Share

Radio-frequency electromagnetic field (RF-EMF) exposure levels in different European outdoor urban environments in comparison with regulatory limits.

Damiano Urbinello, Wout Joseph, Anke Huss, Leen Verloock, Johan Beekhuizen, Roel Vermeulen, Luc Martens, Martin Röösli

PAPERpubmedEnvironment international2014exposure assessmentEffect: no_effectEvidence: Moderate

Abstract

BACKGROUND: Concerns of the general public about potential adverse health effects caused by radio-frequency electromagnetic fields (RF-EMFs) led authorities to introduce precautionary exposure limits, which vary considerably between regions. It may be speculated that precautionary limits affect the base station network in a manner that mean population exposure unintentionally increases. AIMS: The objectives of this multicentre study were to compare mean exposure levels in outdoor areas across four different European cities and to compare with regulatory RF-EMF exposure levels in the corresponding areas. METHODS: We performed measurements in the cities of Amsterdam (the Netherlands, regulatory limits for mobile phone base station frequency bands: 41-61 V/m), Basel (Switzerland, 4-6 V/m), Ghent (Belgium, 3-4.5 V/m) and Brussels (Belgium, 2.9-4.3 V/m) using a portable measurement device. Measurements were conducted in three different types of outdoor areas (central and non-central residential areas and downtown), between 2011 and 2012 at 12 different days. On each day, measurements were taken every 4s for approximately 15 to 30 min per area. Measurements per urban environment were repeated 12 times during 1 year. RESULTS: Arithmetic mean values for mobile phone base station exposure ranged between 0.22 V/m (Basel) and 0.41 V/m (Amsterdam) in all outdoor areas combined. The 95th percentile for total RF-EMF exposure varied between 0.46 V/m (Basel) and 0.82 V/m (Amsterdam) and the 99th percentile between 0.81 V/m (Basel) and 1.20 V/m (Brussels). CONCLUSIONS: All exposure levels were far below international reference levels proposed by ICNIRP (International Commission on Non-Ionizing Radiation Protection). Our study did not find indications that lowering the regulatory limit results in higher mobile phone base station exposure levels.

AI evidence extraction

At a glance
Study type
exposure assessment
Effect direction
no_effect
Population
—
Sample size
—
Exposure
RF mobile phone base station · Outdoor measurements (15–30 min per area), repeated 12 times over 1 year; measurements every 4 s on 12 days (2011–2012)
Evidence strength
Moderate
Confidence: 78% · Peer-reviewed: yes

Main findings

Across four European cities, arithmetic mean mobile phone base station exposure ranged from 0.22 V/m (Basel) to 0.41 V/m (Amsterdam) across all outdoor areas combined. The 95th percentile of total RF-EMF exposure ranged from 0.46 V/m (Basel) to 0.82 V/m (Amsterdam), and the 99th percentile from 0.81 V/m (Basel) to 1.20 V/m (Brussels). All measured exposure levels were far below ICNIRP international reference levels, and the study reports no indications that lower regulatory limits resulted in higher base station exposure levels.

Outcomes measured

  • Outdoor RF-EMF exposure levels (V/m) from mobile phone base stations
  • Total RF-EMF exposure percentiles (95th
  • 99th)
  • Comparison with regulatory limits and ICNIRP reference levels

Suggested hubs

  • who-icnirp (0.7)
    Compares measured outdoor RF-EMF levels to ICNIRP international reference levels and discusses regulatory limits.
View raw extracted JSON
{
  "study_type": "exposure_assessment",
  "exposure": {
    "band": "RF",
    "source": "mobile phone base station",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": "Outdoor measurements (15–30 min per area), repeated 12 times over 1 year; measurements every 4 s on 12 days (2011–2012)"
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "Outdoor RF-EMF exposure levels (V/m) from mobile phone base stations",
    "Total RF-EMF exposure percentiles (95th, 99th)",
    "Comparison with regulatory limits and ICNIRP reference levels"
  ],
  "main_findings": "Across four European cities, arithmetic mean mobile phone base station exposure ranged from 0.22 V/m (Basel) to 0.41 V/m (Amsterdam) across all outdoor areas combined. The 95th percentile of total RF-EMF exposure ranged from 0.46 V/m (Basel) to 0.82 V/m (Amsterdam), and the 99th percentile from 0.81 V/m (Basel) to 1.20 V/m (Brussels). All measured exposure levels were far below ICNIRP international reference levels, and the study reports no indications that lower regulatory limits resulted in higher base station exposure levels.",
  "effect_direction": "no_effect",
  "limitations": [],
  "evidence_strength": "moderate",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "RF-EMF",
    "radio-frequency electromagnetic fields",
    "exposure assessment",
    "outdoor urban environments",
    "mobile phone base stations",
    "regulatory limits",
    "ICNIRP",
    "Europe",
    "portable measurements",
    "V/m"
  ],
  "suggested_hubs": [
    {
      "slug": "who-icnirp",
      "weight": 0.6,
      "reason": "Compares measured outdoor RF-EMF levels to ICNIRP international reference levels and discusses regulatory limits."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 4694

Radio-frequency electromagnetic field (RF-EMF) exposure levels in different European outdoor urban environments in comparison with regulatory limits. · Non-native EMF