EMF biological effects
Share

Exposure of baboons to combined 60 Hz electric and magnetic fields does not produce work stoppage or affect operant performance on a match-to-sample task.

J L Orr, W R Rogers, H D Smith

PAPERpubmedBioelectromagnetics1995Animal studyEffect: no_effectEvidence: Low

Abstract

We examined the effects of combined 60 Hz electric and magnetic field (EMF) exposure on performance of delayed match-to-sample (MTS) procedure involving the flash rate of a light as the stimulus. Six baboons (Papio cynocephalus) fully acquired the task; four others functioned accurately only when cued. All ten subjects were assigned to EMF-exposed or sham-exposed groups of five and were used to test for a work-stoppage effect that was previously observed with initial exposure to electric fields (EF) of 30 or 60 kV/m. Here, we report the results of two experiments, each consisting of 6 week preexposure, exposure, and postexposure periods. We found no evidence of work stoppage with fields of 6 kV/m and 50 microT (0.5 G) or with 30 kV/m and 100 microT (1.0 G). In neither experiment was there evidence of an adverse effect of 60 Hz EMF exposure on MTS performance.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
no_effect
Population
Baboons (Papio cynocephalus)
Sample size
10
Exposure
ELF · 0.06 MHz · Two experiments; each had 6-week preexposure, exposure, and postexposure periods (exposure duration not further specified).
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Across two experiments, there was no evidence of work stoppage at 6 kV/m with 50 microT (0.5 G) or at 30 kV/m with 100 microT (1.0 G). No adverse effects of 60 Hz combined electric and magnetic field exposure were observed on MTS task performance.

Outcomes measured

  • Work stoppage
  • Operant performance on delayed match-to-sample (MTS) task (flash rate of a light as stimulus)

Limitations

  • Small sample size (10 baboons
  • 5 exposed and 5 sham per experiment/grouping as described)
  • Exposure duration within the exposure period not specified in the abstract
  • Some animals required cueing to perform accurately
  • which may affect generalizability of performance outcomes

Suggested hubs

  • occupational-exposure (0.7)
    Study examines combined 60 Hz electric and magnetic fields at kV/m and microtesla levels relevant to power-frequency environments, though no specific workplace setting is stated.
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "ELF",
    "source": null,
    "frequency_mhz": 0.06,
    "sar_wkg": null,
    "duration": "Two experiments; each had 6-week preexposure, exposure, and postexposure periods (exposure duration not further specified)."
  },
  "population": "Baboons (Papio cynocephalus)",
  "sample_size": 10,
  "outcomes": [
    "Work stoppage",
    "Operant performance on delayed match-to-sample (MTS) task (flash rate of a light as stimulus)"
  ],
  "main_findings": "Across two experiments, there was no evidence of work stoppage at 6 kV/m with 50 microT (0.5 G) or at 30 kV/m with 100 microT (1.0 G). No adverse effects of 60 Hz combined electric and magnetic field exposure were observed on MTS task performance.",
  "effect_direction": "no_effect",
  "limitations": [
    "Small sample size (10 baboons; 5 exposed and 5 sham per experiment/grouping as described)",
    "Exposure duration within the exposure period not specified in the abstract",
    "Some animals required cueing to perform accurately, which may affect generalizability of performance outcomes"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "60 Hz",
    "ELF",
    "electric field",
    "magnetic field",
    "baboons",
    "Papio cynocephalus",
    "work stoppage",
    "operant performance",
    "delayed match-to-sample"
  ],
  "suggested_hubs": [
    {
      "slug": "occupational-exposure",
      "weight": 0.25,
      "reason": "Study examines combined 60 Hz electric and magnetic fields at kV/m and microtesla levels relevant to power-frequency environments, though no specific workplace setting is stated."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 5444

Exposure of baboons to combined 60 Hz electric and magnetic fields does not produce work stoppage or affect operant performance on a match-to-sample task. · Non-native EMF