{
  "id": 4634,
  "url": "https://nnemf.org/research/4634-effects-of-low-level-electromagnetic-field-exposure-at",
  "title": "Effects of low level electromagnetic field exposure at 2.45 GHz on rat cornea.",
  "authors": [
    "Ayşegül Akar",
    "M Önder Karayiğit",
    "Durmuş Bolat",
    "M Erdem Gültiken",
    "Murat Yarim",
    "Gastone Castellani"
  ],
  "journal": "International journal of radiation biology",
  "year": "2013",
  "doi": "10.3109/09553002.2013.754557",
  "pmid": "23206266",
  "abstract": "PURPOSE: To investigate the effects of low level electromagnetic field (low level-EMF) exposure, as frequently encountered in daily life, on the normal rat cornea using histological and stereological method. METHODS: Twenty-two adult male Wistar rats were randomly divided into two groups: Study group (n = 11) and control group (n = 11). Rats in the study group were exposed to 2.45 GHz microwave (MW) radiation (11.96 ± 0.89 V/m), 0.25 W/kg specific absorption rate (SAR) for 2 hours each day for 21 days. The corneal thickness and the anterior epithelium corneal thickness were measured using two different methods. RESULTS: Using the histological method, the mean corneal thicknesses in the control and study group were 278.9 ± 54.5 μm, and 272.4 ± 85.6 μm, respectively. There was no statistically significant difference between the groups (p > 0.05). The anterior corneal epithelium thickness was 28.1 ± 4.9 μm in the control group and 31.7 ± 5.5 μm in the study group. There were statistically differences between the groups with regard to the thickness of anterior epithelium (p < 0.05). In the measurement made by the stereological method, the percentage of the cornea occupied by anterior corneal epithelium was 15.94% in the control group and 17.9% in the study group. Despite the fact that there was a relation between increased anterior epithelial area (AEA) and radiation exposure, no statistically significant relationship in area fraction of each compartment was found between the control and study groups. CONCLUSIONS: Results of this preliminary study show that exposure to MW radiation might cause alterations in the rat cornea.",
  "effect": "mixed",
  "evidence": "low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "mixed",
    "evidenceLabel": "Low",
    "population": "Adult male Wistar rats",
    "sampleSize": "22",
    "exposure": "microwave · 2450 MHz · 0.25 W/kg · 2 hours/day for 21 days",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "Rats exposed to 2.45 GHz microwave radiation (11.96 ± 0.89 V/m; SAR 0.25 W/kg) showed no statistically significant difference in mean corneal thickness versus controls (p > 0.05). Anterior corneal epithelium thickness was higher in the exposed group than controls by histological measurement (p < 0.05), while stereological assessment found no statistically significant differences in area fractions of corneal compartments.",
    "outcomes": [
      "Corneal thickness",
      "Anterior corneal epithelium thickness",
      "Percentage of cornea occupied by anterior corneal epithelium (area fraction/AEA)"
    ],
    "limitations": [
      "Described as a preliminary study",
      "Small sample size (n=11 per group)"
    ],
    "keywords": [
      "2.45 GHz",
      "microwave radiation",
      "low level EMF",
      "SAR",
      "rat",
      "cornea",
      "histology",
      "stereology",
      "corneal thickness",
      "anterior epithelium"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"microwave\",\n    \"source\": null,\n    \"frequency_mhz\": 2450,\n    \"sar_wkg\": 0.25,\n    \"duration\": \"2 hours/day for 21 days\"\n  },\n  \"population\": \"Adult male Wistar rats\",\n  \"sample_size\": 22,\n  \"outcomes\": [\n    \"Corneal thickness\",\n    \"Anterior corneal epithelium thickness\",\n    \"Percentage of cornea occupied by anterior corneal epithelium (area fraction/AEA)\"\n  ],\n  \"main_findings\": \"Rats exposed to 2.45 GHz microwave radiation (11.96 ± 0.89 V/m; SAR 0.25 W/kg) showed no statistically significant difference in mean corneal thickness versus controls (p > 0.05). Anterior corneal epithelium thickness was higher in the exposed group than controls by histological measurement (p < 0.05), while stereological assessment found no statistically significant differences in area fractions of corneal compartments.\",\n  \"effect_direction\": \"mixed\",\n  \"limitations\": [\n    \"Described as a preliminary study\",\n    \"Small sample size (n=11 per group)\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"2.45 GHz\",\n    \"microwave radiation\",\n    \"low level EMF\",\n    \"SAR\",\n    \"rat\",\n    \"cornea\",\n    \"histology\",\n    \"stereology\",\n    \"corneal thickness\",\n    \"anterior epithelium\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/23206266/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=4634",
  "updated": "2026-02-14 08:01:07"
}