  "id": 5229,
  "url": "https://nnemf.org/research/5229-acute-effects-of-low-frequency-electromagnetic-fields-on",
  "title": "Acute effects of low-frequency electromagnetic fields on leukocyte-endothelial interactions in vivo.",
  "authors": [
    "Akira Ushiyama",
    "Chiyoji Ohkubo"
  ],
  "journal": "In vivo (Athens, Greece)",
  "year": "2004",
  "doi": null,
  "pmid": "15113039",
  "abstract": "BACKGROUND: To clarify the effect of extremely low frequency electromagnetic field (ELF-EMF) on the microcirculatory system, acute effects on leukocyte-endothelium interactions resulting from ELF-EMF exposure were examined with conscious BALB/c mice by means of a dorsal skinfold chamber. MATERIALS AND METHODS: The fluorescent dye, rhodamine 6G, was injected into the caudal vein to visualize leukocytes in vivo and to analyze leukocyte-endothelium interactions. Mice were exposed in vivo to 50 Hz linear sinusoidal wave EMF at magnetic flux densities of 3, 10 or 30 mT, for 30 minutes. RESULTS: The mean velocity of free flowing leukocytes in the center stream of venules revealed no distinct changes following exposure. However, at a flux density of 30 mT, the number of adherent leukocytes, defined as the total number of rolling and endothelium-adhering leukocytes, increased significantly following ELF-EMF exposure (p<0.05); no significant differences in adherent cell numbers were found in the 3 mT and 10 mT exposure groups or sham controls comparing pre- and post-exposure periods. CONCLUSION: These results demonstrated that high magnetic flux densities of ELF-EMF had an effect on leukocyte-endothelium interactions and indicated that a threshold level for this phenomenon exists in the range of 10-30 mT under these experimental conditions.",
  "effect": "mixed",
  "evidence": "low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "mixed",
    "evidenceLabel": "Low",
    "population": "Conscious BALB/c mice (dorsal skinfold chamber model)",
    "sampleSize": "—",
    "exposure": "ELF · 0.05 MHz · 30 minutes",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "Exposure to 50 Hz sinusoidal EMF at 30 mT for 30 minutes significantly increased the number of adherent leukocytes (rolling + endothelium-adhering) compared with pre-exposure (p<0.05). No distinct changes were observed in mean velocity of free-flowing leukocytes, and no significant differences in adherent leukocyte numbers were found at 3 mT or 10 mT or in sham controls.",
    "outcomes": [
      "Leukocyte velocity in venules (free-flowing leukocytes)",
      "Number of adherent leukocytes (rolling + endothelium-adhering)",
      "Leukocyte-endothelium interactions in vivo"
    ],
    "limitations": [
      "Sample size not reported in the abstract",
      "Acute exposure only (30 minutes)",
      "no longer-term outcomes reported",
      "Animal model",
      "generalizability to humans not addressed",
      "Exposure source/setup details beyond waveform",
      "frequency",
      "and flux density not provided in the abstract"
    ],
    "keywords": [
      "extremely low frequency",
      "ELF-EMF",
      "50 Hz",
      "magnetic flux density",
      "3 mT",
      "10 mT",
      "30 mT",
      "microcirculation",
      "leukocyte-endothelial interactions",
      "rolling",
      "adhesion",
      "dorsal skinfold chamber",
      "BALB/c mice"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": null,\n    \"frequency_mhz\": 0.05,\n    \"sar_wkg\": null,\n    \"duration\": \"30 minutes\"\n  },\n  \"population\": \"Conscious BALB/c mice (dorsal skinfold chamber model)\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Leukocyte velocity in venules (free-flowing leukocytes)\",\n    \"Number of adherent leukocytes (rolling + endothelium-adhering)\",\n    \"Leukocyte-endothelium interactions in vivo\"\n  ],\n  \"main_findings\": \"Exposure to 50 Hz sinusoidal EMF at 30 mT for 30 minutes significantly increased the number of adherent leukocytes (rolling + endothelium-adhering) compared with pre-exposure (p<0.05). No distinct changes were observed in mean velocity of free-flowing leukocytes, and no significant differences in adherent leukocyte numbers were found at 3 mT or 10 mT or in sham controls.\",\n  \"effect_direction\": \"mixed\",\n  \"limitations\": [\n    \"Sample size not reported in the abstract\",\n    \"Acute exposure only (30 minutes); no longer-term outcomes reported\",\n    \"Animal model; generalizability to humans not addressed\",\n    \"Exposure source/setup details beyond waveform, frequency, and flux density not provided in the abstract\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"extremely low frequency\",\n    \"ELF-EMF\",\n    \"50 Hz\",\n    \"magnetic flux density\",\n    \"3 mT\",\n    \"10 mT\",\n    \"30 mT\",\n    \"microcirculation\",\n    \"leukocyte-endothelial interactions\",\n    \"rolling\",\n    \"adhesion\",\n    \"dorsal skinfold chamber\",\n    \"BALB/c mice\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/15113039/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=5229",
  "updated": "2026-02-14 08:16:04"
}