  "id": 4747,
  "url": "https://nnemf.org/research/4747-pentoxifylline-and-electromagnetic-field-improved-bone-fracture-healing",
  "title": "Pentoxifylline and electromagnetic field improved bone fracture healing in rats.",
  "authors": [
    "Yusuf Atalay",
    "Nedim Gunes",
    "Mehmet Dervis Guner",
    "Veysi Akpolat",
    "Mustafa Salih Celik",
    "Rezzan Guner"
  ],
  "journal": "Drug design, development and therapy",
  "year": "2015",
  "doi": "10.2147/dddt.s89669",
  "pmid": "26388687",
  "abstract": "BACKGROUND: The aim of this study was to evaluate the effects of a phosphodiesterase inhibitor pentoxifylline (PTX), electromagnetic fields (EMFs), and a mixture of both materials on bone fracture healing in a rat model. MATERIALS AND METHODS: Eighty male Wistar rats were randomly divided into four groups: Group A, femur fracture model with no treatment; Group B, femur fracture model treated with PTX 50 mg/kg/day intraperitoneal injection; Group C, femur fracture model treated with EMF 1.5±0.2 Mt/50 Hz/6 hours/day; and Group D, femur fracture model treated with PTX 50 mg/kg/day intraperitoneal injection and EMF 1.5±0.2 Mt/50 Hz/6 hours/day. RESULTS: Bone fracture healing was significantly better in Group B and Group C compared to Group A (P<0.05), but Group D did not show better bone fracture healing than Group A (P>0.05). CONCLUSION: It can be concluded that both a specific EMF and PTX had a positive effect on bone fracture healing but when used in combination, may not be beneficial.",
  "effect": "mixed",
  "evidence": "low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "mixed",
    "evidenceLabel": "Low",
    "population": "Male Wistar rats with femur fracture model",
    "sampleSize": "80",
    "exposure": "ELF · 0.05 MHz · 6 hours/day",
    "confidencePct": "86",
    "peerReviewed": "yes",
    "mainFindings": "In a rat femur fracture model, fracture healing was significantly better with pentoxifylline (50 mg/kg/day) or with EMF exposure (1.5±0.2 Mt, 50 Hz, 6 hours/day) compared with no treatment (P<0.05). The combined PTX+EMF group did not show better healing than no treatment (P>0.05).",
    "outcomes": [
      "Bone fracture healing"
    ],
    "limitations": [],
    "keywords": [
      "pentoxifylline",
      "electromagnetic field",
      "ELF",
      "50 Hz",
      "bone fracture healing",
      "rat model",
      "femur fracture"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": null,\n    \"frequency_mhz\": 0.05,\n    \"sar_wkg\": null,\n    \"duration\": \"6 hours/day\"\n  },\n  \"population\": \"Male Wistar rats with femur fracture model\",\n  \"sample_size\": 80,\n  \"outcomes\": [\n    \"Bone fracture healing\"\n  ],\n  \"main_findings\": \"In a rat femur fracture model, fracture healing was significantly better with pentoxifylline (50 mg/kg/day) or with EMF exposure (1.5±0.2 Mt, 50 Hz, 6 hours/day) compared with no treatment (P<0.05). The combined PTX+EMF group did not show better healing than no treatment (P>0.05).\",\n  \"effect_direction\": \"mixed\",\n  \"limitations\": [],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.86,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"pentoxifylline\",\n    \"electromagnetic field\",\n    \"ELF\",\n    \"50 Hz\",\n    \"bone fracture healing\",\n    \"rat model\",\n    \"femur fracture\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"elf-emf\",\n      \"weight\": 0.85,\n      \"reason\": \"Animal study using 50 Hz electromagnetic field exposure.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/26388687/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=4747",
  "updated": "2026-02-14 08:04:12"
}