EMF biological effects
Share

Electromagnetic field exposure to human head model with various metal objects at sub-6 GHz frequencies

PAPERmanualElectromagnetic biology and medicine2023engineeringEffect: mixedEvidence: Low

Abstract

Electromagnetic field exposure to human head model with various metal objects at sub-6 GHz frequencies İl N, Ateş K, Özen Ş. Electromagnetic field exposure to human head model with various metal objects at sub-6 GHz frequencies. Electromagn Biol Med. 2023 Jun 4:1-9. doi: 10.1080/15368378.2023.2220736. Abstract In recent years, the interactions of metal objects in human body with electromagnetic fields caused by devices working at fifth-generation (5G) frequencies have been studied by various researchers. A motivation behind this research was to evaluate the human body absorption of electromagnetic energy operating at sub-6 GHz 5G applications. According to this, the specific absorption rate (SAR) caused by new generation mobile phones was investigated in human heads wearing metal-framed spectacles and having metallic implants or earrings to analyse electromagnetic field exposure. A realistic human head model, including some metal objects, was numerically calculated, and analysed in terms of non-ionizing dosimetry. Simulations were carried out with the finite integration technique (FIT) based commercial software in the frequencies of 0.9, 1.8, 2.1, 2.45, 3.5 and 5 GHz, respectively. The maximum SAR of 14 × 10-5 W/kg for 10 g average tissue was calculated at 2.45 GHz frequency in the head model with earrings. The highest electric field strength of 0.52 V/m was observed at a 1.8 GHz frequency in the head model with all metal objects equipped. Results show that metal objects such as spectacles, dental implants and earrings can cause an increase in the SAR values for external biological tissues, and metal objects can behave as a kind of shield for deeper tissues. However, the obtained values are below the limits of international organisations. pubmed.ncbi.nlm.nih.gov

AI evidence extraction

At a glance
Study type
engineering
Effect direction
mixed
Population
Human head model (realistic numerical model)
Sample size
—
Exposure
RF mobile phone · 0.00014 W/kg
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

Numerical simulations (0.9, 1.8, 2.1, 2.45, 3.5, 5 GHz) of a realistic human head model with metal-framed spectacles, metallic implants, and/or earrings reported a maximum 10 g SAR of 14 × 10^-5 W/kg at 2.45 GHz in the model with earrings, and a highest electric field strength of 0.52 V/m at 1.8 GHz with all metal objects. The authors report that metal objects can increase SAR in external tissues and may act as shielding for deeper tissues, with values below international limits.

Outcomes measured

  • Specific absorption rate (SAR) (10 g average tissue)
  • Electric field strength (V/m)

Limitations

  • Numerical simulation/modeling study (no human measurements reported in abstract)
  • Exposure scenario details (e.g.
  • phone position
  • power
  • distance) not provided in abstract
  • Only sub-6 GHz frequencies evaluated

Suggested hubs

  • 5g-policy (0.7)
    Study explicitly frames exposure as relevant to 5G sub-6 GHz applications and evaluates SAR in that context.
View raw extracted JSON
{
  "study_type": "engineering",
  "exposure": {
    "band": "RF",
    "source": "mobile phone",
    "frequency_mhz": null,
    "sar_wkg": 0.00014,
    "duration": null
  },
  "population": "Human head model (realistic numerical model)",
  "sample_size": null,
  "outcomes": [
    "Specific absorption rate (SAR) (10 g average tissue)",
    "Electric field strength (V/m)"
  ],
  "main_findings": "Numerical simulations (0.9, 1.8, 2.1, 2.45, 3.5, 5 GHz) of a realistic human head model with metal-framed spectacles, metallic implants, and/or earrings reported a maximum 10 g SAR of 14 × 10^-5 W/kg at 2.45 GHz in the model with earrings, and a highest electric field strength of 0.52 V/m at 1.8 GHz with all metal objects. The authors report that metal objects can increase SAR in external tissues and may act as shielding for deeper tissues, with values below international limits.",
  "effect_direction": "mixed",
  "limitations": [
    "Numerical simulation/modeling study (no human measurements reported in abstract)",
    "Exposure scenario details (e.g., phone position, power, distance) not provided in abstract",
    "Only sub-6 GHz frequencies evaluated"
  ],
  "evidence_strength": "low",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "sub-6 GHz",
    "5G",
    "SAR",
    "finite integration technique",
    "human head model",
    "spectacles",
    "dental implants",
    "earrings",
    "non-ionizing dosimetry"
  ],
  "suggested_hubs": [
    {
      "slug": "5g-policy",
      "weight": 0.55,
      "reason": "Study explicitly frames exposure as relevant to 5G sub-6 GHz applications and evaluates SAR in that context."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 467

Electromagnetic field exposure to human head model with various metal objects at sub-6 GHz frequencies · Non-native EMF