessment studies characterizing spatial and temporal variation are limited so far. Our objective was to evaluate sources of data variability and the repeatability of daily measurements using portable exposure meters (PEMs). METHODS: Data were collected at 12 days between November 2010 and January 2011 with PEMs in four different types of urban areas in the cities of Basel (BSL) and Amsterdam (AMS). RESULTS: Exposure from mobile phone base stations ranged from 0.30 to 0.53 V/m in downtown and business areas and in residential areas from 0.09 to 0.41 V/m. Analysis of variance (ANOVA) demonstrated that measurements from various days were highly reproducible (measurement duration of approximately 30 min) with only 0.6% of the variance of all measurements from mobile phone base station radiation being explained by the measurement day and only 0.2% by the measurement time (morning, noon, afternoon), whereas type of area (30%) and city (50%) explained most of the data variability. CONCLUSIONS: We conclude that mobile monitoring of exposure from mobile phone base station radiation with PEMs is useful due to the high repeatability of mobile phone base station exposure levels, despite the high spatial variation.",
  "effect": "unclear",
  "evidence": "moderate",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "unclear",
    "evidenceLabel": "Moderate",
    "population": "—",
    "sampleSize": "—",
    "exposure": "RF mobile phone base station · ~30 min per measurement; data collected on 12 days (Nov 2010–Jan 2011)",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "Mobile phone base station exposure ranged from 0.30 to 0.53 V/m in downtown/business areas and from 0.09 to 0.41 V/m in residential areas. ANOVA indicated high reproducibility across days and times: measurement day explained 0.6% of variance and time of day explained 0.2%, while type of area explained 30% and city explained 50% of variability.",
    "outcomes": [
      "RF-EMF exposure levels from mobile phone base stations (V/m)",
      "Spatial/temporal variability of measurements",
      "Repeatability/reproducibility of daily measurements using portable exposure meters (PEMs)"
    ],
    "limitations": [],
    "keywords": [
      "radiofrequency electromagnetic fields",
      "RF-EMF",
      "portable exposure meters",
      "PEM",
      "mobile monitoring",
      "base station",
      "exposure assessment",
      "spatial variation",
      "temporal variation",
      "repeatability",
      "Basel",
      "Amsterdam",
      "ANOVA"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Uses portable exposure meters for mobile monitoring in urban areas; not explicitly occupational but relates to measurement methodology."
      }
    ],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"mobile phone base station\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"~30 min per measurement; data collected on 12 days (Nov 2010–Jan 2011)\"\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"RF-EMF exposure levels from mobile phone base stations (V/m)\",\n    \"Spatial/temporal variability of measurements\",\n    \"Repeatability/reproducibility of daily measurements using portable exposure meters (PEMs)\"\n  ],\n  \"main_findings\": \"Mobile phone base station exposure ranged from 0.30 to 0.53 V/m in downtown/business areas and from 0.09 to 0.41 V/m in residential areas. ANOVA indicated high reproducibility across days and times: measurement day explained 0.6% of variance and time of day explained 0.2%, while type of area explained 30% and city explained 50% of variability.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [],\n  \"evidence_strength\": \"moderate\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"radiofrequency electromagnetic fields\",\n    \"RF-EMF\",\n    \"portable exposure meters\",\n    \"PEM\",\n    \"mobile monitoring\",\n    \"base station\",\n    \"exposure assessment\",\n    \"spatial variation\",\n    \"temporal variation\",\n    \"repeatability\",\n    \"Basel\",\n    \"Amsterdam\",\n    \"ANOVA\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.15,\n      \"reason\": \"Uses portable exposure meters for mobile monitoring in urban areas; not explicitly occupational but relates to measurement methodology.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/24091124/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=4571",
  "updated": "2026-02-14 08:00:19"
}