  "id": 5073,
  "url": "https://nnemf.org/research/5073-personal-digital-assistant-pda-cell-phone-units-produce",
  "title": "Personal digital assistant (PDA) cell phone units produce elevated extremely-low frequency electromagnetic field emissions.",
  "authors": [
    "Cindy Sage",
    "Olle Johansson",
    "S Amy Sage"
  ],
  "journal": "Bioelectromagnetics",
  "year": "2007",
  "doi": "10.1002/bem.20315",
  "pmid": "17357117",
  "abstract": "Initial tests indicate that personal and occupational use of personal digital assistants (PDAs or palm-held wireless units) produce high intensity bursts of extremely-low frequency electromagnetic fields (ELF-EMF). These emissions could result in comparatively high ELF-EMF exposure in persons that carry a PDA close to the body (i.e., in a pocket or on a belt); or held to the head for cell phone conversations. ELF-EMF emissions of 10 microT were recorded on PDAs during normal office use over a 24 h test period. Results of ELF-EMF measurements show that email transmit and receive functions produce rapid, short-duration ELF-EMF spikes in the 2-10 microT range, each lasting several seconds to over a minute apparently depending on file download size. Some units produced spikes as high as 30-60 microT during email activities. Cell phone activity on PDAs produced continuously elevated ELF-EMF readings in the 0.5-1 microT range, as opposed to the rapid spiking pattern for email receipt and transmission. Switching the PDA unit from \"OFF\" to \"ON\" position resulted in single ELF-EMF pulses of over 90 microT on two units. Email downloads into the PDA can occur randomly throughout the day and night when the unit is \"ON\"; thus the user who wears the PDA may be receiving high-intensity ELF-EMF pulses throughout the day and night. The frequency of email traffic on the PDA, and the power switching unit (battery unit) may affect the frequency and intensity of ELF-EMF emissions.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "ELF personal digital assistant (PDA) / palm-held wireless unit with cell phone and email functions · 24 h test period; spikes lasting several seconds to over a minute",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "ELF-EMF emissions up to 10 microT were recorded on PDAs during normal office use over a 24 h period. Email transmit/receive produced rapid short-duration spikes in the 2–10 microT range, with some units producing spikes as high as 30–60 microT; switching from OFF to ON produced single pulses over 90 microT on two units. Cell phone activity produced continuously elevated readings in the 0.5–1 microT range.",
    "outcomes": [
      "ELF-EMF emission levels (microT) during PDA normal office use",
      "ELF-EMF spikes during email transmit/receive",
      "ELF-EMF levels during cell phone activity",
      "ELF-EMF pulses when switching from OFF to ON"
    ],
    "limitations": [
      "Population and health outcomes were not assessed (emissions/exposure characterization only).",
      "Sample size and number of PDA units tested are not reported in the abstract.",
      "Measurement methods/instrumentation and exact frequency characteristics are not described in the abstract."
    ],
    "keywords": [
      "PDA",
      "personal digital assistant",
      "palm-held wireless unit",
      "ELF-EMF",
      "extremely-low frequency",
      "microtesla",
      "email transmit",
      "email receive",
      "cell phone activity",
      "power switching",
      "battery unit",
      "exposure assessment"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Abstract mentions personal and occupational use and measurements during normal office use."
      }
    ],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": \"personal digital assistant (PDA) / palm-held wireless unit with cell phone and email functions\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"24 h test period; spikes lasting several seconds to over a minute\"\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"ELF-EMF emission levels (microT) during PDA normal office use\",\n    \"ELF-EMF spikes during email transmit/receive\",\n    \"ELF-EMF levels during cell phone activity\",\n    \"ELF-EMF pulses when switching from OFF to ON\"\n  ],\n  \"main_findings\": \"ELF-EMF emissions up to 10 microT were recorded on PDAs during normal office use over a 24 h period. Email transmit/receive produced rapid short-duration spikes in the 2–10 microT range, with some units producing spikes as high as 30–60 microT; switching from OFF to ON produced single pulses over 90 microT on two units. Cell phone activity produced continuously elevated readings in the 0.5–1 microT range.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"Population and health outcomes were not assessed (emissions/exposure characterization only).\",\n    \"Sample size and number of PDA units tested are not reported in the abstract.\",\n    \"Measurement methods/instrumentation and exact frequency characteristics are not described in the abstract.\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"PDA\",\n    \"personal digital assistant\",\n    \"palm-held wireless unit\",\n    \"ELF-EMF\",\n    \"extremely-low frequency\",\n    \"microtesla\",\n    \"email transmit\",\n    \"email receive\",\n    \"cell phone activity\",\n    \"power switching\",\n    \"battery unit\",\n    \"exposure assessment\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.42,\n      \"reason\": \"Abstract mentions personal and occupational use and measurements during normal office use.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/17357117/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=5073",
  "updated": "2026-02-14 08:13:12"
}