  "id": 46,
  "url": "https://nnemf.org/research/46-electromagnetic-field-exposure-in-the-public-space-of",
  "title": "Electromagnetic Field Exposure in the Public Space of the Slovakian",
  "authors": [],
  "journal": "Scientific Letters of the University of Zilina",
  "year": "2023",
  "doi": "10.26552/com.c.2023.014",
  "pmid": null,
  "abstract": "Electromagnetic Field Exposure in the Public Space of the Slovakian City Trnka M, Gálik P, Kráľová E, Važan R. Electromagnetic Field Exposure in the Public Space of the Slovakian City. Scientific Letters of the University of Zilina 2023, 25(1):G1-G6. doi: 10.26552/com.C.2023.014 The main objective of our research was to map the exposure to electromagnetic smog in the frequented space of shopping centres in the city of Bratislava and to compare our results to the actual hygienic limits. The measurements of the low- and high-frequency electromagnetic fields were performed at different places in shopping centres. Our results did not exceed the Slovak current limits in any of the measurements. However, almost all of them markedly exceed new permitted limits according to EUROPAEM. Based on our results, stricter limits in many European countries and increasing evidence on possible harmfulness of long-term exposures to artificial electromagnetic fields, preventive carefulness can be recommended - to support the research in this field, to prepare professional public education and possibly to prepare the stricter Slovak exposure limits. : https://komunikacie.uniza.sk/pdfs/csl/2023/01/08.pdf",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "ELF <1 MHz",
    "confidencePct": "74",
    "peerReviewed": "unknown",
    "mainFindings": "Measurements of low- and high-frequency electromagnetic fields at different places in shopping centres in Bratislava did not exceed current Slovak limits in any measurement. The authors report that almost all measurements markedly exceeded newer permitted limits according to EUROPAEM.",
    "outcomes": [
      "Measured low-frequency electromagnetic fields in shopping centres",
      "Measured high-frequency electromagnetic fields in shopping centres",
      "Comparison of measured levels to Slovak hygienic limits",
      "Comparison of measured levels to EUROPAEM permitted limits"
    ],
    "limitations": [
      "No measurement details provided in abstract (instrumentation",
      "protocols",
      "specific frequencies",
      "units",
      "time of day)",
      "No sample size/number of measurement points reported",
      "No health outcomes assessed",
      "exposure mapping only",
      "EUROPAEM limits referenced without details in abstract"
    ],
    "keywords": [
      "electromagnetic field",
      "electromagnetic smog",
      "exposure assessment",
      "shopping centres",
      "public space",
      "Bratislava",
      "Slovakia",
      "hygienic limits",
      "EUROPAEM"
    ],
    "hubs": [
      {
        "slug": "who-icnirp",
        "weight": "0.7",
        "reason": "Compares measured public exposures to national hygienic limits and discusses stricter limits; relevant to exposure-limit frameworks."
      }
    ],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": \"ELF and RF\",\n    \"source\": \"public space (shopping centres)\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Measured low-frequency electromagnetic fields in shopping centres\",\n    \"Measured high-frequency electromagnetic fields in shopping centres\",\n    \"Comparison of measured levels to Slovak hygienic limits\",\n    \"Comparison of measured levels to EUROPAEM permitted limits\"\n  ],\n  \"main_findings\": \"Measurements of low- and high-frequency electromagnetic fields at different places in shopping centres in Bratislava did not exceed current Slovak limits in any measurement. The authors report that almost all measurements markedly exceeded newer permitted limits according to EUROPAEM.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No measurement details provided in abstract (instrumentation, protocols, specific frequencies, units, time of day)\",\n    \"No sample size/number of measurement points reported\",\n    \"No health outcomes assessed; exposure mapping only\",\n    \"EUROPAEM limits referenced without details in abstract\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"unknown\",\n  \"keywords\": [\n    \"electromagnetic field\",\n    \"electromagnetic smog\",\n    \"exposure assessment\",\n    \"shopping centres\",\n    \"public space\",\n    \"Bratislava\",\n    \"Slovakia\",\n    \"hygienic limits\",\n    \"EUROPAEM\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"who-icnirp\",\n      \"weight\": 0.3,\n      \"reason\": \"Compares measured public exposures to national hygienic limits and discusses stricter limits; relevant to exposure-limit frameworks.\"\n    }\n  ]\n}"
  },
  "synthesis": "1. What they did: In 2023, researchers mapped electromagnetic fields in frequented public space inside shopping centres in Bratislava, Slovakia. They took readings of low-frequency fields, meaning extremely low frequency fields of the kind associated with electrical power systems, and of high-frequency fields, meaning radiofrequency fields of the kind used by wireless signals. Readings were made at different places within the centres. The stated aim was to describe that public-space exposure and to set the readings against current Slovak hygienic limits and against newer permitted limits from EUROPAEM, the European Academy for Environmental Medicine guidance named in the paper.\n\n2. What they found: None of the measurements exceeded the current Slovak hygienic limits. Almost all of the same measurements markedly exceeded the newer permitted limits according to EUROPAEM. The abstract gives no numeric field strengths, no power-density figures, and no specific absorption rate, the rate at which the body absorbs radiofrequency energy.\n\n3. How it connects: What this study supplies is the outside field itself: extremely low frequency and radiofrequency levels in occupied indoor public space, judged against two exposure benchmarks. In the framework, that outside field is the input. Density gating means the same external exposure does not land the same way in every receiver, because the response depends on the receiving cell's machinery and reserve, so tissues, life stages, and existing vulnerabilities can differ. This paper stops at that input. It does not report calcium-signal timing, voltage-sensing channel behavior at the S4 segment (the charged part of an ion channel that detects voltage), mitochondrial energy and redox output, or spin chemistry, so those steps are not assigned to this result. No stored framework statement was tagged to this study. The related school survey shares only the EUROPAEM exposure-guidance tag and is an environmental radiofrequency map, not a shared cellular step, so it is not linked as upstream, downstream, or parallel biology.\n\n4. Limits: Exact frequencies, modulation or pulsing, reading duration, numeric field levels, power density, and specific absorption rate are not in the record.",
  "synthesisStatus": "stored",
  "originalHref": "https://komunikacie.uniza.sk/pdfs/csl/2023/01/08.pdf",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=46",
  "updated": "2026-02-12 19:25:12"
}