  "id": 4790,
  "url": "https://nnemf.org/research/4790-impact-of-a-small-cell-on-the-rf",
  "title": "Impact of a small cell on the RF-EMF exposure in a train.",
  "authors": [
    "Sam Aerts",
    "David Plets",
    "Arno Thielens",
    "Luc Martens",
    "Wout Joseph"
  ],
  "journal": "International journal of environmental research and public health",
  "year": "2015",
  "doi": "10.3390/ijerph120302639",
  "pmid": "25734793",
  "abstract": "The deployment of a miniature mobile-phone base station or small cell in a train car significantly improves the coverage and the capacity of a mobile network service on the train. However, the impact of the small cell on the passengers' exposure to radio-frequency electromagnetic fields (RF-EMF) is unknown. In this study, we assessed experimentally the RF-EMF exposure of a mobile-phone user who is either connected to the outdoor macrocell network or to an in-train small cell, while traveling on the train, by means of the absorbed-dose concept, which combines the base station downlink exposure with the mobile-phone uplink exposure. For Global System for Mobile Communications (GSM) technology at 1800 MHz, we found that by connecting to a small cell, the brain exposure of the user could realistically be reduced by a factor 35 and the whole-body exposure by a factor 11.",
  "effect": "benefit",
  "evidence": "low",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "benefit",
    "evidenceLabel": "Low",
    "population": "mobile-phone user traveling on a train (passenger)",
    "sampleSize": "—",
    "exposure": "RF in-train small cell (miniature mobile-phone base station) vs outdoor macrocell network; mobile phone user uplink + base station downlink · 1800 MHz · while traveling on the train",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "For GSM at 1800 MHz, connecting to an in-train small cell (vs outdoor macrocell) could realistically reduce the user’s brain exposure by a factor of 35 and whole-body exposure by a factor of 11, using an absorbed-dose concept combining downlink and uplink contributions.",
    "outcomes": [
      "RF-EMF absorbed dose (combined downlink + uplink)",
      "brain exposure",
      "whole-body exposure"
    ],
    "limitations": [],
    "keywords": [
      "small cell",
      "train",
      "RF-EMF",
      "exposure assessment",
      "absorbed dose",
      "downlink",
      "uplink",
      "GSM",
      "1800 MHz"
    ],
    "hubs": [
      {
        "slug": "5g-policy",
        "weight": "0.7",
        "reason": "Study concerns small cells, but only GSM 1800 MHz is specified (not 5G)."
      },
      {
        "slug": "who-icnirp",
        "weight": "0.7",
        "reason": "RF-EMF exposure assessment relevant to guideline/policy discussions, though no guidelines are evaluated."
      }
    ],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"in-train small cell (miniature mobile-phone base station) vs outdoor macrocell network; mobile phone user uplink + base station downlink\",\n    \"frequency_mhz\": 1800,\n    \"sar_wkg\": null,\n    \"duration\": \"while traveling on the train\"\n  },\n  \"population\": \"mobile-phone user traveling on a train (passenger)\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"RF-EMF absorbed dose (combined downlink + uplink)\",\n    \"brain exposure\",\n    \"whole-body exposure\"\n  ],\n  \"main_findings\": \"For GSM at 1800 MHz, connecting to an in-train small cell (vs outdoor macrocell) could realistically reduce the user’s brain exposure by a factor of 35 and whole-body exposure by a factor of 11, using an absorbed-dose concept combining downlink and uplink contributions.\",\n  \"effect_direction\": \"benefit\",\n  \"limitations\": [],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"small cell\",\n    \"train\",\n    \"RF-EMF\",\n    \"exposure assessment\",\n    \"absorbed dose\",\n    \"downlink\",\n    \"uplink\",\n    \"GSM\",\n    \"1800 MHz\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"5g-policy\",\n      \"weight\": 0.2,\n      \"reason\": \"Study concerns small cells, but only GSM 1800 MHz is specified (not 5G).\"\n    },\n    {\n      \"slug\": \"who-icnirp\",\n      \"weight\": 0.15,\n      \"reason\": \"RF-EMF exposure assessment relevant to guideline/policy discussions, though no guidelines are evaluated.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/25734793/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=4790",
  "updated": "2026-02-14 08:04:46"
}