Share

Acute exposure to low-level CW and GSM-modulated 900 MHz radiofrequency does not affect Ba 2+ currents through voltage-gated calcium channels in rat cortical neurons.

Daniela Platano, Pietro Mesirca, Alessandra Paffi, Monica Pellegrino, Micaela Liberti, Francesca Apollonio, Ferdinando Bersani, Giorgio Aicardi

PAPERpubmedBioelectromagnetics2007In vitro studyEffect: no_effectEvidence: Low

Abstract

We have studied the non-thermal effects of radiofrequency (RF) electromagnetic fields (EMFs) on Ba(2+) currents (I Ba 2+) through voltage-gated calcium channels (VGCC), recorded in primary cultures of rat cortical neurons using the patch-clamp technique. To assess whether low-level acute RF field exposure could modify the amplitude and/or the voltage-dependence of I Ba 2+, Petri dishes containing cultured neurons were exposed for 1-3 periods of 90 s to 900 MHz RF-EMF continuous wave (CW) or amplitude-modulated according to global system mobile communication standard (GSM) during whole-cell recording. The specific absorption rates (SARs) were 2 W/kg for CW and 2 W/kg (time average value) for GSM-modulated signals, respectively. The results obtained indicate that single or multiple acute exposures to either CW or GSM-modulated 900 MHz RF-EMFs do not significantly alter the current amplitude or the current-voltage relationship of I Ba 2+, through VGCC.

AI evidence extraction

At a glance
Study type
In vitro study
Effect direction
no_effect
Population
Primary cultures of rat cortical neurons
Sample size
—
Exposure
RF · 900 MHz · 2 W/kg · 1–3 periods of 90 s (acute)
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

In patch-clamp recordings from primary cultures of rat cortical neurons, acute exposure (1–3 × 90 s) to 900 MHz RF-EMF (CW or GSM-modulated) at SAR 2 W/kg did not significantly change Ba2+ current amplitude or the current–voltage relationship through VGCC.

Outcomes measured

  • Ba2+ currents (IBa2+) through voltage-gated calcium channels (VGCC)
  • Current amplitude
  • Current–voltage relationship (voltage-dependence)

Limitations

  • In vitro primary neuron culture model (not in vivo)
  • Acute exposure only (1–3 × 90 s)
  • Sample size not reported in abstract
View raw extracted JSON
{
  "study_type": "in_vitro",
  "exposure": {
    "band": "RF",
    "source": null,
    "frequency_mhz": 900,
    "sar_wkg": 2,
    "duration": "1–3 periods of 90 s (acute)"
  },
  "population": "Primary cultures of rat cortical neurons",
  "sample_size": null,
  "outcomes": [
    "Ba2+ currents (IBa2+) through voltage-gated calcium channels (VGCC)",
    "Current amplitude",
    "Current–voltage relationship (voltage-dependence)"
  ],
  "main_findings": "In patch-clamp recordings from primary cultures of rat cortical neurons, acute exposure (1–3 × 90 s) to 900 MHz RF-EMF (CW or GSM-modulated) at SAR 2 W/kg did not significantly change Ba2+ current amplitude or the current–voltage relationship through VGCC.",
  "effect_direction": "no_effect",
  "limitations": [
    "In vitro primary neuron culture model (not in vivo)",
    "Acute exposure only (1–3 × 90 s)",
    "Sample size not reported in abstract"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "radiofrequency",
    "900 MHz",
    "GSM modulation",
    "continuous wave",
    "SAR 2 W/kg",
    "patch clamp",
    "rat cortical neurons",
    "voltage-gated calcium channels",
    "Ba2+ currents",
    "non-thermal effects"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 5058

Acute exposure to low-level CW and GSM-modulated 900 MHz radiofrequency does not affect Ba 2+ currents through voltage-gated calcium channels in rat cortical neurons. · Non-native EMF