  "id": 5378,
  "url": "https://nnemf.org/research/5378-effects-of-an-elf-50-hz-1-mt",
  "title": "Effects of an ELF (50 Hz, 1 mT) electromagnetic field (EMF) on concentration in visual attention, perception and memory including effects of EMF sensitivity.",
  "authors": [
    "M Trimmel",
    "E Schweiger"
  ],
  "journal": "Toxicology letters",
  "year": "1998",
  "doi": "10.1016/s0378-4274(98)00096-4",
  "pmid": "9820691",
  "abstract": "To investigate psychological effects of an extremely low frequency (ELF)-electromagnetic field (EMF), an experiment with three conditions was designed. EMF field of 50 Hz and 1 mT accompanied by 45 dB SPL noise (EMF + noise), noise, and control. A group of 66 subjects (Ss) participated in the control and in one of the experimental conditions. The sequence of conditions (expositions) was balanced. Expositions were double-blind (except for the obvious control), lasted 1 h and were separated by a 1 h pause. During exposition Ss (three by three) performed tests on attention, perception, memory and filled out a psychological questionnaire. Statistical analysis (one-tailed probability) showed less attention (P < 0.05), perception (P < 0.05) and memory performance (P < 0.1) in Ss exposed to EMF + noise compared with control, whereas for noise versus control no difference was found. Comparing EMF + noise versus noise related to control, reduced perception, less memory performance and more discomfort was observed (P < 0.1). Dividing Ss according to their self-rated sensitivity to EMF, all differences disappeared in the low sensitivity group (N = 30) and were pronounced in sensitive Ss (N = 36). Results indicate an immediate reduction of cognitive performance in attention, perception and memory performance by a 50 Hz EMF of 1 mT. These effects seem to be modulated by the self-perception of sensitivity to EMF.",
  "effect": "mixed",
  "evidence": "low",
  "extraction": {
    "studyType": "other",
    "studyTypeLabel": "Other",
    "effectDirection": "mixed",
    "evidenceLabel": "Low",
    "population": "Human subjects",
    "sampleSize": "66",
    "exposure": "ELF · 0.05 MHz · 1 h",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "In a double-blind experiment with three conditions (EMF+noise, noise, control), participants exposed to 50 Hz, 1 mT EMF accompanied by 45 dB SPL noise showed reduced attention and perception (P<0.05) and reduced memory performance (P<0.1) versus control; noise alone did not differ from control. When stratified by self-rated EMF sensitivity, differences disappeared in the low-sensitivity group (N=30) and were more pronounced in sensitive participants (N=36).",
    "outcomes": [
      "Attention (visual attention/concentration)",
      "Perception",
      "Memory performance",
      "Discomfort (questionnaire)",
      "Self-rated EMF sensitivity (effect modifier)"
    ],
    "limitations": [
      "Exposure condition combined EMF with noise (EMF+noise)",
      "complicating attribution to EMF alone",
      "Control condition not blinded (\"obvious control\")",
      "Statistical analysis used one-tailed probability",
      "Some reported effects were only marginal (e.g.",
      "P<0.1)",
      "Participants were tested in groups of three during exposure"
    ],
    "keywords": [
      "ELF",
      "50 Hz",
      "1 mT",
      "noise",
      "double-blind",
      "attention",
      "perception",
      "memory",
      "cognitive performance",
      "EMF sensitivity",
      "discomfort"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Study involves ELF (50 Hz) exposure at 1 mT, relevant to contexts where such fields may occur, though no specific setting is stated."
      }
    ],
    "raw": "{\n  \"study_type\": \"other\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": null,\n    \"frequency_mhz\": 0.05,\n    \"sar_wkg\": null,\n    \"duration\": \"1 h\"\n  },\n  \"population\": \"Human subjects\",\n  \"sample_size\": 66,\n  \"outcomes\": [\n    \"Attention (visual attention/concentration)\",\n    \"Perception\",\n    \"Memory performance\",\n    \"Discomfort (questionnaire)\",\n    \"Self-rated EMF sensitivity (effect modifier)\"\n  ],\n  \"main_findings\": \"In a double-blind experiment with three conditions (EMF+noise, noise, control), participants exposed to 50 Hz, 1 mT EMF accompanied by 45 dB SPL noise showed reduced attention and perception (P<0.05) and reduced memory performance (P<0.1) versus control; noise alone did not differ from control. When stratified by self-rated EMF sensitivity, differences disappeared in the low-sensitivity group (N=30) and were more pronounced in sensitive participants (N=36).\",\n  \"effect_direction\": \"mixed\",\n  \"limitations\": [\n    \"Exposure condition combined EMF with noise (EMF+noise), complicating attribution to EMF alone\",\n    \"Control condition not blinded (\\\"obvious control\\\")\",\n    \"Statistical analysis used one-tailed probability\",\n    \"Some reported effects were only marginal (e.g., P<0.1)\",\n    \"Participants were tested in groups of three during exposure\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"ELF\",\n    \"50 Hz\",\n    \"1 mT\",\n    \"noise\",\n    \"double-blind\",\n    \"attention\",\n    \"perception\",\n    \"memory\",\n    \"cognitive performance\",\n    \"EMF sensitivity\",\n    \"discomfort\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.25,\n      \"reason\": \"Study involves ELF (50 Hz) exposure at 1 mT, relevant to contexts where such fields may occur, though no specific setting is stated.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/9820691/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=5378",
  "updated": "2026-02-14 08:19:48"
}