Personal digital assistant (PDA) cell phone units produce elevated extremely-low frequency electromagnetic field emissions.

Cindy Sage, Olle Johansson, S Amy Sage

PAPERpubmedBioelectromagnetics2007exposure assessmentEffect: unclearEvidence: Insufficient

Abstract

Initial tests indicate that personal and occupational use of personal digital assistants (PDAs or palm-held wireless units) produce high intensity bursts of extremely-low frequency electromagnetic fields (ELF-EMF). These emissions could result in comparatively high ELF-EMF exposure in persons that carry a PDA close to the body (i.e., in a pocket or on a belt); or held to the head for cell phone conversations. ELF-EMF emissions of 10 microT were recorded on PDAs during normal office use over a 24 h test period. Results of ELF-EMF measurements show that email transmit and receive functions produce rapid, short-duration ELF-EMF spikes in the 2-10 microT range, each lasting several seconds to over a minute apparently depending on file download size. Some units produced spikes as high as 30-60 microT during email activities. Cell phone activity on PDAs produced continuously elevated ELF-EMF readings in the 0.5-1 microT range, as opposed to the rapid spiking pattern for email receipt and transmission. Switching the PDA unit from "OFF" to "ON" position resulted in single ELF-EMF pulses of over 90 microT on two units. Email downloads into the PDA can occur randomly throughout the day and night when the unit is "ON"; thus the user who wears the PDA may be receiving high-intensity ELF-EMF pulses throughout the day and night. The frequency of email traffic on the PDA, and the power switching unit (battery unit) may affect the frequency and intensity of ELF-EMF emissions.

AI evidence extraction

At a glance
Study type
exposure assessment
Effect direction
unclear
Population
—
Sample size
—
Exposure
ELF personal digital assistant (PDA) / palm-held wireless unit with cell phone and email functions · 24 h test period; spikes lasting several seconds to over a minute
Evidence strength
Insufficient
Confidence: 74% · Peer-reviewed: yes

Main findings

ELF-EMF emissions up to 10 microT were recorded on PDAs during normal office use over a 24 h period. Email transmit/receive produced rapid short-duration spikes in the 2–10 microT range, with some units producing spikes as high as 30–60 microT; switching from OFF to ON produced single pulses over 90 microT on two units. Cell phone activity produced continuously elevated readings in the 0.5–1 microT range.

Outcomes measured

  • ELF-EMF emission levels (microT) during PDA normal office use
  • ELF-EMF spikes during email transmit/receive
  • ELF-EMF levels during cell phone activity
  • ELF-EMF pulses when switching from OFF to ON

Limitations

  • Population and health outcomes were not assessed (emissions/exposure characterization only).
  • Sample size and number of PDA units tested are not reported in the abstract.
  • Measurement methods/instrumentation and exact frequency characteristics are not described in the abstract.

Suggested hubs

  • occupational-exposure (0.7)
    Abstract mentions personal and occupational use and measurements during normal office use.
View raw extracted JSON
{
  "study_type": "exposure_assessment",
  "exposure": {
    "band": "ELF",
    "source": "personal digital assistant (PDA) / palm-held wireless unit with cell phone and email functions",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": "24 h test period; spikes lasting several seconds to over a minute"
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "ELF-EMF emission levels (microT) during PDA normal office use",
    "ELF-EMF spikes during email transmit/receive",
    "ELF-EMF levels during cell phone activity",
    "ELF-EMF pulses when switching from OFF to ON"
  ],
  "main_findings": "ELF-EMF emissions up to 10 microT were recorded on PDAs during normal office use over a 24 h period. Email transmit/receive produced rapid short-duration spikes in the 2–10 microT range, with some units producing spikes as high as 30–60 microT; switching from OFF to ON produced single pulses over 90 microT on two units. Cell phone activity produced continuously elevated readings in the 0.5–1 microT range.",
  "effect_direction": "unclear",
  "limitations": [
    "Population and health outcomes were not assessed (emissions/exposure characterization only).",
    "Sample size and number of PDA units tested are not reported in the abstract.",
    "Measurement methods/instrumentation and exact frequency characteristics are not described in the abstract."
  ],
  "evidence_strength": "insufficient",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "PDA",
    "personal digital assistant",
    "palm-held wireless unit",
    "ELF-EMF",
    "extremely-low frequency",
    "microtesla",
    "email transmit",
    "email receive",
    "cell phone activity",
    "power switching",
    "battery unit",
    "exposure assessment"
  ],
  "suggested_hubs": [
    {
      "slug": "occupational-exposure",
      "weight": 0.42,
      "reason": "Abstract mentions personal and occupational use and measurements during normal office use."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 5073

Personal digital assistant (PDA) cell phone units produce elevated extremely-low frequency electromagnetic field emissions. · Non-native EMF