{
  "id": 5083,
  "url": "https://nnemf.org/research/5083-a-preliminary-study-of-oscillating-electromagnetic-field-effects",
  "title": "A preliminary study of oscillating electromagnetic field effects on human spermatozoon motility.",
  "authors": [
    "R Iorio",
    "R Scrimaglio",
    "E Rantucci",
    "S Delle Monache",
    "A Di Gaetano",
    "N Finetti",
    "F Francavilla",
    "R Santucci",
    "E Tettamanti",
    "R Colonna"
  ],
  "journal": "Bioelectromagnetics",
  "year": "2007",
  "doi": "10.1002/bem.20278",
  "pmid": "17019728",
  "abstract": "Some effects of extremely low frequency electromagnetic fields (ELF-EMFs) on human spermatozoa are reported. Significant increases in the values of the motility and of the other kinematic parameters have been observed when spermatozoa were exposed to an ELF-EMF with a square waveform of 5 mT amplitude and frequency of 50 Hz. By contrast, a 5 mT sine wave (50 Hz) and a 2.5 mT square wave (50 Hz) exposure did not produce any significant effect on sperm motility. The effects induced by ELF-EMF (50 Hz; 5 mT) during the first 3 h of exposure persisted for 21 h after the end of the treatment. These results indicate that ELF-EMF exposure can improve spermatozoa motility and that this effect depends on the field characteristics.",
  "effect": "mixed",
  "evidence": "very_low",
  "extraction": {
    "studyType": "in_vitro",
    "studyTypeLabel": "In vitro study",
    "effectDirection": "mixed",
    "evidenceLabel": "Very low",
    "population": "Human spermatozoa",
    "sampleSize": "—",
    "exposure": "ELF · 0.05 MHz · first 3 h of exposure; effects persisted for 21 h after end of treatment",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "Exposure to a 50 Hz ELF-EMF with a 5 mT square waveform significantly increased sperm motility and other kinematic parameters. No significant effects on sperm motility were observed with a 5 mT sine wave (50 Hz) or a 2.5 mT square wave (50 Hz). Effects from 50 Hz, 5 mT exposure during the first 3 h persisted for 21 h after treatment ended.",
    "outcomes": [
      "Spermatozoon motility",
      "Kinematic parameters of sperm motility"
    ],
    "limitations": [
      "Sample size not reported in abstract",
      "Study described as preliminary",
      "In vitro study on spermatozoa",
      "generalizability to in vivo fertility outcomes not addressed in abstract",
      "Exposure conditions varied by waveform and amplitude",
      "not all conditions showed effects"
    ],
    "keywords": [
      "extremely low frequency",
      "ELF-EMF",
      "50 Hz",
      "millitesla",
      "square waveform",
      "sine wave",
      "human spermatozoa",
      "motility",
      "kinematic parameters"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"in_vitro\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": null,\n    \"frequency_mhz\": 0.05,\n    \"sar_wkg\": null,\n    \"duration\": \"first 3 h of exposure; effects persisted for 21 h after end of treatment\"\n  },\n  \"population\": \"Human spermatozoa\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Spermatozoon motility\",\n    \"Kinematic parameters of sperm motility\"\n  ],\n  \"main_findings\": \"Exposure to a 50 Hz ELF-EMF with a 5 mT square waveform significantly increased sperm motility and other kinematic parameters. No significant effects on sperm motility were observed with a 5 mT sine wave (50 Hz) or a 2.5 mT square wave (50 Hz). Effects from 50 Hz, 5 mT exposure during the first 3 h persisted for 21 h after treatment ended.\",\n  \"effect_direction\": \"mixed\",\n  \"limitations\": [\n    \"Sample size not reported in abstract\",\n    \"Study described as preliminary\",\n    \"In vitro study on spermatozoa; generalizability to in vivo fertility outcomes not addressed in abstract\",\n    \"Exposure conditions varied by waveform and amplitude; not all conditions showed effects\"\n  ],\n  \"evidence_strength\": \"very_low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"extremely low frequency\",\n    \"ELF-EMF\",\n    \"50 Hz\",\n    \"millitesla\",\n    \"square waveform\",\n    \"sine wave\",\n    \"human spermatozoa\",\n    \"motility\",\n    \"kinematic parameters\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/17019728/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=5083",
  "updated": "2026-02-14 08:13:18"
}