{
  "id": 4787,
  "url": "https://nnemf.org/research/4787-protective-effect-of-10-hz-1-mt-electromagnetic",
  "title": "Protective Effect of 10-Hz, 1-mT Electromagnetic Field Exposure Against Hypoxia/Reoxygenation Injury in HK-2 Cells.",
  "authors": [
    "Soonho Lim",
    "Soo-Chan Kim",
    "Jae Young Kim"
  ],
  "journal": "Biomedical and environmental sciences : BES",
  "year": "2015",
  "doi": "10.3967/bes2015.032",
  "pmid": "25800450",
  "abstract": "We investigated the protective effects of electromagnetic field (EMF) on the survival of the human renal proximal tubular cell line, HK-2, using an in vitro hypoxia/reoxygenation (H/R) injury model. The survival rate of cells cultured under H/R condition declined significantly, while the intracellular reactive oxygen species (ROS) levels markedly increased. The 10 Hz/1 mT EMF exposure reversed the H/R induced reduction in cell survival and induction of intracellular ROS. Our results suggest that 10 Hz/1 mT EMF exposure could inhibit H/R-induced cell death of HK-2 via suppression of intracellular ROS production and that this treatment might be clinically useful for the amelioration of renal ischemia/reperfusion injury.",
  "effect": "benefit",
  "evidence": "low",
  "extraction": {
    "studyType": "in_vitro",
    "studyTypeLabel": "In vitro study",
    "effectDirection": "benefit",
    "evidenceLabel": "Low",
    "population": "Human renal proximal tubular cell line (HK-2)",
    "sampleSize": "—",
    "exposure": "ELF · 0.01 MHz",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "In an in vitro hypoxia/reoxygenation injury model using HK-2 cells, 10 Hz/1 mT EMF exposure reversed the H/R-induced reduction in cell survival and reduced the H/R-associated increase in intracellular ROS.",
    "outcomes": [
      "Cell survival rate under hypoxia/reoxygenation (H/R) injury conditions",
      "Intracellular reactive oxygen species (ROS) levels",
      "H/R-induced cell death (inferred from survival/cell death wording)"
    ],
    "limitations": [
      "In vitro cell-line study",
      "clinical relevance not established in the abstract",
      "Exposure duration not reported in the abstract",
      "Sample size and replication details not reported in the abstract"
    ],
    "keywords": [
      "electromagnetic field",
      "ELF-EMF",
      "10 Hz",
      "1 mT",
      "HK-2 cells",
      "hypoxia/reoxygenation",
      "ischemia/reperfusion",
      "reactive oxygen species",
      "cell survival"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"in_vitro\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": null,\n    \"frequency_mhz\": 0.01,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": \"Human renal proximal tubular cell line (HK-2)\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Cell survival rate under hypoxia/reoxygenation (H/R) injury conditions\",\n    \"Intracellular reactive oxygen species (ROS) levels\",\n    \"H/R-induced cell death (inferred from survival/cell death wording)\"\n  ],\n  \"main_findings\": \"In an in vitro hypoxia/reoxygenation injury model using HK-2 cells, 10 Hz/1 mT EMF exposure reversed the H/R-induced reduction in cell survival and reduced the H/R-associated increase in intracellular ROS.\",\n  \"effect_direction\": \"benefit\",\n  \"limitations\": [\n    \"In vitro cell-line study; clinical relevance not established in the abstract\",\n    \"Exposure duration not reported in the abstract\",\n    \"Sample size and replication details not reported in the abstract\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"electromagnetic field\",\n    \"ELF-EMF\",\n    \"10 Hz\",\n    \"1 mT\",\n    \"HK-2 cells\",\n    \"hypoxia/reoxygenation\",\n    \"ischemia/reperfusion\",\n    \"reactive oxygen species\",\n    \"cell survival\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/25800450/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=4787",
  "updated": "2026-02-14 08:04:44"
}