  "id": 5076,
  "url": "https://nnemf.org/research/5076-electromagnetic-field-treatment-of-nerve-crush-injury-in",
  "title": "Electromagnetic field treatment of nerve crush injury in a rat model: effect of signal configuration on functional recovery.",
  "authors": [
    "Janet L Walker",
    "Richard Kryscio",
    "Jennifer Smith",
    "Arthur Pilla",
    "Betty F Sisken"
  ],
  "journal": "Bioelectromagnetics",
  "year": "2007",
  "doi": "10.1002/bem.20302",
  "pmid": "17265446",
  "abstract": "Electromagnetic fields (EMFs) have been demonstrated to enhance mammalian peripheral nerve regeneration in vitro and in vivo. Using an EMF signal shown to enhance neurite outgrowth in vitro, we tested this field in vivo using three different amplitudes. The rat sciatic nerve was crushed. Whole body exposure was performed for 4 h/day for 5 days in a 96-turn solenoid coil controlled by a signal generator and power amplifier. The induced electric field at the target tissue consisted of a bipolar rectangular pulse, having 1 and 0.3 ms durations in each polarity, respectively. Pulse repetition rate was 2 per second. By varying the current, the coils produced fields consisting of sham (no current) and peak magnetic fields of 0.03 mT, 0.3 mT, and 3 mT, corresponding to peak induced electric fields of 1, 10, and 100 microV/cm, respectively, at the tissue target. Walking function was assessed over 43 days using video recording and measurement of the 1-5 toe-spread, using an imaging program. Comparing injured to uninjured hind limbs, mean responses were evaluated using a linear mixed statistical model. There was no difference found in recovery of the toe-spread function between any EMF treatments compared to sham.",
  "effect": "no_effect",
  "evidence": "low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "no_effect",
    "evidenceLabel": "Low",
    "population": "Rats (sciatic nerve crush injury model)",
    "sampleSize": "—",
    "exposure": "ELF other · 4 h/day for 5 days",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "In a rat sciatic nerve crush model with whole-body EMF exposure (bipolar rectangular pulses; 2 pulses/second) at peak magnetic fields of 0.03, 0.3, or 3 mT (vs sham), there was no difference in recovery of toe-spread function compared with sham over 43 days.",
    "outcomes": [
      "Peripheral nerve functional recovery (walking function)",
      "Toe-spread (1-5) recovery over 43 days"
    ],
    "limitations": [
      "Sample size not reported in the provided abstract/metadata",
      "Outcome assessment described for toe-spread/walking function",
      "other potential regeneration endpoints not reported in the provided abstract",
      "Exposure described as whole-body",
      "tissue-specific dosimetry beyond induced electric field estimates not detailed in the provided abstract"
    ],
    "keywords": [
      "electromagnetic fields",
      "ELF",
      "bipolar rectangular pulse",
      "solenoid coil",
      "whole-body exposure",
      "sciatic nerve crush",
      "peripheral nerve regeneration",
      "toe-spread",
      "walking function",
      "rat model"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": \"other\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"4 h/day for 5 days\"\n  },\n  \"population\": \"Rats (sciatic nerve crush injury model)\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Peripheral nerve functional recovery (walking function)\",\n    \"Toe-spread (1-5) recovery over 43 days\"\n  ],\n  \"main_findings\": \"In a rat sciatic nerve crush model with whole-body EMF exposure (bipolar rectangular pulses; 2 pulses/second) at peak magnetic fields of 0.03, 0.3, or 3 mT (vs sham), there was no difference in recovery of toe-spread function compared with sham over 43 days.\",\n  \"effect_direction\": \"no_effect\",\n  \"limitations\": [\n    \"Sample size not reported in the provided abstract/metadata\",\n    \"Outcome assessment described for toe-spread/walking function; other potential regeneration endpoints not reported in the provided abstract\",\n    \"Exposure described as whole-body; tissue-specific dosimetry beyond induced electric field estimates not detailed in the provided abstract\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"electromagnetic fields\",\n    \"ELF\",\n    \"bipolar rectangular pulse\",\n    \"solenoid coil\",\n    \"whole-body exposure\",\n    \"sciatic nerve crush\",\n    \"peripheral nerve regeneration\",\n    \"toe-spread\",\n    \"walking function\",\n    \"rat model\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/17265446/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=5076",
  "updated": "2026-02-14 08:13:14"
}