  "id": 542,
  "url": "https://nnemf.org/research/542-liver-tissues-oxidative-status-epigenetic-and-molecular-characteristics",
  "title": "Liver tissues oxidative status, epigenetic and molecular characteristics in rats administered magnetic and microwave treated water",
  "authors": [],
  "journal": "",
  "year": "2023",
  "doi": "10.1038/s41598-023-31168-9",
  "pmid": null,
  "abstract": "Liver tissues oxidative status, epigenetic and molecular characteristics in rats administered magnetic and microwave treated water Elmoslemany AM, Ghamry HI, Awad AA, El-Kholy RI, Almami ISM, Alyamani NM, Zedan AMG. Liver tissues oxidative status, epigenetic and molecular characteristics in rats administered magnetic and microwave treated water. Sci Rep. 2023 Mar 16;13(1):4406. doi: 10.1038/s41598-023-31168-9. Abstract Physical and chemical changes in the natural of water may affect biological organisms. In this study, we highlight the effect of magnetized-water and microwave-water on rats' liver tissues. Three groups of albino rats were separated. The first, rats were administered tap-water. The second, rats were administered magnetized-water. The third, rats were administered microwave-water. After two months, the results revealed a significant increase in liver functioning enzymes' levels and bilirubin in rats administered microwave-water, compared to tap- and magnetic-water. In relation to oxidative stress, there was a significant increase and decrease in oxidative and antioxidant parameters respectively in liver tissues of rat's administrated microwave-water. At the molecular level, there was a significant down-regulation in Metallothionein, CYP genes in magnetic-water compared to tap-water. Rats administered microwave-water have shown a significant down-regulation in GST, Metallothionein and CYP genes' expression, however, Amylase and HDAC3 genes were significantly up- regulated, compared to the other groups. The intake of microwave-water resulted in notable histopathological changes in liver tissues. Rats administered magnetic-water showed no clear changes in their liver tissues. In summary, microwave-water induced stress and epigenetic effects compared with magnetic-water and tap- water. Also, magnetic-water produced from the higher magnetic power had no side effect on liver tissues. : https://www.nature.com/articles/s41598-023-31168-9",
  "effect": "harm",
  "evidence": "low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "harm",
    "evidenceLabel": "Low",
    "population": "albino rats",
    "sampleSize": "—",
    "exposure": "microwave treated water; magnetized water · 2 months",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "After two months, rats administered microwave-treated water showed significantly increased liver function enzymes and bilirubin versus tap- and magnetized-water groups. Microwave-water was associated with increased oxidative parameters and decreased antioxidant parameters in liver tissue, down-regulation of GST/Metallothionein/CYP genes and up-regulation of Amylase and HDAC3, along with notable liver histopathological changes; magnetized-water showed no clear liver tissue changes.",
    "outcomes": [
      "Liver function enzymes levels",
      "Bilirubin",
      "Oxidative stress parameters in liver tissue (oxidative and antioxidant parameters)",
      "Gene expression (Metallothionein",
      "CYP",
      "GST",
      "Amylase",
      "HDAC3)",
      "Histopathological changes in liver tissue"
    ],
    "limitations": [
      "Sample size not reported in abstract",
      "Microwave and magnetic treatment parameters (e.g.",
      "frequency",
      "field strength",
      "exposure metrics) not reported in abstract",
      "Details of oxidative/antioxidant markers and assay methods not provided in abstract"
    ],
    "keywords": [
      "microwave-treated water",
      "magnetized water",
      "rats",
      "liver",
      "oxidative stress",
      "antioxidant parameters",
      "gene expression",
      "epigenetic",
      "HDAC3",
      "histopathology"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": null,\n    \"source\": \"microwave treated water; magnetized water\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"2 months\"\n  },\n  \"population\": \"albino rats\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Liver function enzymes levels\",\n    \"Bilirubin\",\n    \"Oxidative stress parameters in liver tissue (oxidative and antioxidant parameters)\",\n    \"Gene expression (Metallothionein, CYP, GST, Amylase, HDAC3)\",\n    \"Histopathological changes in liver tissue\"\n  ],\n  \"main_findings\": \"After two months, rats administered microwave-treated water showed significantly increased liver function enzymes and bilirubin versus tap- and magnetized-water groups. Microwave-water was associated with increased oxidative parameters and decreased antioxidant parameters in liver tissue, down-regulation of GST/Metallothionein/CYP genes and up-regulation of Amylase and HDAC3, along with notable liver histopathological changes; magnetized-water showed no clear liver tissue changes.\",\n  \"effect_direction\": \"harm\",\n  \"limitations\": [\n    \"Sample size not reported in abstract\",\n    \"Microwave and magnetic treatment parameters (e.g., frequency, field strength, exposure metrics) not reported in abstract\",\n    \"Details of oxidative/antioxidant markers and assay methods not provided in abstract\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"microwave-treated water\",\n    \"magnetized water\",\n    \"rats\",\n    \"liver\",\n    \"oxidative stress\",\n    \"antioxidant parameters\",\n    \"gene expression\",\n    \"epigenetic\",\n    \"HDAC3\",\n    \"histopathology\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://www.nature.com/articles/s41598-023-31168-9",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=542",
  "updated": "2026-02-10 10:34:42"
}