Share

Effects of subchronic exposure to a 1439 MHz electromagnetic field on the microcirculatory parameters in rat brain.

Hiroshi Masuda, Akira Ushiyama, Shogo Hirota, Kanako Wake, Soichi Watanabe, Yukio Yamanaka, Masao Taki, Chiyoji Ohkubo

PAPERpubmedIn vivo (Athens, Greece)2007Animal studyEffect: no_effectEvidence: Low

Abstract

UNLABELLED: THE AIM of this study was to investigate whether repeated exposure to radio frequency electromagnetic field (RF-EMF) of 1439 MHz affects the cerebral microcirculation, including blood-brain barrier function, in a rat brain. MATERIALS AND METHODS: The head of the rat was exposed for four weeks (60 min/day, 5 days/week) to RF-EMF at 2.4 W/kg of brain averaged specific absorption rate (BASAR). Three microcirculatory parameters: blood-brain barrier permeability, leukocyte behavior and plasma velocity were measured before and after RF-EMF exposure using a closed cranial window method. RESULTS: No extravasation of intravenously injected dyes from pial venules was found at any BASAR level. No significant changes in the number of endothelial-adhering leukocytes after exposure were found. The plasma velocity remained constant within the physiological range through each exposure. CONCLUSION: These findings suggest that there were no effects on the cerebral microcirculation under the given RF-EMF exposure conditions.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
no_effect
Population
Rats
Sample size
—
Exposure
RF · 1439 MHz · 2.4 W/kg · 4 weeks (60 min/day, 5 days/week)
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

After 4 weeks of head exposure to 1439 MHz RF-EMF at 2.4 W/kg brain-averaged SAR, no dye extravasation from pial venules was observed, no significant changes in endothelial-adhering leukocytes were found, and plasma velocity remained within the physiological range.

Outcomes measured

  • Cerebral microcirculation parameters
  • Blood-brain barrier permeability (dye extravasation)
  • Leukocyte behavior (endothelial-adhering leukocytes)
  • Plasma velocity

Limitations

  • Sample size not reported in abstract
  • Only one exposure frequency and SAR level described in abstract
  • Outcomes limited to selected microcirculatory parameters measured with a closed cranial window method
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "RF",
    "source": null,
    "frequency_mhz": 1439,
    "sar_wkg": 2.4,
    "duration": "4 weeks (60 min/day, 5 days/week)"
  },
  "population": "Rats",
  "sample_size": null,
  "outcomes": [
    "Cerebral microcirculation parameters",
    "Blood-brain barrier permeability (dye extravasation)",
    "Leukocyte behavior (endothelial-adhering leukocytes)",
    "Plasma velocity"
  ],
  "main_findings": "After 4 weeks of head exposure to 1439 MHz RF-EMF at 2.4 W/kg brain-averaged SAR, no dye extravasation from pial venules was observed, no significant changes in endothelial-adhering leukocytes were found, and plasma velocity remained within the physiological range.",
  "effect_direction": "no_effect",
  "limitations": [
    "Sample size not reported in abstract",
    "Only one exposure frequency and SAR level described in abstract",
    "Outcomes limited to selected microcirculatory parameters measured with a closed cranial window method"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "1439 MHz",
    "RF-EMF",
    "radiofrequency",
    "rat brain",
    "cerebral microcirculation",
    "blood-brain barrier",
    "leukocytes",
    "plasma velocity",
    "specific absorption rate",
    "closed cranial window"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 5051

Effects of subchronic exposure to a 1439 MHz electromagnetic field on the microcirculatory parameters in rat brain. · Non-native EMF