{
  "id": 4829,
  "url": "https://nnemf.org/research/4829-a-short-term-extremely-low-frequency-electromagnetic-field",
  "title": "A short-term extremely low frequency electromagnetic field exposure increases circulating leukocyte numbers and affects HPA-axis signaling in mice.",
  "authors": [
    "Stan de Kleijn",
    "Gerben Ferwerda",
    "Michelle Wiese",
    "Jos Trentelman",
    "Jan Cuppen",
    "Tamas Kozicz",
    "Linda de Jager",
    "Peter W M Hermans",
    "B M Lidy Verburg-van Kemenade"
  ],
  "journal": "Bioelectromagnetics",
  "year": "2016",
  "doi": "10.1002/bem.21998",
  "pmid": "27553635",
  "abstract": "There is still uncertainty whether extremely low frequency electromagnetic fields (ELF-EMF) can induce health effects like immunomodulation. Despite evidence obtained in vitro, an unambiguous association has not yet been established in vivo. Here, mice were exposed to ELF-EMF for 1, 4, and 24 h/day in a short-term (1 week) and long-term (15 weeks) set-up to investigate whole body effects on the level of stress regulation and immune response. ELF-EMF signal contained multiple frequencies (20-5000 Hz) and a magnetic flux density of 10 μT. After exposure, blood was analyzed for leukocyte numbers (short-term and long-term) and adrenocorticotropic hormone concentration (short-term only). Furthermore, in the short-term experiment, stress-related parameters, corticotropin-releasing hormone, proopiomelanocortin (POMC) and CYP11A1 gene-expression, respectively, were determined in the hypothalamic paraventricular nucleus, pituitary, and adrenal glands. In the short-term but not long-term experiment, leukocyte counts were significantly higher in the 24 h-exposed group compared with controls, mainly represented by increased neutrophils and CD4 ± lymphocytes. POMC expression and plasma adrenocorticotropic hormone were significantly lower compared with unexposed control mice. In conclusion, short-term ELF-EMF exposure may affect hypothalamic-pituitary-adrenal axis activation in mice. Changes in stress hormone release may explain changes in circulating leukocyte numbers and composition. Bioelectromagnetics. 37:433-443, 2016.",
  "effect": "mixed",
  "evidence": "low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "mixed",
    "evidenceLabel": "Low",
    "population": "Mice",
    "sampleSize": "—",
    "exposure": "ELF · 1, 4, or 24 h/day; short-term 1 week and long-term 15 weeks",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "ELF-EMF exposure (20–5000 Hz; 10 μT) increased leukocyte counts in the short-term experiment for the 24 h/day exposed group versus controls, mainly due to increased neutrophils and CD4± lymphocytes; this was not observed in the long-term experiment. In the short-term experiment, POMC expression and plasma ACTH were significantly lower than in unexposed controls.",
    "outcomes": [
      "Circulating leukocyte counts and composition (neutrophils",
      "CD4± lymphocytes)",
      "Plasma adrenocorticotropic hormone (ACTH) concentration",
      "Stress-related gene expression: corticotropin-releasing hormone (hypothalamic PVN)",
      "proopiomelanocortin (POMC",
      "pituitary)",
      "CYP11A1 (adrenal glands)"
    ],
    "limitations": [
      "Sample size not reported in provided abstract/metadata",
      "Exposure source and detailed dosimetry beyond frequency range and magnetic flux density not described in provided abstract/metadata",
      "ACTH measured in short-term experiment only",
      "Findings differed between short-term and long-term setups (effect not observed long-term)"
    ],
    "keywords": [
      "extremely low frequency",
      "ELF-EMF",
      "20-5000 Hz",
      "10 μT",
      "mice",
      "leukocytes",
      "neutrophils",
      "CD4 lymphocytes",
      "HPA axis",
      "ACTH",
      "POMC",
      "stress regulation",
      "immune response"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "ELF-EMF exposure relevant to ELF contexts, but no specific occupational setting stated."
      }
    ],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": null,\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"1, 4, or 24 h/day; short-term 1 week and long-term 15 weeks\"\n  },\n  \"population\": \"Mice\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Circulating leukocyte counts and composition (neutrophils, CD4± lymphocytes)\",\n    \"Plasma adrenocorticotropic hormone (ACTH) concentration\",\n    \"Stress-related gene expression: corticotropin-releasing hormone (hypothalamic PVN), proopiomelanocortin (POMC; pituitary), CYP11A1 (adrenal glands)\"\n  ],\n  \"main_findings\": \"ELF-EMF exposure (20–5000 Hz; 10 μT) increased leukocyte counts in the short-term experiment for the 24 h/day exposed group versus controls, mainly due to increased neutrophils and CD4± lymphocytes; this was not observed in the long-term experiment. In the short-term experiment, POMC expression and plasma ACTH were significantly lower than in unexposed controls.\",\n  \"effect_direction\": \"mixed\",\n  \"limitations\": [\n    \"Sample size not reported in provided abstract/metadata\",\n    \"Exposure source and detailed dosimetry beyond frequency range and magnetic flux density not described in provided abstract/metadata\",\n    \"ACTH measured in short-term experiment only\",\n    \"Findings differed between short-term and long-term setups (effect not observed long-term)\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"extremely low frequency\",\n    \"ELF-EMF\",\n    \"20-5000 Hz\",\n    \"10 μT\",\n    \"mice\",\n    \"leukocytes\",\n    \"neutrophils\",\n    \"CD4 lymphocytes\",\n    \"HPA axis\",\n    \"ACTH\",\n    \"POMC\",\n    \"stress regulation\",\n    \"immune response\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.2,\n      \"reason\": \"ELF-EMF exposure relevant to ELF contexts, but no specific occupational setting stated.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/27553635/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=4829",
  "updated": "2026-02-14 08:06:41"
}