  "id": 4629,
  "url": "https://nnemf.org/research/4629-geospatial-modelling-of-electromagnetic-fields-from-mobile-phone",
  "title": "Geospatial modelling of electromagnetic fields from mobile phone base stations.",
  "authors": [
    "J Beekhuizen",
    "R Vermeulen",
    "H Kromhout",
    "A Bürgi",
    "A Huss"
  ],
  "journal": "The Science of the total environment",
  "year": "2013",
  "doi": "10.1016/j.scitotenv.2012.12.020",
  "pmid": "23333516",
  "abstract": "There is concern that exposure to radio frequency electromagnetic fields (RF-EMF) from mobile phone base stations might lead to adverse health effects. In order to assess potential health risks, reliable exposure assessment is necessary. Geospatial exposure modelling is a promising approach to quantify ambient exposure to RF-EMF for epidemiological studies involving large populations. We modelled RF-EMF for Amsterdam, The Netherlands by using a 3D RF-EMF model (NISMap). We subsequently compared modelled results to RF-EMF measurements in five areas with differing built-up characteristics (e.g., low-rise residential, high-rise commercial). We performed, in each area, repeated continuous measurements along a predefined ~2 km long path. This mobile monitoring approach captures the high spatial variability in electric field strengths. The modelled values were in good agreement with the measurements. We found a Spearman correlation of 0.86 for GSM900 and 0.85 for UMTS between modelled and measured values. The average measured GSM900 field strength was 0.21 V/m, and UMTS 0.09 V/m. The model underestimated the GSM900 field strengths by 0.07 V/m, and slightly overestimated the UMTS field strengths by 0.01 V/m. NISMap provides a reliable way of assessing environmental RF-EMF exposure for epidemiological studies of RF-EMF and health in urban areas.",
  "effect": "unclear",
  "evidence": "moderate",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "unclear",
    "evidenceLabel": "Moderate",
    "population": "—",
    "sampleSize": "—",
    "exposure": "RF 100–3000 MHz",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "A 3D geospatial RF-EMF model (NISMap) for Amsterdam showed good agreement with mobile monitoring measurements across five urban areas. Spearman correlations between modelled and measured values were 0.86 (GSM900) and 0.85 (UMTS); the model underestimated GSM900 by 0.07 V/m and slightly overestimated UMTS by 0.01 V/m.",
    "outcomes": [
      "Modelled vs measured RF-EMF electric field strength agreement (GSM900",
      "UMTS)",
      "Spearman correlation between modelled and measured values",
      "Average measured field strengths (V/m)",
      "Model bias (under/overestimation in V/m)"
    ],
    "limitations": [],
    "keywords": [
      "RF-EMF",
      "radiofrequency",
      "mobile phone base stations",
      "geospatial modelling",
      "3D model",
      "NISMap",
      "exposure assessment",
      "Amsterdam",
      "GSM900",
      "UMTS",
      "mobile monitoring",
      "electric field strength"
    ],
    "hubs": [
      {
        "slug": "who-icnirp",
        "weight": "0.7",
        "reason": "Focuses on environmental RF-EMF exposure assessment relevant to epidemiological risk assessment frameworks."
      }
    ],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"mobile phone base station\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Modelled vs measured RF-EMF electric field strength agreement (GSM900, UMTS)\",\n    \"Spearman correlation between modelled and measured values\",\n    \"Average measured field strengths (V/m)\",\n    \"Model bias (under/overestimation in V/m)\"\n  ],\n  \"main_findings\": \"A 3D geospatial RF-EMF model (NISMap) for Amsterdam showed good agreement with mobile monitoring measurements across five urban areas. Spearman correlations between modelled and measured values were 0.86 (GSM900) and 0.85 (UMTS); the model underestimated GSM900 by 0.07 V/m and slightly overestimated UMTS by 0.01 V/m.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [],\n  \"evidence_strength\": \"moderate\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"RF-EMF\",\n    \"radiofrequency\",\n    \"mobile phone base stations\",\n    \"geospatial modelling\",\n    \"3D model\",\n    \"NISMap\",\n    \"exposure assessment\",\n    \"Amsterdam\",\n    \"GSM900\",\n    \"UMTS\",\n    \"mobile monitoring\",\n    \"electric field strength\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"who-icnirp\",\n      \"weight\": 0.2,\n      \"reason\": \"Focuses on environmental RF-EMF exposure assessment relevant to epidemiological risk assessment frameworks.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/23333516/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=4629",
  "updated": "2026-02-14 08:01:03"
}