  "title": "Monitoring of people and workers exposure to the electric, magnetic and electromagnetic fields in an Italian National Cancer Institute.",
  "authors": [
    "Anna Maria Di Nallo",
    "Lidia Strigari",
    "Claudia Giliberti",
    "Angelico Bedini",
    "Raffaele Palomba",
    "Marcello Benassi"
  ],
  "journal": "Journal of experimental & clinical cancer research : CR",
  "year": "2008",
  "doi": "10.1186/1756-9966-27-16",
  "pmid": "18598357",
  "abstract": "BACKGROUND: The paper reports the electric, magnetic and electromagnetic fields (emf) measurements carried out in the Regina Elena National Cancer Institute (NCI). Several devices, used in diagnostics and in medical cures, can represent sources of emf for the workers and for the public subjected to the treatments. The aim is to evaluate their exposition, in order to assess the compliance with the law. METHODS: The investigations have been carried out in the departments of: intensive care, physiotherapy, MR presstherapy and in the surgical rooms. The measurements have been performed using broad band probes in the frequency ranges 5 Hz/30 kHz and 100 kHz-3 GHz. RESULTS: The variability of the magnetic induction (B(microT)) levels is between 0,05 microT and 80 microT. The statistical distribution shows that most of the measurements are in the range 0,05<B = 0,5 microT and the 89% of the B(microT) levels are within the 3 microT. CONCLUSION: The measurement of the emf levels in the NCI is recommended because of the presence of the oncological patients; their long stay near the equipments and their day-long exposure represent additional risk factors for which a prudent avoidance strategy have to de adopted.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "Workers and patients/public in an Italian National Cancer Institute (departments: intensive care, physiotherapy, MR presstherapy, surgical rooms)",
    "sampleSize": "—",
    "exposure": "ELF 1000–3000 MHz",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "Magnetic induction (B) measurements ranged from 0.05 to 80 microT. Most measurements were between 0.05 and 0.5 microT, and 89% of B levels were within 3 microT.",
    "outcomes": [
      "Measured electric",
      "magnetic and electromagnetic field levels (magnetic induction B in microtesla)",
      "Compliance assessment with legal limits (as stated aim)"
    ],
    "limitations": [
      "Sample size/number of measurements not reported in abstract",
      "Electric-field and RF results not quantified in abstract (only magnetic induction B reported)",
      "No explicit statement of compliance outcomes in results section"
    ],
    "keywords": [
      "electric fields",
      "magnetic fields",
      "electromagnetic fields",
      "exposure assessment",
      "hospital",
      "medical devices",
      "workers",
      "patients",
      "broadband probes",
      "5 Hz-30 kHz",
      "100 kHz-3 GHz",
      "magnetic induction",
      "microtesla"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Measurements assess EMF exposure for workers in hospital departments."
      }
    ],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": \"ELF to RF\",\n    \"source\": \"hospital/medical equipment (diagnostics and treatments)\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": \"Workers and patients/public in an Italian National Cancer Institute (departments: intensive care, physiotherapy, MR presstherapy, surgical rooms)\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Measured electric, magnetic and electromagnetic field levels (magnetic induction B in microtesla)\",\n    \"Compliance assessment with legal limits (as stated aim)\"\n  ],\n  \"main_findings\": \"Magnetic induction (B) measurements ranged from 0.05 to 80 microT. Most measurements were between 0.05 and 0.5 microT, and 89% of B levels were within 3 microT.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"Sample size/number of measurements not reported in abstract\",\n    \"Electric-field and RF results not quantified in abstract (only magnetic induction B reported)\",\n    \"No explicit statement of compliance outcomes in results section\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"electric fields\",\n    \"magnetic fields\",\n    \"electromagnetic fields\",\n    \"exposure assessment\",\n    \"hospital\",\n    \"medical devices\",\n    \"workers\",\n    \"patients\",\n    \"broadband probes\",\n    \"5 Hz-30 kHz\",\n    \"100 kHz-3 GHz\",\n    \"magnetic induction\",\n    \"microtesla\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.78,\n      \"reason\": \"Measurements assess EMF exposure for workers in hospital departments.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/18598357/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=5006",
  "updated": "2026-02-14 08:11:36"
}